Wiring and Accessories
Power Supply
Fuse
R
S
T
PD
P
Inverter
RB
N
U
V
W
IM
Motor
Motor Output
Input
kW
HP
Voltage
VT
CT
VT
CT
0.4
1/2
WJ200-004MF AWG12/3.3mm
1-phase
100V
0.75
1
WJ200-007MF AWG10/5.3mm
0.2
0.1
1/4
1/8
WJ200-001SF
0.4
0.2
1/2
1/4
WJ200-002SF
0.55
0.4
3/4
1/2
WJ200-004SF
1-phase
200V
1.1
0.75
1.5
1
WJ200-007SF AWG12 / 3.3mm
2.2
1.5
3
2
WJ200-015SF
3.0
2.2
4
3
WJ200-022SF
0.2
0.1
1/4
1/8
WJ200-001LF
0.4
0.2
1/2
1/4
WJ200-002LF
0.75
0.4
1
1/2
WJ200-004LF
1.1
0.75
1.5
1
WJ200-007LF
2.2
1.5
3
2
WJ200-015LF AWG14 / 2.1mm
3-phase
3.0
2.2
4
3
WJ200-022LF AWG12 / 3.3mm
200V
5.5
3.7
7.5
5
WJ200-037LF AWG10 / 5.3mm
7.5
5.5
10
7.5
WJ200-055LF
11
7.5
15
10
WJ200-075LF
15
11
20
15
WJ200-110LF
18.5
15
25
20
WJ200-150LF AWG2 / 34mm
0.75
0.4
1
1/2
WJ200-004HF
1.5
0.75
2
1
WJ200-007HF
2.2
1.5
3
2
WJ200-015HF
3.0
2.2
4
3
WJ200-022HF
4.0
3.0
5
4
WJ200-030HF
3-phase
400V
5.5
4.0
7.5
5
WJ200-040HF AWG12 / 3.3mm
7.5
5.5
10
7.5
WJ200-055HF
11
7.5
15
10
WJ200-075HF
15
11
20
15
18.5
15
25
20
WJ200-150HF
Note 1: Field wiring must be made by a UL-Listed and CSA-certified closed-loop terminal connector sized for the wire gauge involved.
Connector must be fixed by using the crimping tool specified by the connector manufacturer.
Note 2: Be sure to consider the capacity of the circuit breaker to be used.
Note 3: Be sure to use a larger wire gauge if power line length exceeds 66ft. (20 m).
Note 4: Use 18 AWG / 0.75mm
2
wire for the alarm signal wire ([AL0], [AL1], [AL2] terminals).
Name
Input-side AC Reactor
EMC filter
(for CE applications, see Appendix D)
Radio noise filter
Radio noise filter
(use in non-CE applications)
DC link choke
Braking register
Braking unit
Output side nose filter
Radio noise filter
Output-side AC Reactor
LCR filter
Wiring
Inverter
Model
Power Lines
°
(75
C only)
2
(75
°
C only)
2
°
AWG16 / 1.3mm
2
(75
C only)
°
(75
C only)
2
AWG10 / 5.3mm
2
AWG16 / 1.3mm
2
°
(75
C only)
2
°
(75
C only)
2
(75
°
C only)
2
°
AWG6 / 13mm
(75
C only)
2
°
AWG4 / 21mm
(75
C only)
2
°
(75
C only)
2
AWG16 / 1.3mm
2
AWG14 / 2.1mm
2
°
(75
C only)
2
°
AWG10 / 5.3mm
(75
C only)
2
°
WJ200-110HF
AWG6 / 13mm
2
(75
C only)
°
AWG6 / 13mm
(75
C only)
2
Function
This is useful in suppressing harmonics induced on the power supply lines and
for improving the power factor.
WARNING: Some applications must use an input-side AC Reactor to prevent
inverter damage. See Warning on next page.
Reduces the conducted noise on the power supply wiring between the inverter
and the power distribution system. Connect to the inverter primary (input) side.
Electrical noise interference may occur on nearby equipment such as a radio
receiver. This magnetic choke filter helps reduce radiated noise (can also be used
on output).
This capacitive filter reduces radiated noise from the main power wires in the
inverter (input) side.
Suppress harmonics generated by the inverter. However, it will not protect the
input diode bridge rectifier.
This is useful for increasing the inverter's control torque for high duty-cycle (on-
off) applications, and improving the decelerating capability.
Reduces radiated noise from wiring in the inverter output side.
Electrical noise interference may occur on nearby equipment such as a radio
receiver. This magnetic choke filter helps reduce radiated noise (can also be used
on input).
This reactor reduces the vibration in the motor caused by the inverter's switching
waveforms, by smoothing the waveform to approximate commercial power
quality. It is also useful to reduce harmonics when wiring from the inverter to
the motor is more than 10 m in length.
Sine wave shaping filter for output side.
Circuit
Fuse
Breaker
(UL-rated,
Signal Lines
class J, 600V)
(Inverse Time)
50A
30A
10A
30A
20A
30A
10A
30A
15A
18 to 28 AWG /
20A
0.14 to 0.75 mm
2
30A
shielded wire
(see Note 4)
60A
100A
80A
10A
20A
15A
30A
40A
50A
 25