Cognex DataMan 8700 Quick Reference Manual

Cognex DataMan 8700 Quick Reference Manual

Hide thumbs Also See for DataMan 8700:

Advertisement

Quick Links

®
DataMan
8700
Quick Reference Guide
2021 October 15
Revision: 6.2.5.62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DataMan 8700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cognex DataMan 8700

  • Page 1 ® DataMan 8700 Quick Reference Guide 2021 October 15 Revision: 6.2.5.62...
  • Page 2 Precautions To reduce the risk of injury or equipment damage, observe the following precautions when you install the Cognex product: This product is intended for industrial use in automated manufacturing or similar applications. The safety of any system incorporating this product is the responsibility of the assembler of the system.
  • Page 3 Symbols The following symbols indicate safety precautions and supplemental information: WARNING: This symbol indicates a hazard that could cause death, serious personal injury or electrical shock. CAUTION: This symbol indicates a hazard that could result in property damage. Note: This symbol indicates additional information about a subject. Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.
  • Page 4: Product Overview

    Product Overview Number DataMan 8700 DX Reader LED aimer Trigger (press and hold to read) Cable insertion point (in case of corded readers) 360° ring light indicator Lanyard hook OLED display...
  • Page 5 Number DataMan 8700 DX Reader OLED input and configuration buttons Diffused light Polarized light Direct light Charging pins (in case of wireless readers) Battery insertion (in case of wireless readers)
  • Page 6 Number DataMan 8700 DQ Reader LED aimer Trigger (press and hold to read) Cable insertion point 360° ring light indicator Lanyard hook OLED display OLED input and configuration buttons Diffused light...
  • Page 7 OLED Display Layout The OLED display is user interface where you can communicate with the DataMan 8700. Number Screen or Icon Description Main Screen First screen after boot up is complete. The main screen contains information about the name of the reader, the Bluetooth connection and the battery status of the reader.
  • Page 8: Base Station Overview

    Base Station Overview DMB8700-BT Base Station Base station status indicators Connection point with the reader: pairing reader and base station non-wireless communication charging Cable plug...
  • Page 9 DataMan 8700 Accessories Accessory Name Product ID Illustration DM8700-USB- DM8700 slide-in communication conversion kits DM8700-RS- DM8700- ENET-KIT Intelligent Bluetooth DMB8700-BT Power Supply for USB and RS-232 communication on the corded reader or DM8700- wireless base station reader and base station...
  • Page 10 Accessory Name Product ID Illustration PoE injector for one device CPS-AC- POE1A-xx Wall Mount Bracket DMA-WALL- 8700 Presentation Stand, can be used with wall mount bracket (DMA-WALL-8700) DM-STAND- Cables Accessory Name Product ID Illustration RS-232 coiled cable, 2.5 m with Dsub-9 connector, power over pin 9 DMC-HH-RS232P- RS-232 coiled cable, 2.5 m with Dsub-9 connector DMC-HH-RS232-02C...
  • Page 11 USB coiled cable, 2.5m with USB type-C connector DMC-HH-USBC-02C Ethernet coiled cable, 5m with RJ45 connector DMC-HH-ENET-05C Ethernet straight cable, 2.5m with RJ45 connector DMC-HH-ENET-02 Ethernet straight cable, 5m with RJ45 connector DMC-HH-ENET-05 Ethernet straight cable, 30m with RJ45 connector DMC-HH-ENET-30 Ethernet coiled cable, 5 m with M12 X-coded connector DMC-HH-ENETM12-...
  • Page 12 Field of View and Reading Distances for 8700DX DM8700 DX Field of View Values Working Distance Horizontal Values Vertical Values = 40 mm (1.5 in) = 63 mm (2.5 in) = 47 mm (1.8 in) = 140 mm (5.5 in) = 126 mm (5 in) = 95 mm (3.7 in) = 300 mm (11.8 in)
  • Page 13 Note: All values beginning with 0 denote the minimum distance where the Field of View is able to see the entire code. DM8700 DX Depth of Field Values Distances in mm / 1D min code Distances in mm / 2D min code 18-58 3 MIL 10-71...
  • Page 14 Field of View and Reading Distance for 8700DQ DM8700 DQ Field of View Values Working Distance Horizontal Values Vertical Values = 48 mm (1.9 in) = 79 mm (3.1 in) = 60 mm (2.4 in) = 140 mm (5.5 in) = 148 mm (5.8 in) = 111 mm (4.4 in) = 300 mm (11.8 in)
  • Page 15 DM8700 DQ Depth of Field Values Distances in mm / 1D min code Distances in mm / 2D min code 25-70 3 MIL 10-60 5 MIL 55-300 30 MIL...
  • Page 16: Connecting The Reader

