Advertisement

RuiDa Technology Co., Ltd
Addr: 202-203,B-Block,Technology Building,NO.,1057 Nanhai
Avenue,Nanshan
Province,P.R.China
Tel:
0755--26066687
Fax:
0755--26982287
E-mail:
sales@rd-acs.com
Web:
www.rd-acs.com
SHENZHEN RUIDA TECHNOLOGY
User's Manual of RDC6442G(U)-DFM-RD Control System
Read this manual before operation
The content include of electric connections and operating steps
Read the manual to operate the systems
RDC6442G(U)
District,Shenzhen
city,Guangdong
-DFM-RD
Control System Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RDC6442G-DFM-RD and is the answer not in the manual?

Questions and answers

Summary of Contents for RuiDa RDC6442G-DFM-RD

  • Page 1 Read this manual before operation The content include of electric connections and operating steps  Read the manual to operate the systems  RDC6442G(U) -DFM-RD Control System Manual RuiDa Technology Co., Ltd Addr: 202-203,B-Block,Technology Building,NO.,1057 Nanhai Avenue,Nanshan District,Shenzhen city,Guangdong Province,P.R.China Tel: 0755--26066687...
  • Page 2 User’s Manual of RDC6442G(U)-DFM-RD Control System COPYRIGHT All rights reserved.You may not reproduce, transmit, store in a retrieval system or adapt thispublication, in any form or by any means, without the prior written permissionof RuiDa, except as allowed under applicable copyright laws.
  • Page 3 This product has been certified by EU legislation (Restriction of Hazardous Substances) Safety certification; comply with relevant EU environmental regulations. This product has been certified by the Federal Communications Commission for safety, Comply with us electronic safety regulations. SHENZHEN RUIDA TECHNOLOGY...
  • Page 4 This sign indicates laser radiation, which is usually posted on products with laser output. Please be careful with laser and pay attention to safety when using this kind of equipment. SHENZHEN RUIDA TECHNOLOGY...
  • Page 5 After receiving the product, please check whether the outer package is intact, check whether the product is complete after unpacking and whether all parts are intact. If any damage is found, please contact ruida immediately. Remove all cargo from package and keep packing material and wiring parts. Please take care of the safety of the goods when unpacking them.After taking out the goods, please...
  • Page 6: Table Of Contents

    Section 8 Operating Instruction of Panel....................26 8.1 Introduction to the Panel and Keys....................27 8.1.1 The whole panel........................28 8.1.2 Introduction to the Keys......................29 8.2 Introduction to the Main Interface....................30 8.2.1 The whole panel........................28 8.2.2 Introduction to the Keys......................29 SHENZHEN RUIDA TECHNOLOGY...
  • Page 7 8.3.11 IP Setup........................... 28 8.3.12 Diagnoses..........................29 8.3.13 Screen Origin...........................29 8.4 File Key............................. 31 8.4.1 Memory File..........................28 8.4.2 U Disk File..........................29 8.5 Introduction to some alarm info......................32 Section 9 Manufacturer/User Parameters Explanation................26 9.1 Manufacturer parameters........................27 9.2 User parameters..........................53 SHENZHEN RUIDA TECHNOLOGY...
  • Page 8: Section 1 Overview

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section 1 Overview CONTENTS: Briefing Description of Controller Model Comparison of Controller Performance SHENZHEN RUIDA TECHNOLOGY...
  • Page 9 Feature and non-interacted analog independently independently non-interacted non-interacted Copying Common Quick Quick Very Quick Speed Feature Compatib Support Support all USB Support all USB Support ility USB disks with disks with different disks with different SHENZHEN RUIDA TECHNOLOGY...
  • Page 10 YES (the work time Preview time accurate time accurate accurate to 1ms) 1ms) 1ms) Online Update Mainboard Program Online Modification Displa Laser Power/Speed Featur Offline Modification Layer parameters Online Update Startup Display File dynamic/static preview progress display Modificati Factory/User’s SHENZHEN RUIDA TECHNOLOGY...
  • Page 11 PC time integrated integrated Feature hardware encryption hardware encryption Comm USB2.0 10/100MHZ 10/100MHZ 10/100MHZ unicate Ethernet or USB2.0 Ethernet or USB2.0 Ethernet USB2.0, Mode communication mode is automatically checked SHENZHEN RUIDA TECHNOLOGY...
  • Page 12: Section 2 Installation Size

