Summary of Contents for CF MOTO CF500

  • Page 81 1 . Bolt M8X55 21. Steering arm 11 . Bolt M8X22 2 . Alum cover 12 . Steering bearing seat 22 . Bolt M8X35 13. Bearing 3.O-ing; 23 . Washer 8 14 . Steering shaft support 4. Steering shaft coat 24 .
  • Page 82 Steering column 1.Removal 2.Remove upper cover of handlebar 3.Remove plastics 4.Remove front wheel 5.Remove handlebar 6.Remove handlebar brake lever 7.Remove connector of handlebar switches 8.Remove nut of steering tie-rod and steering column 9.Remove 4 bolt 15 10.Use slotted screw driver and hammer to fix 11.Lock clip 1 flap 12.Remove bolt 13.Remove bolt...
  • Page 83 EPS steering system The EPS indicator light works when the vehicle is equipped with EPS system . Under normal conditions EPS indicator light is on after turning power switch on. EPS doesn't work; EPS indicator light is off after engine is started EPS begins to work. NOTE: Spare parts in the EPS system cannot be taken apart by user.
  • Page 84 1 BOLT M8×55 20 BOLT,M8×25 2 RUBBER COLLAR,FRONT LICENSE PLATE BRACKET 21 BOLT,M10×20 3 BRACKET (RH), DASHBOARD 22 COTTER PIN,2.0×16 4 BRACKET (LH), DASHBOARD 23 HEXAGON SLOTTED NUTS, STYLE1 M10×1.25 5 ALUM. COVER, HANDLEBAR 24 WASHER 10 6 BOLT, M6×125 25 STEERING ARM 7 FRONT BRACKET, DASHBOARD 27 STEERING TIE-ROD...
  • Page 85 Installation Reverse the removal procedure for installation note:after installation be sure to check steering agility; cable instal- lation according to chapter 1, be sure steering arm in the middle be patient when install steering shaft then lock other parts. EPS motor remove 1.Remove plastics 2.Remove front wheel 3.Remove handlebar...
  • Page 86 EPS system fault code table EPS indicator light on the instrument flashes when fault occurs. At that time, do not cut the power off but observe the frequency of flashing and record the orderliness in a period. Then please check with this table to find troubleshooting.
  • Page 87 fault analysis & emergency countermeasure for EPS System Failure Probable Reason Troubleshooting Phenomenon 1.connectors of wire is bad contact 1.Check whether wire connectors are Steering 2.The fuse blew out fully inserted without 3.Relay damage 2.Replace the fuse( 30A) assistance 4.Thecontroller motor or sensor is 3.Replace the relay damaged 4.Contact with suppliers and replace it...