  • Page 1 User Guide for 86002 Inverter Generator 2300 Watt, Rated 1800 Watt...
  • Page 2: Table Of Contents

    Table of Contents Parts List...............2 Maintenance............18 Maintenance Schedule........18 Introduction............3 Checking Spark Plug........19 Product Specifications........3 Changing Oil..........19-20 Customer Service ..........3 How to Clean Air Filter........20 Checking Muffler and Spark Arrestor....21 Safety Rules............3-6 How to Clean Fuel Filter........22 Safety Symbols..........3 Transport & Storage........22-23 Safety Instructions..........4-6 Control Panel Functions........7-9 Troubleshooting..........24...
  • Page 3: Parts List

    Parts List Spark Plug Cover USB Outlet 5VDC 1.5A Recoil Starter Spark Arrestor 120V AC 15A Duplex Outlet Control Panel Parallel Outlets Muffler Cover Oil Warning Light Indicator Ground Terminal Outer Casing (Side Panel) Overload Indicator Light Circuit Breaker AC Handle AC Pilot Light Air Vent...
  • Page 4: Introduction

    Introduction Thank you for purchasing this 2300 watt portable Save your original sales receipt and record the inverter generator from JEGS. This generator is following information below for service or warranty designed to give you years of reliable service when assistance.
  • Page 5: Safety Rules

    Safety Rules The engine exhaust contains chemicals The manufacturer cannot anticipate every possible circumstance that the user may encounter hazards. that can cause cancer and birth defects. Therefore, the warnings in this manual, on tags, • Always wash hands after handling generator. and on affixed decals are not all-inclusive.
  • Page 6 Safety Rules Cont. Keep away from flammable objects Avoid touching hot areas of this unit. and other hazardous materials. • Only operate the generator on a level surface. • The fuel and its vapors used to power this unit • If connected to a structure, connect the ground are highly flammable and could explode resulting terminal to an appropriate ground.
  • Page 7 Safety Rules Cont. Only use as intended. Used incorrectly, serious injury or death could result. • Do not bypass any safety device. Moving parts are covered with guards. Make sure all protective covers are in place. • Never transport or make adjustments to this unit while it is running.
  • Page 8: Control Panel Functions

    Control Panel Functions ON/OFF Start Switch and Choke Start Switch “OFF” When the Start Switch is in the “OFF” position the fuel valve is switched off and the engine will not run. Start Switch “CHOKE” When the Start Switch is in the “CHOKE” position the fuel valve is switched on and the engine can be started.
  • Page 9: Dc Protector

    Control Panel Functions Cont. Engine Overload Indicator Light in the “OFF” position, the generator will no longer supply power. The DC Circuit Breaker automatically If the engine overload indicator light comes on, the turns “OFF” when connecting electronic devices generator’s wattage / amperage capacity has been to the generator that exceed the generator’s rated exceeded by connected electrical devices or by a output.
  • Page 10: Parallel Outlets

    • Only operate generator on a level surface. • Always connect the nut and ground terminal on • Only connect to another 86002 Generator. the frame to an appropriate ground source. • Only use a parallel operation cable kit designed to work with this generator.
  • Page 11: Assembly

    Assembly Connecting the Generator Adding Fuel to an Electrical System • Set generator outdoors in a well-ventilated area, If you are connecting the generator to a building’s away from structures and people. electrical system for standby power, you must use •...
  • Page 12: Adding / Checking Oil

    Assembly Cont. Adding and Checking Engine Oil (crankcase dipstick hole). • Be sure to replace dipstick and securely tighten • Place generator on a level surface. before attempting to start the engine. • Remove screws and then remove the outer •...
  • Page 13: Operation

    Operation Grounding the Generator To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel Functions on page 9. Standard Atmospheric Conditions • Ambient Temperature: 77º F (25º C) • Barometric Pressure: 100 kPa •...
  • Page 14: How To Stop Engine

