Advertisement

Quick Links

Produzione stufe e termostufe a pellets e
policombustibili
User Manual
Lia

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lia and is the answer not in the manual?

Questions and answers

Summary of Contents for PASIAN Lia

  • Page 1 Produzione stufe e termostufe a pellets e policombustibili User Manual...
  • Page 3 user manual In this space it is advisable to mark the data of the stove, in this way you can always have a reference in case of request. Model N°serial number Dealer Purchase date...
  • Page 4: Table Of Contents

    MANUALE UTENTE USO E MANUTENZIONE INDICE 1. IINTRODUCTION....................1.1 SAFETY WARNINGS..............1.2 GENERAL SAFETY RULES....................INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT 1.4 FUELS................2. GENERAL DESCRIPTIONS..................2.1 PACKAGING CONTENT................2.2 OPERETING WARNINGS................2.3 POSITIONING AND ASSEMBLY ........2.4 AIR INLET....................
  • Page 5: Iintroduction

    We recommend that you take care of this manual and keep it. The images and figures in this manual are purely illustrative. Pasian also reserves the right to make changes at any time and without notice to the contents of this manual.
  • Page 6: General Safety Rules

    MANUALE UTENTE USO E MANUTENZIONE 1.2 GENERAL SAFETY RULES Before using the appliance, carefully read this use and maintenance manual in all its parts. The installation and use of the product must be done in accordance with the manufacturer's instructions, and in compliance with national and local regulations. Installation, electrical connection, validation, maintenance and repairs are operations that must be carried out exclusively by qualified, authorized personnel with adequate knowledge of the product.
  • Page 7: Information For The Correct Disposal Of The Product

    Pasian both in civil law from all responsibility. The user is responsible for all the operations necessary for maintaining the efficiency of the equipment before and during its use.
  • Page 8: Fuels

    1.4 FUELS Pasian production was created to fully satisfy the needs of heating and practicality, with our products, you can use pellets, washed and cleaned pits, corn mixed with pellets, shells, without making structural changes to the stove, but with the use of the appropriate braziers, supplied with it (see figure a) and b)) The use of different fuels is subject to the intervention of the authorized technician for product calibration.
  • Page 9: General Descriptions

    user manual 2. GENERAL DESCRIPTIONS 2.1 PACKAGING CONTENT Dear customer, the stove you purchased is related to: Pellet burner with diverter b) Nocciolino burner without diverter c) Deflectors d) ash drawer e) electrical cable f) controller g) user manual ATTENTION: the shape and aesthetic characteristics of the various components may suffer variations.
  • Page 10: Opereting Warnings

    Pasian declines all responsibility in the event of installations that do not comply with the laws in force, of an incorrect local air exchange, of an electrical connection that does not comply with the regulations and of inappropriate use of the stove.
  • Page 11: Air Inlet

    user manual fig. c During installation it is advisable to respect the distances indicated (figure c) and to remember that maintenance interventions can also take place on the rear side, which must never be blocked.: matchboards, furniture, curtains, paintings, sofas), the minimum distances illustrated (figure c) must be respected, wooden beams and finishes, sofas or furniture must be placed outside the radiant area of ​...
  • Page 12: Iinstallation Of The Chimney

    user manual 2.5 INSTALLATION OF THE CHIMNEY The flue is of great importance for the regular functioning of a forced draft solid fuel heating appliance, its installation is a very important operation for the functioning of the stove, it is therefore essential that the flue is built at state of the art and always kept in perfect efficiency.
  • Page 13 user manual The exhaust system must be unique for each generator, no discharges in the flue shared with other devices are allowed (figure 6). figura 6 In the event that the mouth of the existing flue is not perpendicular to the smoke outlet of the hearth, their connection must be made using the appropriate inclined fitting...
  • Page 14 user manual CHIMNEY Correct installation of the chimney allows to optimize the operation of the stove. The area of ​ ​ t he openings for smoke evacuation must be at least double the section of the flue. It must be positioned in such a way that, even in windy conditions, the exhaust of fumes is ensured.
  • Page 15: Assembly

    user manual 3. ASSEMBLY 3.1 GENERAL WARNINGS In order to avoid all accidents or damage to the product, we The unpacking and installation operations must be carried out by at least two person • recommend: • Unpack the product taking care not to damage or scratch it, remove all accessories and other removable parts •...
  • Page 16: Deflectors

