  • Page 1 LVO Manufacturing, Inc. PT10 Pan-Washer Owner’s Manual...
  • Page 2: Warranty

    This warranty is in lieu of any other warranties, expressed or implied, made on the part of LVO Manufacturing Inc. who does not accept responsibility to any purchaser of its products for any representation or warranty made by dealers or salespersons beyond those herein expressed including any implied warranties of merchantability or fitness for a particular purpose.
  • Page 3: Table Of Contents

    1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Table of Contents Warranty ..............................2 Table of Contents ............................. 3 PT10 Specifications ..........................4 Electrical Data ............................5 Warnings & Cautions ..........................6 Introduction .............................. 7 Installation Instructions ..........................8 Startup Procedures ..........................11 Sequence of Operation ...........................
  • Page 4: Pt10 Specifications

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ PT10 Specifications Overall Dimensions Width – 37 ½”...
  • Page 5: Electrical Data

    Rinse Heater (one 9 kW) 25.0 22.6 11.3 Total Running Current 70.0 64.4 33.2 Electrical Data for models FL10, PT10, & CL10 – Gas or Injected Steam 208 Volt 230 Volt 460 Volt Pump Motor 18.0 17.2 Control Circuit Rinse Heater (one 9 kW) 25.0...
  • Page 6: Warnings & Cautions

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Warnings & Cautions General Warnings and Cautions: 1. Service work on the machine should be done by either a factory representative or qualified local service company.
  • Page 7: Introduction

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Introduction This manual should be read and understood by everyone involved with the installation and operation of the pan washer.
  • Page 8: Installation Instructions

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Installation Instructions Step 1 READ: Read and understand these instructions thoroughly before attempting any part of the installation process.
  • Page 9 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ machine is located a long distance from the water main, it may be necessary to supply a larger line to the machine to insure proper water pressure and flow for the machine to operate correctly.
  • Page 10 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ shut-off to the machine should be watertight flex conduit. The factory strongly recommends that a few extra feet be used to allow the machine to be moved if necessary.
  • Page 11: Startup Procedures

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Startup Procedures Warning: These instructions must be followed or damage to the machine will result.
  • Page 12 If the machine still does not appear to be heating up properly, call LVO Manufacturing at 1-800-346-5749. Step 9: Set the rinse pressure by changing the pressure adjustment valve located on the top of the machine.
  • Page 13: Sequence Of Operation

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Sequence of Operation  Power switch is switched “ON”...
  • Page 14: Operation Of Machine

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Operation of Machine Initial Daily Startup 1. Check if the inside of the machine has been properly cleaned since its last use. If not, clean the machine (refer to Final Clean-Up on the following page for cleaning information).
  • Page 15 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ CAUTION: When loading the machine make sure that nothing will obstruct the path of the wash arms.
  • Page 16 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Turn the machine off and open the drain valve.
  • Page 17: Preventative Maintenance

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Preventative Maintenance ● Turn off power and drain machine, making sure it drains freely.
  • Page 18: Trouble Shooting - Electric Machines

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Trouble Shooting – Electric Machines Problem Cause Cure Machine won’t run...
  • Page 19: Trouble Shooting - Gas Machines

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Trouble Shooting – Gas Machines (Same as electric model except for the following) Low wash temperature: Check temperature control set point.
  • Page 20: Trouble Shooting Flowchart

    LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Trouble Shooting Flowchart Pan Washer Doesn’t Run Does the power light illuminate when the See Next Page power switch is turned to the “on”...
  • Page 21 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Does the wash light Is the door illuminate when the start...
  • Page 22: Parts List