    Operation Cont. Note: Steps to start the generator with the Economy switch in the “ON” position • Disconnect all electrical loads from generator. • Start the engine. • If ambient temperature is below 32ºF (0ºC) allow about 3 minutes for the engine to warm up. •...
  • Page 15: Attaching Electronic Devices

    Operation Cont. How to Attach Electronic Devices 2. Clean battery terminals with a brush if corroded. 3. Securely connect the red cable clamp to the 1. Before Starting generator positive (+) battery terminal. • Make sure the generator is grounded (see 4.
  • Page 16: Ac Parallel Operation

    2-3 seconds. When an electronic device is started, the red overload indicator may come It is possible to connect two 86002 generators to on. This is normal. If the light stays on disconnect all electronic devices and stop the engine. Refer to each other, using a parallel cable kit, to increase available power output.
  • Page 17: Do Not Overload Generator

    Never connect generators that are different models. • Only connect to another 86002 Generator. • Only use a JEGS approved parallel operation cable kit to connect generators. • Never exceed maximum power , this setup may be used for no more than 30 minutes.
  • Page 18: Wattage Reference Guide

    Operation Cont. Wattage Reference Guide (Wattages listed are approximate. Check electrical devices for actual wattage.) Rated Watts Surge Watts Rated Watts Essentials Family Room Surge Watts 75 W Light Bulbs 75 ea. 75 ea. X-Box or PlayStation 18 Cu. Ft. Refrigerator 2200 AM/FM Radio Furnace Fan (...
  • Page 19: Maintenance

    Maintenance Regular maintenance will extend the life of this After First 5 Hours Change engine oil generator and improve its performance. The warranty After 8 Hours Clean debris from generator does not cover items that result from operator abuse, or Daily and air filter area misuse, or negligence.
  • Page 20: Checking Spark Plug

    Maintenance Cont. • If spark plug is worn, replace only with an equivalent type. Spark plug should be replaced annually regardless of apparent condition. • Reconnect spark plug wire, firmly, until it clicks into place. Standard Spark Plug • Torch F7TC/F7RTC Spark Plug Gap •...
  • Page 21: How To Clean Air Filter

    Maintenance Cont. Air Filter A dirty air filter will reduce the lifespan of th engine, make it difficult to start and reduce performance. Replace with a new filter annually. • To clean, remove the screws then remove outer casing. • Remove the screws then remove air filter cover. •...
  • Page 22: Checking Muffler And Spark Arrestor

    Maintenance Cont. Checking Muffler and Spark Arrester • Inspect the muffler for cracks, corrosion, or other damage. • Remove screws, then remove the muffler cover as shown. • Loosen bolt, then remove muffler cap, muffler screen, and spark arrester. • Check the muffler screen and spark arrester for carbon deposits.
  • Page 23: How To Clean Fuel Filter

    Maintenance Cont. Transport & Storage Fuel Tank Filter Fuel Filter • To clean, remove fuel cap and filter. • To clean, remove screws, remove outer casing, • Clean filter with gasoline. and drain fuel. • Wipe the filter with a clean rag. •...
  • Page 24 Transport & Storage Cont. Engine Long-Term Storage Contact with a hot engine or exhaust system can cause serious burns or fires. • Remove the spark plug and pour about 1 tsp. Let the engine cool before transporting or storing the generator. of 10W-30 engine oil into the spark plug hole.
  • Page 25: Troubleshooting

    Troubleshooting Problem Cause Solution Generator is running, but 1. DC circuit breaker is “Off” 1. Turn DC circuit breaker “On” does not supply power. 2. Green AC pilot indicator 2. Stop engine and restart light is off 3. Check and repair 3.
  • Page 26: Specifications

    Specifications Type Inverter Rated Frequency 60Hz Rated Voltage 120V Maximum Output Power 2.3kW Rated Output Power 1.8kW Generator Power Factor AC Output Quality ISO8528 G1 THD% <3 DC Output 12V/8A Overload Protect Engine Type Single Cylinder, 4-Stroke, Forced Air Cooling, OHV Displacement (cc) Engine Fuel Type...