    3.4 DEFLECTORS In the Lia model there are 2 trapezoidal-shaped deflectors. (figure 13), these must be positioned on the fins placed in the upper part of the combustion chamber (side fins). (figure 14). (figura14) (figura13)
  • Page 17 Ermetic Stove An ermetic stove is a product that allows you to take the air necessary for combustion and its operation directly from the outside, therefore without the provision of an air intake inside the room. This translates into a substantial reduction in thermal changes and the energy needs of your home, improving your comfort and saving in terms of fuel and operating costs.
  • Page 18: Use Of Stove

    user manual 4. USE OF THE STOVE 4.1 LCD CONTROL PANEL The display shows information on the operating status of the stove. tasto 1 tasto 3 tasto 4 tasto 5 tasto 2 tasto 6 temperature increase / decrease setting menù access start and stop power increase / decrease setting COMPLETE INSTRUCTIONS ON USING THE DISPLAY IN THE FOLLOWING PAGES...
  • Page 19: First Start Operations

    USER MANUAL 4.3 FIRST START OPERATIONS Before starting the stove, it is necessary to have the “FIRST START UP” and calibration carried out by a specialized technician. Make sure that the electrical connections have been performed. Before lighting the stove, also check that the burner is positioned correctly and that it is the right one for the type of fuel chosen.
  • Page 20 USER MANUAL START After the preparation phase, the message “LOAD ” appears on the display and the ignition phase begins. This second phase is divided into two parts: the preload and the actual ignition. At the beginning, the auger is activated and the fuel begins to fall into the brazier .. As soon as the fuel covers the spark plug hole, you will first notice a redness in the burner and then the ignition of the flame (FIRE PRESENT), the pellet supply is reduced and the ventilation increased in a way.
  • Page 21 USER MANUAL If the room temperature reaches the set temperature, the stove goes to the minimum power level and the word "MODULA" appears in the last line of the display. This modulation state ends only if the room temperature returns to being lower than the set temperature.
  • Page 22 USER MANUAL IGNITION FAILURE ALARM If the ignition of combustion is not detected, the display will show "AL 5 NO IGNITION". To deactivate the alarm state, press the SET button (4) for a long time (approx. 2 seconds). The alarm stops and the stove first returns to the "FINAL CLEANING" state and then to "OFF".
  • Page 23: Display

    user manual Motherboard connection The connection of external thermostat must be done by a free contact (only on/off)
  • Page 24 user manual...
  • Page 25: Console

    user manual...
  • Page 26: User Menu

    user manual...
  • Page 27 user manual...
  • Page 28 user manual Pellet / nocciolino 11-Set Flame +5...-5 -Pellet +5...-5 -Chimney...
  • Page 29 user manual...
  • Page 30 user manual Thecnical...
  • Page 31 user manual Avaiabl only by assistance- Key Access Menu - Set Flame ( sub menu Pellet / Chimney) By accessing in pellet type and chimney type, it allows the% variation of fuel drop and suction. The variation is 5% for each point. To be used carefully under the supervision of a technician Ex.
  • Page 32 user manual...
  • Page 33 user manual When the temperature of the fumes is adequate, the stove goes into operation and subsequently the room fan will start. Otherwise the stove will go into error.
  • Page 34 user manual When the room temperature reaches the set temperature, the emitted color power is automatically brought to a minimum If the stand - by mode is activated, the stove switches off after about 5 minutes after reaching the set temperature. The stove will restart when the stove temperature has dropped by about one degree (internal tolerance) ex.
  • Page 35 user manual The extractor will continue to operate until the stove has cooled down technical...
  • Page 36 user manual...
  • Page 37: Alarms

