LTE TDD
BBU3900&BBU3910 Description
2.6 Input Power
Table 2-3 Input power
Item
Input power
2.7 Physical Specifications
Table 2-4 Physical specifications
Item
Dimensions (height x
width x depth)
Weight
2.8 Environmental Specifications
Table 2-5 Environmental specifications
Item
Working temperature
Relative humidity
Ingress Protection (IP) rating
Atmospheric pressure
Issue 01 (2018-02-05)
Specifications
–48 V DC (voltage range: –38.4 V DC to –60 V DC)
Specifications
86 mm x 442 mm x 310 mm (3.46 in. x 17.40 in. x 12.20 in.)
≤ 15 kg (33.08 lb) (in full configuration)
Specifications
–20°C to +55°C (–4°F to +131°F) (long term)
+55°C to +60°C (131°F to 140°F) (short term)
NOTE
Short term indicates that a base station does not work for over
15 days within a year or that a base station does not
continuously work for over 72 hours.
5% RH to 95% RH
IP20
70 kPa to 106 kPa
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Technical Specifications
24