R&S
RTP
Query parameters:
<SearchName>
Return values:
<Start>
Usage:
SEARch:RESult:MPHY:FRAMe<m>:STOP? <SearchName>
Returns the end time for the selected frame within the search result.
Suffix:
<m>
Query parameters:
<SearchName>
Return values:
<Stop>
Usage:
22.17.15.6
Trigger USB SSIC (Option R&S RTP-K64)
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
●
TRIGger<m>:SOURce[:SELect]
●
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
●
Decoding is enabled:
There are two commands for each parameter, that you can use for defining the SSIC
trigger settings.
For example, to set the Frame type =ACK > Field =Route String >Data value you can
use one of the following commands:
●
TRIGger:MPHY:SSIC:FRAMe13:FLD1:DMIN 01100
Defines the parameter by using the index <m> for the frame number and <n> for
the field number.
●
TRIGger:MPHY:SSIC:DMIN "ACK", "Route String", 01100
Defines the parameter by using the frame and field name.
User Manual 1337.9952.02 ─ 12
Range:
-100E+24 to 100E+24
Increment: 100E-12
*RST:
0
Default unit: s
Query only
.
*
Range:
-100E+24 to 100E+24
Increment: 100E-12
*RST:
0
Default unit: s
Query only
is set to SBUS.
BUS<m>[:STATe]
Remote control commands
is set to ON.
Protocols