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section 2 Installation Size CONTENTS: Installation Size of MainBoard Size of Panel SHENZHEN RUIDA TECHNOLOGY...
  • Page 13: Installation Size Of Mainboard

    User’s Manual of RDC6442G(U)-DFM-RD Control System 2.1 Installation Size of MainBoard The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm (the four holes are symmetrical) Figure SHENZHEN RUIDA TECHNOLOGY...
  • Page 14: Size Of Panel

    User’s Manual of RDC6442G(U)-DFM-RD Control System 2.2 Size of Panel The unit of all sizes is millimeter (mm) and the size accurate to 0.1mm. Figure SHENZHEN RUIDA TECHNOLOGY...
  • Page 15: Section3 Object Pictures And Interfaces

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section3 Object Pictures and Interfaces CONTENTS: Object Pictures of MainBoard Object Pictures of Panel Electric connection Lamp instruction SHENZHEN RUIDA TECHNOLOGY...
  • Page 16: Object Pictures Of Mainboard

    User’s Manual of RDC6442G(U)-DFM-RD Control System 3.1 Object Pictures of MainBoard For more detailed pin description, see the Chapter 4: Description of Interface Signal for MainBoard. Figure: 3.1-1 Object Picture MainBoard SHENZHEN RUIDA TECHNOLOGY...
  • Page 17: Object Pictures Of Panel

    User’s Manual of RDC6442G(U)-DFM-RD Control System 3.2 Object Pictures of Panel Figure: 3.2-1 Object Picture of Panel SHENZHEN RUIDA TECHNOLOGY...
  • Page 18: Electric Connection

    RDC6442G have fifteen red lamps: LED NUMBER NAME SENSE LED1 LmtX- negative limit indicator LED2 LmtX+ positive limit LED3 LmtY- negative limit LED4 LmtY+ positive limit LED5 LmtZ- negative limit LED6 LmtZ+ positive limit LED7 LmtU- negative limit SHENZHEN RUIDA TECHNOLOGY...
  • Page 19 User’s Manual of RDC6442G(U)-DFM-RD Control System LED8 LmtU+ positive limit LED9 Indication water protect 1 LED10 Indication water protect 2 LED11 Ethernet communication LED12 Link Ethernet connection LED13 error controller hardware LED14 the normal running status LED15 +5V power supply SHENZHEN RUIDA TECHNOLOGY...
  • Page 20: Section 4 Description Of Interface Signal For Mainboard

    Interface of Main Power Source CN0 Panel Signal-Cable Interface HMI Udisk Interface PC-USB Interface Ethernet Interface General Output Port CN1 General Input Port CN2 4-axle Spacing Input Interface CN3/CN4 X/Y/Z/U axle Motor Driver Interface AXIS_X~AXIS_U Laser Power Control Interface CN5/CN6 SHENZHEN RUIDA TECHNOLOGY...
  • Page 21: Interface Of Main Power Source Cn0

    PC-USB is a USB-BM interface. The controller may communicate with PC by this port. 4.5 Ethernet Interface Using this interface, the mainboard can communicate with PC by 10/100MHZ Ethernet. Pin to Pin Ethernet parallel line is recommended. Caution SHENZHEN RUIDA TECHNOLOGY...
  • Page 22: General Output Port Cn1

    “Start/Pause” key. If the interval time to the first stepping-down of the pedal should be less than 100ms when the pedal is stepped down once again, the SHENZHEN RUIDA TECHNOLOGY...
  • Page 23: 4-Axle Spacing Input Interface Cn3/Cn4

    The pin definitions of Z/U axle spacing input CN3 are the same as CN4. All XYZU axle spacing inputs are compatible to 5V/12V/24V logic level inputs 。 SHENZHEN RUIDA TECHNOLOGY...
  • Page 24: X/Y/Z/U Axle Motor Driver Interface Axis_X~Axis_U

    1. When the laser is the RF laser, this pin will be connected with the laser RF-PWM end; 2. When the laser is a glass tube, this pin will be connected with the laser power PWM end and used to control the power of the laser. SHENZHEN RUIDA TECHNOLOGY...
  • Page 25 Water protection input must be 24V logic level. L-AN1 The analog signals for Laser Power. If Glass Tube is used, this pin is recommended to control the power of the Laser. Please correctly select the laser type in the factory parameters. Prompt SHENZHEN RUIDA TECHNOLOGY...
  • Page 26: Section 5 Examples Of Laser Power Interface

