PREVOST X3-45 2016 Maintenance Manual page 179

Table of Contents

Advertisement

REAR JUNCTION BOX MODULES
MID 188 PSID # 224 A49 MODULE NO RESPONSE
Type of
FMI
fault:
Description:
FMI 2
Data Error
MID 188 PSID # 225 A50 MODULE NO RESPONSE
Type of
FMI
fault:
Description:
FMI 2
Data Error
MID 188 PSID # 226 A51 MODULE NO RESPONSE
Type of
FMI
fault:
Description:
FMI 2
Data Error
MID 188 PSID # 227 A52 MODULE NO RESPONSE
Type of
FMI
fault:
Description:
FMI 2
Data Error
MID 188 PSID # 228 A53 MODULE NO RESPONSE
Type of
FMI
fault:
Description:
FMI 2
Data Error
Fault Condition:
Possible
Symptoms:
A49 Module not
A49 module all
responding on CAN
inputs and outputs
network
not responding
Fault Condition:
Possible
Symptoms:
A50 Module not
A50 module all
responding on CAN
inputs and outputs
network
not responding
Fault Condition:
Possible
Symptoms:
A51 Module not
A51 module all
responding on CAN
inputs and outputs
network
not responding
Fault Condition:
Possible
Symptoms:
A52 Module not
A52 module all
responding on CAN
inputs and outputs
network
not responding
Fault Condition:
Possible
Symptoms:
A53 Module not
A53 module all
responding on CAN
inputs and outputs
network
not responding
SECTION 06C: ELECTRICAL
Possible Causes:
 CAN network open
 Address Jumper open circuit
 Fuse F65 defective
Possible Causes:
 CAN network open
 Address Jumper open circuit
 Fuse F72 defective
Possible Causes:
 CAN network open
 Address Jumper open circuit
 Fuse F80 defective
Possible Causes:
 CAN network open
 Address Jumper open circuit
 Fuse F65 defective
Possible Causes:
 CAN network open
 Address Jumper open circuit
 Fuse F65 defective
3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X3-45 2016 and is the answer not in the manual?