    Connecting the Reader Wireless reader Battery Insertion: 1. Pull out metal tab to open the end cap. 2. Insert the battery. 3. Close the end cap by pressing the metal tab. Corded reader Cable insertion: 1. Use a small screwdriver or a pencil to press in the gray tab by the cable insertion.
  • Page 17 2. Turn the cable insertion mechanism to the open position. 3. Insert the cable. 4. Lock the cable by turning the cable insertion mechanism to the opposite direction. Note: Disconnect the DataMan 8700 from power before inserting the communication modules.
  • Page 18: Installation

    DataMan system; do not force the connectors or damage may occur. 1. After installing the software, connect the DataMan 8700 to your PC. 2. Launch the DataMan Setup Tool and click Refresh. 3. Select your DataMan 8700 Series reader from the list and click Connect.
  • Page 19 DataMan 8700 Specifications Specification DataMan 8700 Reader Weight DX Corded: 463g (15.90 oz) + ~132 g (4.60 oz) cables DX Wireless: 548 g (18.70 oz) (battery included) DQ Corded: 395 g (13.90 oz) + ~132 g (4.60 oz) cables Operating Temperature 0 ºC —...
  • Page 20 10/100 Base-T FULL/HALF DUPLEX, IEEE 802.3 Bluetooth Bluetooth 4.2, Classic, 2.4~2.4835 GHz LED Wavelengths for DataMan 8700 Readers Note: The data below refer to the LED Illumination accessory of the reader, not to the LED indicators. The following table shows LED types and the related wavelengths: λ...
  • Page 21: Regulations And Conformity

    Regulations and Conformity The corded DataMan 8700 DX and DQ have Regulatory Models R00083 and R00084, respectively. The wireless DataMan 8700 DX have Regulatory Model R00085, and meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow.
  • Page 22 This Class A digital apparatus complies with Canadian ICES- 003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. TÜV Corded DataMan 8700 DX: Regulatory Model R00083 Corded DataMan 8700 DQ: Regulatory Model R00084 NRTL: TÜV SÜD SCC/NRTL OSHA Scheme for UL/CAN 61010-1.
  • Page 23 The following specifications apply to the DataMan 8700 DX wireless reader: Regulator Specification FCC Part 15B, Class A FCC Part 15C contains FCC ID: TXH-50164 ICES-003 Canada RSS 247 contains IC: 6315A-50164 For Bluetooth European Community EN61010-1 EN ETSI 301 489-1/-17...
  • Page 24 Para maiores informações, consulte o site da ANATEL www.anatel.gov.br. TÜV Wireless DataMan 8700 DX: Regulatory Model R00085 NRTL: TÜV SÜD SCC/NRTL OSHA Scheme for UL/CAN 61010-1. CB report available upon request.TÜV SÜD, IEC/EN 61010-1. Korea...
  • Page 25: For European Community Users

    For European Community Users Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE). This product has required the extraction and use of natural resources for its production.
  • Page 26 However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. Note: For the most current CE declaration and regulatory conformity information, see the Cognex support site: cognex.com/support. Please read these guidelines carefully before using your device. Regulator...
  • Page 27 Brazilian Compliance causar interferência em sistemas devidamente autorizados. Para maiores informações, consulte o site da ANATEL www.anatel.gov.br. DataMan 8700 Base Station Regulatory Model R00087 TÜV NRTL: TÜV SÜD SCC/NRTL OSHA Scheme for UL/CAN 61010-1. CB report available upon request.TÜV SÜD, IEC/EN 61010-1.
  • Page 28 中 国 大 陆 RoHS (Information for China RoHS Compliance) 根 据 中 国 大 陆 《 电 子 信 息 产 品 污 染 控 制 管 理 办 法 》 ( 也 称 为 中 国 大 陆 RoHS), 以...
  • Page 29 Copyright © 2021 Cognex Corporation. All Rights Reserved.

Table of Contents