5.5.
ALTERING CORRECTION FACTOR INDIRECTLY
5.5.1.
Wait for meter to go to standby (fig.10).
5.5.2.
Reset the total (5.2.4) fig.11 to zero.
5.5.3.
Dispense into measuring container (minimum 5 litres) and record.
5.5.4.
If displayed value does not match actual measured value
press and hold MOVE key until each digit reads as per the
measured value. Press MOVE key to visit each digit in turn.
5.5.5.
Once value is correct (i.e. matches measured value) press and
hold MOVE key until Cal mode quits (fig.11).
6. MAINTENANCE
6.1.
CHANGING THE BATTERY
6.2.
Battery type: Lithium CR2 3V 1400mAh.
6.2.1.
Remove the rubber protective cover from the meter.
6.2.2.
Remove the screw and cover from the side of the meter.
6.2.3.
Remove and replace battery (fig.14).
6.2.4.
Replace cover and secure with screw.
6.2.5.
Replace the protective rubber cover.
6.3.
Check the unit connections before each use.
Check the nozzle valve for leaks, if it does not seal, replace before using.
6.4.
6.4.
Drain air regulator water trap daily.
6.5.
Top up lubricator as required, using a quality air tool oil.
To change the silencer, remove the circlip (fig.15) and remove the old silencer, place a new silencer into the recess and refit the circlip.
6.6.
NOTE: For any other maintenance and repairs the unit should be returned to your Sealey dealer.
fig.15
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL SEE SECTION 6
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
fig.12
fig.14
www.sealey.co.uk
AK4562D Issue 3 (H, 5, F) 24/09/18
fig.13

Advertisement

loading