    Scrap Tray – PT10 105-2011 Button Guard Assembly 105-2006 Rinse Tank – Electric Heat (FL10, PT10) – Threaded Heaters 127-2007 Rinse Tank – Electric Heat (CL10) – Threaded Heaters 105-2045 Rinse Tank – Electric Heat (FL10, PT10) – Clamp Heaters 127-2045 Rinse Tank –...
  • Page 23 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ Heating Parts Part Number Description 509-5004 Wash & Rinse Element, 9 kW 208 Volt – Threaded 509-5005 Wash &...
  • Page 24 Door & Weight Parts Part Number Description 517-5003 Door Handle 103-2048 Door Cable – 8’ (FL10, CL10) 128-2030 Door Cable – 5 ½’ (PT10) 101-2023 Door Cable – 9’ (PT10) 511-5252 Limit Switch 513-5702 ⅛” Cable Clamp 105-6023 2 ½” Cable Pulley...
  • Page 25 LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. LVO Manufacturing, Inc. 808 N. 2 Avenue E., P.O. Box 188 Rock Rapids, IA 51246 www.lvomfg.com (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 __________________________________________________________________________________________________________________________________________________________________ 127-6074 3” Cable Pulley (Single Pulley) 127-6075 3” Cable Pulley (Double Pulley)
  • Page 26: General View

    RINSE CYCLE LIGHT 6" STAINLESS LEG WASH CYCLE LIGHT 1 1/2" DRAIN VALVE Mat. Name: Overview Finish Scale 1:16 Pan Washers PT10 Rev. 10/26/2010 LVO Manufacturing, Inc. 808 N 2nd Ave E Phone: (712) 472-3734 128-1000-7 C. Woiwood Rock Rapids, IA 51246...
  • Page 27: Four View - Electric

    Drain Side View Front View 81 1/4" 1 1/2" Drain Mat. Name: Informative Finish Scale 1:21 Pan Washers PT10 Electric Rev. 10/26/2010 LVO Manufacturing, Inc. 808 N 2nd Ave E Phone: (712) 472-3734 128-1000-1 C. Woiwood Rock Rapids, IA 51246...
  • Page 28: Four View - Gas

    Drain Front View Side View 84 1/4" 1 1/2" Drain Mat. Name: Informative Finish Scale 1:21 Pan Washers PT10 Gas Rev. 10/26/2010 LVO Manufacturing, Inc. 808 N 2nd Ave E Phone: (712) 472-3734 128-1100-1 C. Woiwood Rock Rapids, IA 51246...
  • Page 29: Door Weight & Cable Assembly

    Holes may need to be drilled on old style doors with three holes. Mat. Scale Name: Door & Weight 1:10 LVO Manufacturing, Inc 808 N 2nd Ave E Finish Assembly - PT's 10/27/2010 Rock Rapids, IA 561246 Pan Washers Phone: (712) 472-3734 Rev.
  • Page 30: Bun Pan Rack

    Pans are to be inserted facing each other as shown. If Necessary for extremely soiled pans, place a pan in every other slot. Mat. Scale Name: Bun Pan Rack LVO Manufacturing, Inc 808 N 2nd Ave E Finish Informative 4/21/2010 Rock Rapids, IA 561246...
  • Page 31: Cake Pan Rack

    Insert pans as shown so bottom wash arms spray inside of pans. If necessary for extremely soiled pans, place pans in every other row. Mat. Scale Name: Cake Pan Rack LVO Manufacturing, Inc 808 N 2nd Ave E Finish Informative 4/21/2010 Rock Rapids, IA 561246...
  • Page 32: Holddown Rack

    LOWER POSITION NOTE: THIS HOLDDOWN RACK IS NOT TO BE USED AS A SHELF TO SUPPORT HEAVY ITEMS Mat. Scale Name: Holddown Rack LVO Manufacturing, Inc 808 N 2nd Ave E Finish Informative 03-12-97 Rock Rapids, IA 561246 Pan Washers Phone: (712) 472-3734 Rev.
  • Page 33: Ladder Diagram - Electric

    START HEATER WASH SELECTOR RINSE LOGO SOLENOID FILL Mat. Name: Ladder Diagram Finish Scale Pan Washers FL, PT, CL Electric Rev. 08-21-07 LVO Manufacturing, Inc. 808 N 2nd Ave E 124L1101 Phone: (712) 472-3734 M. Elbers Rock Rapids, IA 51246...
  • Page 34: Ladder Diagram - Gas

    VALVE VALVE TO IGNITOR TO FLAME SENSOR Mat. Name: Ladder Diagram Finish Scale Pan Washers FL, PT, CL - Gas Rev. 08-21-07 LVO Manufacturing, Inc. 808 N 2nd Ave E 124L1107 Phone: (712) 472-3734 M. Elbers Rock Rapids, IA 51246...

Table of Contents