Summary of Contents for Kollmorgen SERVOSTAR CD Series
Page 1
KOLLMORGEN www.DanaherMotion.com NOTICE DO NOT DISCARD In a continuing effort to satisfy our customers, Danaher Motion has provided this packet of instructions with your product. This information provides safety, warranty, and liability information. This information enables you, the customer to get this unit up and running with installation steps.
SAFETY Only qualified personnel are permitted to transport, assembly, commission, and maintenance this equipment. Properly qualified personnel are persons who are familiar with the transport, assembly, installation, commissioning and operation of motors, and who have the appropriate qualifications for their jobs.
EMI (electromagnetic interference) and immunity refers to the susceptibility levels of the equipment. Limits were derived from generic standards EN55081-2 and EN55082-2 for heavy industrial environments. The SERVOSTAR CD series of drives and BUS Modules have been tested for radiated emissions, conducted emissions, EFT, ESD, surge, conducted immunity, and radiated immunity. These tests have been done in accordance with EN55011, EN61000-4-2, ENV50140, IEC 1000-4-4, EN61000- 4-5, and ENV50141.
UNPACKING AND INSPECTING Open the box(es) and remove all the contents. Check to ensure there is no visible damage to any of the equipment. Electronic components in this amplifier are design hardened to reduce static sensitivity. However, proper procedures should be used when handling. WARNING Remove all packing material and equipment from the shipping container.
NPUT OWER ILTERING The SERVOSTAR CD electronic system components require EMI filtering in the input power leads to meet the conducted emission requirements for the industrial environment. This filtering blocks conducted- type emissions from exiting onto the power lines and provides a barrier for EMI on the power lines. Care must be taken to adequately size the system.
INSTALLATION These installation steps are designed to lead you through the proper installation and setup of a ® SERVOSTAR CD system. They were developed with the assumption that you have a fundamental understanding of basic electronics, computers, mechanics, and proper safety practices. However, you do not have to be an expert in motion control to install and operate the drive system.
ILTER AND ONDING IAGRAM Cabinet/Enclosure Back Plane Contactor, Fuses, Xfmr, XFMR etc. Controller I/O filter CNC / PLC / Controller filter Note 1 Routed to Routed to Input power enters enclosure from metal conduit. This Motors Motors eliminates the need for shielded input power cable. Note 2 Note 6 Feedback cable bonding is required for CE compliance.
INOUT ONNECTORS C1: Communications Connector C2: Feedback Connector Function Resolver Encoder Sine Encoder Shield Sine High REC (RXD) (RS232) Sine Low XMIT (TXD) (RS232) Shield Shield Shield Reserved DO NOT CONNECT Cosine High Common Cosine Low TxD+ (RS485) Shield Shield Shield TxD- (RS485) E5V Return E5V Return...
Page 13
Notes for DIP switch: The 10 position DIP switch is provided for drive DIP (Configuration) Switch configuration. The first 6 switches control Switch Function Settings communications parameters and are read only at Bit 0 of MultiDrop Address power up. Any changes in these settings will (LSB) require cycling the power.
LECTRICAL PECIFICATIONS Product Model Cx03* Cx06* Cx10 ) Nominal ? 10% Voltage (VAC 110 to 230 115 VAC 1? or 3? 3? only 230 VAC 1? or 3? 3? only Line Frequency 47-63 KVA at 115 VAC 0.44 (1?) 0.89 (1?) 2.4 (3? only) 0.6 (3?) 1.1 (3?)
BUS M ODULE LECTRICAL PECIFICATIONS NOT USED FOR SERIES 5. NOTE Product Model PA-LM Voltage (AC) Nom. ? 10% 110 to 120 Logic Input Power Max. Current 1? (A) Line Frequency 47-63 Internal Fuse (amps) (internal) +8 VDC Supply Voltage (VDC) +7.25 to +8.5 Logic Output +8 VDC Supply Current (amps)
IRMWARE PDATES NOT APPLICABLE FOR SERIES 5. NOTE If your unit has the following label: It requires firmware version 4.0.0 or higher. Other unit types will work with all firmware versions. Firmware version 4.0.0 and higher is not compatible with the older versions of IGNITE (firmware loading software).
RROR ODES Series 5 Error Codes Error Code Fault Message Fatal Non-Fatal LED Display .No Error .Power stage over temperature .Over voltage .Over current .External feedback fault .Resolver line break .RDC error .Sine Encoder init fail .A/B line break .Index line break .Illegal halls .C/D line break .A/B out of range...
Page 20
Series 5 Error Codes Error Code Fault Message Fatal Non-Fatal LED Display 37.02 MENCRES out of range 37.03 MENCOFF out of range 37.04 MSPEED out of range 37.05 MBEMF out of range 37.06 MJ out of range 37.07 ACC out of range 37.08 DEC out of range 37.09...
Series 5 Error Codes Error Code Fault Message Fatal Non-Fatal LED Display Warning: Limit sw not routed Move is pending Incorrect password Password protected Capture during Homing Homing during Capture Capture process not done Capture process not active Capture process not enabled ENCSTART while Aconfig EnDat comm error SERCOS test failure...
NON-FATAL ERROR CODES Error Message Possible Cause Err # No Error no error was recorded Unknown Command Undefined command Unknown Variable undefined variable name Checksum error error on comm. message checksum (ACKMODE 2) Drive Active drive needs to be inactive for the requested command or variable Drive Inactive drive needs to be active for the requested command or variable Value out of range...
Page 23
Error Message Possible Cause Err # Not available The requested variable value is not available; refer to the description of the variable to determine why. Drive is in Hold mode Motion was requested with the drive in Hold mode Limit Switch Hold Drive is in Hold mode due to limit switch being tripped Command Into Limit Requested motion is in direction of tripped limit switch...
Need help?
Do you have a question about the SERVOSTAR CD Series and is the answer not in the manual?
Questions and answers