    user manual Black Out a timing...
  • Page 38 user manual...
  • Page 39 user manual...
  • Page 40: Maintenance

    user manual 6. MAINTENANCE 6.1 ORDINARY MAINTENANCE All maintenance operations must be carried out with the fire out and when the stove is cold. Furthermore, never use abrasive substances. ATTENTION: FAILURE TO CLEAN YOUR STOVE SAFETY AND OPERATION. 1. Clean the brazier simply by lifting it from its seat; and empty it of ashes and any incrustations that could form paying particular attention to free the clogged holes.
  • Page 41 MANUALE UTENTE USO E MANUTENZIONE In the Lia model, remove the side cap (figure 18a) and unscrew the underlying cap fixed with 4 bolts (figure 18 b), the side on which to intervene corresponds to that of the smoke outlet. (For easier work it is also possible to remove the top cover and...
  • Page 42 user manual In the presence of adverse weather conditions, rain or cold temperatures, it is strongly recommended to clean the flue, paying particular attention to the inspection “T” present, in order to avoid bad combustion due to any deposits of water or debris.
  • Page 43: Anomalies

    user manual 7. ANOMALIES All repairs must be carried out by a specialized technician. Make sure before any intervention that the stove is switched off and disconnected from the electricity mains. ANOMALY CAUSE REMEDIES The pellet tank is empty Fill the tank gearmotor faulty Replace the gearmotor electronic ingboard...
  • Page 44 user manual ANOMALY REMEDIES CAUSE Ignition phase not completed Restore the ignition phase electric blackout restart blocked chimney Clean the smoke duct Sudden shutdown after a few minutes from start Poor fuel Change the type of fuel Fill the pellet tank if empty and lack of pellet check the motor-driven screw conveyor and the pellet feed...
  • Page 45: Parameters Tab

    USER MANUAL ANOMALY CAUSE REMEDIES control or replace fan Faulty fan. room probe is faulty control or replace probe Failure to stop the air fan. The product has not yet reached Attendere. the shutdown temperature. faulty electronic board Replace electronic board Remote control battery low replace battery The remote control...
  • Page 46 PR61 PR28 PR61 PR29 PR62 PR29 PR62 PR30 PR63 PR30 PR63 PR31 PR64 PR31 PR64 PR32 PR65 PR32 PR65 PR33 PR66 PR33 PR66 IT IS ABSOLUTELY FORBIDDEN TO CHANGE THE REPORTED VALUES WITHOUT THE AID OF PASIAN AUTHORIZED TECHNICAL ASSISTANCE...
  • Page 47 CONDIZIONI DI GARANZIA 1. Pasian garantisce all’acquirente per 24 mesi le parti strutturali in acciaio e quelle non soggette ad usura a con- dizione che l’acquirente compili e conservi la fattura come prova di acquisto. Tale garanzia è valida a patto che l’acquirente: a) abbia installato l’apparecchio nel rispetto delle norme vigenti;...
  • Page 48 MANUALE UTENTE USO E MANUTENZIONE CEDOLINO DI GARANZIA (da compilare e conservare) Modello e potenza (termo)stufa___________________________________________ Numero di matricola____________________________________________________ Data di acquisto_______________________________________________________ Timbro e firma del rivenditore Il tecnico abilitato garantisce che l’installazione è stata effettuata a regola d’arte e che sono stati rispettati tutti regolamenti locali, inclusi quelli che fanno riferimento alle norme nazionali ed europee.Il CAT, dopo aver constatato che l’installazione è...
  • Page 49 MANUALE UTENTE USO E MANUTENZIONE CERTIFICAZIONE AMBIENTALE: 4 STELLE...
  • Page 50 MANUALE UTENTE USO E MANUTENZIONE PASIAN SRL OGLIANO CAVOUR (LE) Tel & Whatsapp: 0836 543750 - Fax: 0836 544431 www.pasianpellets.it - info@pasianpellets.it - info@pasian.eu...