Figure 2-6. Dp83Tc812 Configured As Master; Figure 2-7. Wake Pin In Pulled Up Position - Texas Instruments DP83TC812EVM-MC User Manual

Media converter evm
Table of Contents

Advertisement

Introduction
2.2.2.3 SMI Interface
DP83TC812 PHY_ID on EVM is 10
DP83867 PHY_ID on EVM is 01
After installing and enabling the USB2MDIO tool, power on the EVM and connect to the computer through the
micro-USB port. Verify communication on each PHY by reading register 0x0001.
DP83TC812 will read 0x1 = 0x0061 with no link partner and 0x1 = 0x0065 with a link partner connected
DP83867 will read 0x1 = 0x7949 with no link partner and 0x1 = 0x796D with a link partner connected
To enable analog loopback on the DP83TC812, write 0x0108 to address 0x0016
2.2.3 Master and Slave Mode Selection – DP83TC812
Master Mode
– Place shunt across pins 1 and 2 of J2 as demonstrated in figure below
Slave Mode
– Place shunt across pins 2 and 3 of J2
2.2.4 Wake Selection – DP83TC812
Place shunt in PU position at WAKE header shown to pull wake pin of DP83TC812.
Place shunt in GND position at WAKE header shown to pull down wake pin of DP83TC812.
Figure 2-7
shows jumper in PU position on header.
2.2.5 LED Indication
Look for LED_0 (D3 or D4) and LED_1 (D2) to illuminate when a link is successfully established on the
DP83TC812
Look for LED to illuminate on the RJ45 when a link is successfully established on the DP83867
LED_1 (D2) will blink for TX/RX activity
6
DP83TC812EVM-MC User's Guide
Note

Figure 2-6. DP83TC812 configured as Master

Figure 2-7. Wake pin in pulled up position

Copyright © 2022 Texas Instruments Incorporated
SNLU292A – NOVEMBER 2020 – REVISED MARCH 2022
Submit Document Feedback
www.ti.com