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section 5 Examples of Laser Power Interface CONTENTS: Brief Examples of Glass tube Laser Power Examples of RF-Laser SHENZHEN RUIDA TECHNOLOGY...
  • Page 27: Brief

    This control system has two independent and adjustable digital laser power control interfaces, which can be used to control glass tube laser power and RF-laser. Please correctly select the laser type in the factory parameters, or, the laser control is incorrect. SHENZHEN RUIDA TECHNOLOGY...
  • Page 28: Examples Of Glass Tube Laser Power

    User’s Manual of RDC6442G(U)-DFM-RD Control System 5.2 Examples of Glass tube Laser Power SHENZHEN RUIDA TECHNOLOGY...
  • Page 29: Examples Of Rf-Laser

    User’s Manual of RDC6442G(U)-DFM-RD Control System 5.3 Examples of RF-Laser SHENZHEN RUIDA TECHNOLOGY...
  • Page 30 User’s Manual of RDC6442G(U)-DFM-RD Control System Section 6 Examples of Driver Interface for Step-servo Motor CONTENTS: Brief Examples of Motor Driver Connection SHENZHEN RUIDA TECHNOLOGY...
  • Page 31: Brief

    Figure: 6.1-1 Four Inputs, Independent Figure: 6.1-2 Three Inputs, Common-anode Input Signal of Driver Input Signal of Driver SHENZHEN RUIDA TECHNOLOGY...
  • Page 32: Examples Of Motor Driver Connection

    User’s Manual of RDC6442G(U)-DFM-RD Control System 6.2 Examples of Motor Driver Connection SHENZHEN RUIDA TECHNOLOGY...
  • Page 33: Section 7 Examples Of Io-Port Wiring

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section 7 Examples of IO-port Wiring CONTENTS: Input Output SHENZHEN RUIDA TECHNOLOGY...
  • Page 34: Input

    User’s Manual of RDC6442G(U)-DFM-RD Control System Input The two water protection inputs are 24V logic level; all other inputs are compatible with 5V/12V/24V logic level. Input connection shown as below Figure 7.1-1 example of input SHENZHEN RUIDA TECHNOLOGY...
  • Page 35: Output

    7.2 Output All outputs are isolated through the optocoupler, and 500mA current for each, OC gate output, each can directly drive the 6V/24V relay, led lamp, buzzer etc. Output connection shown as below Figure 7.2-1 example of output SHENZHEN RUIDA TECHNOLOGY...
  • Page 36: Section 8 Operating Instruction Of Panel

    User’s Manual of RDC6442G(U)-DFM-RD Control System Section 8 Operating Instruction of Panel CONTENTS: Introduction to the Panel and Keys Introduction to the Main Interface Z/U Key File Key Introduction to some alarm info SHENZHEN RUIDA TECHNOLOGY...
  • Page 37: Introduction To The Panel And Keys

    :The management of the memory and U disc files; :Set the speed of the current running layer, or set the direction keys’ move Speed speed; Max. :Set the max laser power of the current running layer, or set the power of Power “Laser” Key; SHENZHEN RUIDA TECHNOLOGY...
  • Page 38: Introduction To The Main Interface

    :To stop work, or to exit to some menu; : Validate the change; Enter  8.2 Introduction to the Main Interface 8.2.1 The main interface When the system is powered on, the screen will show as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 39 But, when work is running or paused, some keys don’t respond when they are pushed. 8.2.2 Speed key Push the “Speed” key when the screen is on the main interface, it will show as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 40: Max/Min Power Keys

    Figure 8.2-3 Figure 8.2-4 When “Z/U” key is pushed, the green block can move up and down to denote the changing item, then “Y+/-” keys and “X+/-” keys can be used to change the value. SHENZHEN RUIDA TECHNOLOGY...
  • Page 41: Set The Layer Parameters

    “OK” to validate the change, and “Esc” to invalidate the change. Z/U Key The Z/U key can be pressed when the system is idle or the work is finished. On pressing this key, it will show some entries in the following interface: SHENZHEN RUIDA TECHNOLOGY...
  • Page 42: Z Move

    When the green block is on “U Move” item, “X+/-” keys can be used to move the u axes. 8.3.3 Axis reset+ When the green block is on this item, push the “Enter” key to show as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 43: Manual Set

    When the Mode item is “manual”, then pushing the direction key one time, the corresponding axes will move a fixed length, unless the scope is overstepped. SHENZHEN RUIDA TECHNOLOGY...
  • Page 44: Laser Set

