Door-Gard 2000e Installation & Programming

Door-Gard 2000e Installation & Programming

Advertisement

2000e & 2000eM Keypad Installation & Programming
Specifi cations
Parameter
Voltage Requirements
Keypad Current
Requirements (Max)
Keypad with Output
Expansion Module
(2000-8EX) Current
Requirements (Max)
Relay Contact Rating
REX Input
Door Position Switch Input
Mechanical Dimensions
Environment
Temperature Tolerance
Front End Cable Type
Front End Distance and
Wire Gauge
Firmware Version
Technical Support
DEALERS/INSTALLERS ONLY! End users must contact the
dealer/installer for support. If the keypad still does not work after
troubleshooting, please call the Technical Services department
at 1-800-421-1587.
6-104402 X2
Specifi cations
10-30 VDC; 12-24 VAC
VDC
VAC
10V: 85mA
12V: 150mA
30V: 115mA
24V: 200mA
VDC
VAC
10V: 230mA
12V: 500mA
30V: 390mA
24V: 700mA
Note: This is total maximum
current including keypad and
output module.
2A @ 30VDC (Main & Aux)
Normally Open Dry Contact
Normally Closed Dry Contact
4.50" H x 2.75" W x 0.60" D
Indoor or Outdoor
-31°F to 151°F (-35ºC to 66°C)
Stranded and Shielded
1000 Ft. – 18 AWG
500 Ft – 20 AWG
250 Ft. – 22 AWG
1.0x ("1" is the major version;
"0" is the minor version; "x" is
a minor version, reserved for
bug fi xes, which is indicated
with a letter, such as "a".)
Installation & Programming Instructions
Note: This product is designed to be installed and serviced
Keypad Operating Modes
The 2000e/2000eM keypad has three operating modes: Standalone
Mode, Secured Series Front End Mode and Wiegand Front End
Mode. Below is a brief explanation of each mode. Refer to the
programming section for details about selecting each mode.
Standalone Mode:
By default, the keypad is programmed for Standalone Mode. In this
mode, all the users and other programming options are maintained
within the keypad and no additional controller is required. The
lock and all other inputs and outputs are connected directly to the
keypad.
Secured Series Front End Mode:
In Secured Series Front End mode, a Secured Series Controller is
required. The Secured Series Controller maintains the users and
programming options and makes all the access control decisions.
The locking device and all inputs and outputs are connected to
the controller. The 2000e/eM keypads were evaluated by UL, in
Secured Series Front End mode, for use only with the Hub Max II
and Hub MiniMax II products.
Wiegand Front End Mode:
In Wiegand Front End mode, a separate Wiegand Access Control
panel is required. When you enter a code on the keypad it is then
sent to the control panel as Wiegand card data, depending on
which format you've programmed it for. The control panel maintains
the users and programming options and makes all the access
control decisions. The locking device and all inputs and outputs
are connected to the control panel. The 2000e/eM keypads were
evaluated by UL, in Wiegand Front End mode, for use only with the
Hub Max II and Hub MiniMax II products used in conjunction with
the Wiegand Interface Module.
Mounting the Keypad
The keypad is designed to be fl ush mounted using a standard UL
Listed single-gang electrical box. Mounting height can vary depending
on requirements. An appropriate range is typically between 48 and 52
inches on center off the fl oor.
For outdoor installations, use a UL Listed weatherproof back box and
seal the wire entry locations with silicone and provide a drain hole.
For additional protection, install the provided foam gasket between
the keypad and the back box. In addition, use the anti-oxidant grease
pack for the wire harness connectors.
2000e & 2000eM Keypad
by security and lock industry professionals.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2000e and is the answer not in the manual?

Questions and answers

Summary of Contents for Door-Gard 2000e

  • Page 1 The locking device and all inputs and outputs are connected to Relay Contact Rating 2A @ 30VDC (Main & Aux) the controller. The 2000e/eM keypads were evaluated by UL, in REX Input Normally Open Dry Contact Secured Series Front End mode, for use only with the Hub Max II and Hub MiniMax II products.
  • Page 2: Circuit Board Diagram

    2000e & 2000eM Keypad Installation & Programming Circuit Board Diagram UL Requirements Note: J3 is for use The 2000e/2000eM keypad is a UL Listed access control unit. This only with the 2000-8EX section contains information regarding the requirements necessary to Output Module.
  • Page 3 2000e & 2000eM Keypad Installation & Programming Wiring a Maglock (Fail-Safe) Wiring the REX and Door Position Switch Connect the red wire (V+) to the blue wire (common), and Connect the brown wire (REX Input) to the normally open then connect them to the positive on the power supply.
  • Page 4: Programming Users

    2000e & 2000eM Keypad Installation & Programming Changing the Master Code Programming Users The fi rst step in setting up your keypad is to enter program mode and (Standalone Mode Only) change the master code. The default master code is 1234.
  • Page 5: Assigning Outputs

    2000e & 2000eM Keypad Installation & Programming Assigning Virtual Outputs to Physical Outputs Programming Output Times (Standalone Mode Only) (Standalone Mode Only) The keypad is equipped with nineteen Virtual Outputs and twelve Command/Action Keys to Enter/Details Physical Outputs. Virtual Outputs are functions that you can assign to Change Lock Output Time 11 # time # 0 # ✱...
  • Page 6: Resetting The Keypad

    After entering the command to program a card user, enter the code 0 – Wiegand Site ID Refer to Wiegand Format Chart on the 2000e/eM keypad to send the data to the controller. 1 – Wiegand Group ID Refer to Wiegand Format Chart Please refer to the Wiegand Interface Module instructions 6-065700, Note: The default setting for both settings is 0.
  • Page 7: Limited Warranty

    2000e & 2000eM Keypad Installation & Programming Wiring the 2000-8EX Output Module Performing the Keypad Self-Test If the Output Module is within 18 inches of the keypad, use the After installing the keypad, it is recommended that you perform the...

This manual is also suitable for:

2000em

Table of Contents

Save PDF