Owner’s Manual Generac PWRcell™ Inverters XVT076A03 XVT114G03 009954 WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: https://pwrfleet.generac.com 1-888-GENERAC...
Page 2
Use this page to record important information about your Generac Product Serial Number Locations Record the information found on your unit data label on this page. See Independent Authorized Service Dealer (IASD) or Generac Customer Service When contacting an , always supply the complete model number and serial number of the unit.
Section 1:Introduction and Safety ....1 Section 4:Maintenance ........19 Introduction ............1 Service ..............19 Read This Manual Thoroughly ........1 Annual Maintenance ......... 19 Safety Rules ............1 Inspecting Vents ............19 How to Obtain Service ..........1 Cleaning Intake Filter ..........19 General Hazards ..........2 Recovery From an Error State ......
Page 4
This page intentionally left blank. Owner’s Manual for Generac PWRcell Inverter...
Introduction and Safety Section 1: Introduction and Safety Introduction Throughout this publication, and on tags and decals Thank you for purchasing a Generac PWRcell™ product. affixed to the unit, DANGER, WARNING, CAUTION, and The PWRcell inverter is a storage-ready inverter that NOTE blocks are used to alert personnel to special connects to PV Link™...
Introduction and Safety • General Hazards Connecting the PWRcell system to the electric util- ity grid must only be done after receiving prior approval from the utility company. DANGER • Only competent, qualified personnel should install, Automatic start-up. Disconnect utility power and operate, and service this equipment.
Page 7
Introduction and Safety Electrical Hazards DANGER DANGER Electrocution. Verify electrical system is Electrocution. Water contact with a power properly grounded before applying power. source, if not avoided, will result in death Failure to do so will result in death or serious or serious injury.
Page 8
Introduction and Safety This page intentionally left blank. Owner’s Manual for Generac PWRCell Inverter...
General Information Section 2: General Information Specifications Description Units XVT076A03 XVT114G03 Max. cont. grid-tied AC power @ 122°F (50°C) 11.4 Max. cont. islanded AC power @ 104°F (40°C) with single 6 module battery cabinet Max. cont. islanded AC power @ 104°F (40°C) 11.0 Range 9.6 to 11.0* with 2 battery cabinets (8 modules minimum)
General Information Serial Number Location Component Locations Refer to Figure 2-2 to locate unit serial number (A). Record the information from this tag in Table 1: PWRcell Inverter Important Information on the inside front cover of this manual. Unit Dimensions 009651 009656 Figure 2-2.
General Information 009893 Figure 2-3. Generac PWRcell System Example A Solar Panels REbus Loads B PV Link PWRcell Inverter Protected Loads C PWRcell Battery Grid Inverter Control Panel REbus Status LED REbus Status LED (C) communicates REbus nanogrid status through LED color. •...
General Information Internet LED Shutdown mode signals all communicating PWRcell equipment on REbus, including the PWRcell inverter, to Internet LED (G) is illuminated when the inverter is disable. Disabled PWRcell equipment will drop their connected to a router and has an IP address. See output voltages to safe levels.
General Information Clean Backup Priority Backup In Priority Backup mode, the inverter prioritizes keeping NOTE: Grid power is not used to charge batteries in this batteries charged and ready for grid interruption using mode. solar or grid power. If the battery is not fully charged, all 2-5.
General Information solar array than is needed by local loads, the inverter Figure 2-12. When local demand exceeds available stores the energy in the battery for later use. solar-generated power, the battery supplies power to support local loads. If the building requires more power than the battery and solar can provide, then the excess demand is drawn from the grid.
Page 15
General Information Sell Export Override Sell mode commands the system to export all available NOTE: This feature requires CTs to be properly installed power to the grid. Any connected batteries drain to the and calibrated prior to use. For more information on CT grid until their state of charge reaches the MinSoCRsrv calibration, see the PWRcell Inverter Installation Manual.
Page 16
General Information This page intentionally left blank. Owner’s Manual for Generac PWRcell Inverter...
Operation Section 3: Operation Operation and User Interface NOTE: A system mode can be changed at any time. To select a system mode: 3-1. Generac PWRcell is controlled through Figure the PWRcell inverter control panel. The inverter control 1. See Figure 3-3.
Operation Mod. Settings Menu Most REbus devices have user-adjustable parameters, PWRcell 2P Inv. such as setpoints for charge, startup voltage, or PLM Inverter channel. See Table 3-4 for available settings. Disabled To access user-adjustable parameters: 1. Use the left and right arrows to navigate to the AC Power: desired device page.
Page 20
Operation Table 3-4. Inverter Device Settings Setpoint Range Default Description Channel for REbus communications. All devices in a system must use the same channel (except REbus Beacon). Do not set equipment to channel 0 PLM_Channel 0 - 12 unless performing Multiple Inverter System Commissioning Procedure.See installation manual for more details.
Operation Ethernet Configuration PEEL AWAY Ethernet Setup For the inverter to communicate with the Generac server an Ethernet cable with a valid Internet connection must be plugged into the inverter Ethernet port. • REGISTER YOUR SYSTEM A blue Internet LED indicates the inverter has a successful connection to the PWRview server.
Page 22
Operation This page intentionally left blank. Owner’s Manual for Generac PWRCell Inverter...
Installation Manual for information and instructions on service and field-replaceable parts. One of the biggest reducers of system performance is dirty solar panels. Generac Power Systems, Inc. 0009890 recommends solar panels be cleaned regularly by a qualified person to ensure optimum performance and Figure 4-1.