    Mode item is “manual”, then pushing the Laser key one time, the enabled lasers will splash a fixed time. 8.3.6 Origin set+ When the green block is on this item, push the “Enter” key to show as below: Figure 8.3-5 SHENZHEN RUIDA TECHNOLOGY...
  • Page 45: Set Fact Para

    The rotation order of origin is 1->2->3->4->1->2……. 8.3.7 Set Fact Para After the “Set Fact Para” is selected and the Enter key pressed, the interface will show the specific password to be entered when set as default parameter. SHENZHEN RUIDA TECHNOLOGY...
  • Page 46: Def Fact Para

    Esc key to return the prior menu. 8.3.10 Language The item “Language” helps you to select a appropriate langue which is displayed on the pane: SHENZHEN RUIDA TECHNOLOGY...
  • Page 47: Ip Setup

    IP value and the Gateway value are changed, push “Enter” key to validate the change, or “Esc” key to invalidate the change. 8.3.12 Diagnoses If the “Diagnoses” item is pressed, the system will show as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 48: Screen Origin

    Figure 8.3-10 There are four entries to be selected: Top Left, Top Right, Bottom Left and Bottom Right. When one is selected, the previewed graph on the screen would be enantiomorphous based on X or Y direction. SHENZHEN RUIDA TECHNOLOGY...
  • Page 49: File Key

     Work time: To forecast the running time of the selected file, and the time is accurate to 1ms;  Clear count: To clear the running times of the selected file;  Delete: To delete the selected file in the memory; SHENZHEN RUIDA TECHNOLOGY...
  • Page 50: U Disk File

     Total: the total running times of all the files. 8.4.2 U Disk File If the “Udisk” entry in figure 8.4-1 is pressed, the system will show as figure 8.4-3, and the operation method is all the same as figure 8.4-1. SHENZHEN RUIDA TECHNOLOGY...
  • Page 51: Introduction To Some Alarm Info

    The files copied from the mainboard to Udisk will be placed under the root directory of Udisk. Introduction to some alarm info When users are operating the system, or when the machine is running, some alarm information such as water protecting error maybe shows as below: SHENZHEN RUIDA TECHNOLOGY...
  • Page 52 User’s Manual of RDC6442G(U)-DFM-RD Control System Figure 8.5-1 Push “Enter” key or “Esc” key, the system will execute some relative steps. SHENZHEN RUIDA TECHNOLOGY...
  • Page 53 User’s Manual of RDC6442G(U)-DFM-RD Control System Section 9 Manufacturer/User Parameters Explanation CONTENTS: Manufacturer parameters User parameters SHENZHEN RUIDA TECHNOLOGY...
  • Page 54: Manufacturer Parameters

    For example, the typical value is 200~500mm/s.  Maximum Acceleration: it means the maximum acceleration of the motion axle in accelerated or decelerated motion. If the acceleration is set too large, it will make the SHENZHEN RUIDA TECHNOLOGY...
  • Page 55 Laser PWM Frequency is used to set the pulse frequency of control signal used by this laser, in general, glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum SHENZHEN RUIDA TECHNOLOGY...
  • Page 56 Whether to enable the blower: If using wind out port to control the blower by  the graph layer parameter, this item must be enabled, or, the wind output is a signal for other using. SHENZHEN RUIDA TECHNOLOGY...
  • Page 57: User Parameters

     Scanning Mode: it is divided into general mode and special mode for option. If special mode is used, the laser power should be increased. The smaller the speckle SHENZHEN RUIDA TECHNOLOGY...
  • Page 58 The size and position of this figure can be checked intuitively through the four points. The bordering speed is the speed value set on the keyboard when the system is idle. For light output, its minimum/maximum power is the corresponding value SHENZHEN RUIDA TECHNOLOGY...
  • Page 59  Focus Setting: it means the distance from the focal point of laser head lens to Z-axle origin. When there is no automatic focusing function, this parameter becomes invalid.  Backlash X: The X axes’ backlash, accurate to 1um.  Backlash Y: The Y axes’ backlash, accurate to 1um. SHENZHEN RUIDA TECHNOLOGY...
  • Page 60 User’s Manual of RDC6442G(U)-DFM-RD Control System Thank you for your selection of our production! All the copyright of this manual is owned by Ruida technology. Any person or company can not copy upload and send the manual without Ruida’s permission.

This manual is also suitable for:

Rdc6442u-dfm-rd

Table of Contents