Page 1
Product Model # SAUQ-1105 Item # 3300181 1 Gallon Ultra Quiet Air Compressor OPERATOR’S MANUAL CAUTION: To Reduce The Risk Of Injury, User Must Read And Understand Operator’s Manual. Save These Instructions For Future Reference. 1-888-899-0146 Toll Free Helpline:...
SAFETY GUIDELINES Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method, or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others.
Page 4
SAFETY INFORMATION DO NOT OPERATE THIS UNIT UNTIL YOU READ AND UNDERSTAND THIS INSTRUCTION MANUAL FOR SAFETY, OPERATION, AND MAINTENANCE INSTRUCTIONS. WARNING Risk of fire caused by sparks from motor and pressure switch could result in death or serious injury. Do not operate compressor near flammable gas or vapor.
KEY PARTS DIAGRAM Electrical Motor Outlet Pressure Gauge Air Compressor Pump Quick Coupler Safety Valve Drain Valve ON/OFF Switch Air Tank Air Pressure Regulator Power Cord Tank Pressure Gauge Overload Protector...
Page 6
PARTS DESCRIPTION Electric Motor The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent the motor from being damaged.
ASSEMBLY INSTRUCTIONS Unpack the air compressor unit. Inspect the unit for damaged. If the unit has been damaged, contact the • retailer immediately. Check the air compressor’s identification label to ensure that you have purchased the intended model and • that it has the required pressure rating for its intended use.
OPERATING INSTRUCTIONS Break in the pump Fig C 1.Set the ON/OFF switch (1) to the OFF position (Fig C). 2.Open tank drain valve (1) by turning it counter-clockwise to permit the air to escape and prevent air pressure build-up in the air tank during the break-in period (Fig D). Fig D 3.Turn the air pressure regulator knob (1) clockwise until it stops (Fig E).
Page 9
OPERATING INSTRUCTIONS Before each start-up Fig H 1.Set the ON/OFF switch (1) to the OFF position (Fig H). 2.Turn the air pressure regulator knob (1) counter-clockwise until it stops (Fig I). Fig I 3.Attach hose and accessories (Fig J).(Hose and accessories need to be purchased Fig J separately.) How to start...
MAINTENANCE SERVICE ITEM DESCRIPTION / REASON INTERVAL Through normal operation of your air compressor, condensation of water will accumulate in the tank. To prevent corrosion of the tank from the inside, condensation must be drained at the end of every workday. Be sure to wear protective goggles.
TROUBLESHOOTING SOLUTIONS PROBLEM POSSIBLE CAUSE The power cord is not plugged in. Plug the power cord into a grounded outlet. The on/off switch is in the O (OFF) Set the on/off switch to the ON position. position. The extension cord is the wrong wire Check extension cord information for the proper gauge or is too long.
Page 12
TROUBLESHOOTING SOLUTIONS PROBLEM POSSIBLE CAUSE Check the fittings with soapy water. Tighten or There is a leak at one of the fittings. reseal leaking fittings (apply plumber s tape on threads).Do not over tighten. Close the drain valve. The tank drain valve is open. Clean or replace the air filter element.
STEALTH WARRANTY LIMITED LIFETIME WARRANTY ONLY THE PUMP AND MOTOR ARE COVERED IN THE LIFETIME WARRANTY Warranty covers any defects in materials or workmanship of the enclosed product. Alton Industry Ltd. Group will repair or replace any defective materials due to craftsmanship of the product.
Need help?
Do you have a question about the SAUQ-1105 and is the answer not in the manual?