Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Reset position detection error on the stepper
E
6
1
3
0
iris initializing
Handshake correction function does not work
E
6
2
0
0
well. (With PITCH angular velocity sensor
output stopped.)
Handshake correction function does not work
E
6
2
0
1
well. (With YAW angular velocity sensor
output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller com-
E
6
2
0
3
munication abnormality among.
Image vibration correction during handshake
E
6
2
0
4
function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
9
1
0
1
Abnormality when flash is being charged.
E
9
1
0
2
Abnormality of LED Video light.
Abnormality of LED Video light Tempera-
E
9
1
0
3
ture detection.
Battery current value goes over the max
E
9
2
0
1
discharge current
Fault of writing or erasing the flash mem-
E
9
4
0
0
ory
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Note 4: After repair, be sure to perform "1-6. PROCESS AFTER FIXING FLASH ERROR".
HDR-CX220/CX220E/CX230/CX230E/CX280/CX280E/CX290/CX290E/CX320/CX320E/CX380/CX380E/CX390/CX390E/PJ220/PJ220E/PJ230/PJ230E/PJ320E/PJ380/PJ380E/PJ390/PJ390E_L2
Correction
Inspect the lens block zoom MR sensor signal (pin eg of CN1003 on
the VC-1010 board when zooming is performed when the zoom lever
is operated, and the zoom motor drive circuit (IC5501 on the VC-1010
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive
block (pin wg, wh of CN1003 on theVC-1010 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of "E: 61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
tween CN6702 on CM-1004 board and CN1008 on VC-1010 board
by FP-2059 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
Inspect PITCH angular velocity sensors (SE7501 on the MS-1004
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7501 on the MS-1004 board)
peripheral circuits.
Refer to "1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred".
Inspect the steadyshot circuit (IC5501 on the VC-1010 board).
Inspect the image vibration angular velocity sensors (SE7701 on the
VC-1010 board) peripheral circuits.
Replacement of lens block (Note 3).
If an error occurs again, replace the VC-1010 board.
Refer to "1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred".
Refer to "1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred".
Refer to "1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred".
Check or replace the LED Flash/Video light or charging capacitor.
(Note 4)
Check or replace the LED Flash/Video light or charging capacitor.
(Note 4)
Check or replace the LED Flash/Video light or charging capacitor.
(Note 4)
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each
output of DC/DC converter (IC4301 on the VC-1010 board) with
connected the DC JACK (J901) on the VC-1010 board.
(The minimum connection to periphery)
Inspect the flash memory (IC8101 on the MM-102 board).
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
E
9
4
0
1
Internal flash memory fault
E
9
4
0
2
BGM data error
E
9
5
0
0
GPS hardware error
*
E
9
6
0
0
*
Map area mount error
E
9
7
0
0
Projector hardware error
1-5. METHOD OF COPING WITH SHIFT LENS ERROR (CX28[]/CX29[]/CX3[][]/PJ3[][] Model)
VC-1010 BOARD (SIDE A)
Measurement points on the VC-1010 board
1-4
– ENGLISH –
Correction
Inspect the flash memory (IC8101 on the MM-102 board).
Check the CPU (IC1301 on the VC-1010 board).
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
IC5501
C5513
C5515
C5516
Fig. 1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDR-CX220 and is the answer not in the manual?

Questions and answers

Table of Contents