Westinghouse iGen4500c User Manual

Westinghouse iGen4500c User Manual

Digital inverter generator
Hide thumbs Also See for iGen4500c:

Advertisement

SAFETY
USER MANUAL
iGen4500
c
Digital Inverter Generator
Gasoline: 3700 Running Watts | 4500 Peak Watts
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iGen4500c and is the answer not in the manual?

Questions and answers

Summary of Contents for Westinghouse iGen4500c

  • Page 1 SAFETY USER MANUAL iGen4500 Digital Inverter Generator Gasoline: 3700 Running Watts | 4500 Peak Watts DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance, please call customer service at 855-944-3571.
  • Page 2: Table Of Contents

    The illustrations used in this manual are intended as representative reference views only. We reserve the right to make any specification or design change without notice. 2 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 3: Specifications

    Westinghouse Outdoor Power Warranty registration 777 Manor Park Drive Columbus, OH 43228 For Your Records Date of Purchase: Model Number: Serial Number: Place of Purchase: IMPORTANT: Keep your purchase receipt for trouble-free warranty coverage. Westinghouse Outdoor Power Equipment, LLC | 3...
  • Page 4: Safety

    Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended. 4 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 5: Safety Instructions

    Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Westinghouse Outdoor Power Equipment, LLC | 5...
  • Page 6 • Gas has a distinctive odor, this will help detect potential leaks quickly. • Gas vapors can cause a fire if ignited. • Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin. 6 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 7: Co Sensor

    A CO sensor fault can only be detectors in your home indicate an alarm, get to fresh diagnosed and repaired by an authorized air immediately. Call emergency services. You may have Westinghouse service center. carbon monoxide poisoning. ACTION LABEL Westinghouse Outdoor Power Equipment, LLC | 7...
  • Page 8: Safety Labels And Decals

    SAFETY SAFETY LABELS AND DECALS 8 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 9: Components

    10. Muffler and Spark Arrestor: The spark arrestor 5. Carry Handles: Built-in handles allow easy, two- prevents sparks from exiting the muffler. person transport. 11. Model Information Label: Provides model serial number, voltage/amps, and power rating information. Westinghouse Outdoor Power Equipment, LLC | 9...
  • Page 10: Control Panel Components

    12. Fuel Switch: Used to turn gas valve open or closed. 10 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 11: Assembly

    See Engine Oil Level Check in the Maintenance section. 3. Replace the oil dipstick and hand-tighten. 4. Replace the oil access cover. Westinghouse Outdoor Power Equipment, LLC | 11...
  • Page 12: Fuel

    Always mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system. 12 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 13: Generator Location

    DO NOT place the generator near vents Read and understand all safety information before starting or intakes where exhaust fumes could be drawn into the generator. occupied or confined spaces. Carefully consider wind and air currents when positioning generator. Westinghouse Outdoor Power Equipment, LLC | 13...
  • Page 14: Operation

    The remote start key fob included with the generator should be attached to the recoil handle or control panel. If your GROUNDING unit was shipped without a key fob, contact Westinghouse customer service. The generator can be started remotely from up to 99 feet Shock hazard.
  • Page 15: Fuel Switch

    If no load is present, the generator RPM will drop c. Push-Button Start: Push and hold the engine start to idle speed. The generator will detect loads as they are button for two seconds. applied and increase engine RPM. Westinghouse Outdoor Power Equipment, LLC | 15...
  • Page 16: Ac Circuit Breakers

    *Wattages listed are approximate. Verify actual wattage. 4. Verify that the intended running and surge loads do not exceed the generator’s capacity. 5. Reconnect electrical loads sequentially, allowing the generator to stabilize after each load is connected. 16 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 17: Power Management

    Always use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery. Westinghouse Outdoor Power Equipment, LLC | 17...
  • Page 18: Parallel Operation

    CAUTION Parallel operation allows you to link the iGen4500c to a Weight hazard. Always have assistance when lifting the compatible Westinghouse Inverter Generator for combined generator.
  • Page 19: Maintenance

    Note: The air filter element is oil soaked. Use an appropriate cleaning container. NOTICE Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water. Westinghouse Outdoor Power Equipment, LLC | 19...
  • Page 20: Engine Oil Level Check

    8. Install the oil access cover. conditions or in extremely hot weather, change the oil more frequently. Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions. 20 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 21: Engine Oil Change

    10. Connect the spark plug wire and install the engine as additional 3/8 to 1/2 turn with the spark plug wrench. service cover. 9. Install the spark plug boot and engine service cover. Westinghouse Outdoor Power Equipment, LLC | 21...
  • Page 22: Spark Arrestor Service

    30–60 minutes of use. If you do not regularly run the generator, charge the battery overnight once a month to keep it ready for use. Charge the battery in a dry location. 22 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 23: Storage

    5. Push the battery switch to the OFF position. 6. Disconnect the battery quick-connect plug. 7. Remove the spark plug. Westinghouse Outdoor Power Equipment, LLC | 23...
  • Page 24: Valve Clearance

    Hold the rocker arm pivot and retighten the pivot adjusting nut to the specified torque. Torque: 106 inch-pound (12 N•m) 8. Perform this procedure for the other valve. 9. Install the gasket, rocker arm cover, and spark plug. 24 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 25: Troubleshooting

    Replace or repair tool or appliance. Stop and Faulty power tool or appliance. No power at AC receptacles restart the engine. Contact Westinghouse customer service toll- Faulty generator. free at 1 (855) 944-3571. Westinghouse Outdoor Power Equipment, LLC | 25...
  • Page 26: Exploded View And Parts Lists

    EXPLODED VIEW EXPLODED VIEW AND PARTS LISTS ENGINE EXPLODED VIEW 26 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 27: Engine Parts List

    HI-VOLTAGE PKG MOUNTING BRACKET 4.10 94007 OIL DRAIN BOLT WASHER 16.4 90016 NUT M6 4.11 94035 OIL DRAIN BOLT WASHER 335803 TEMPERATURE SENSOR 4.12 91831 OIL DRAIN SOLENOID CENTRIFUGAL FAN HOUSING ASSEM- CRANKSHAFT ASSEMBLY Westinghouse Outdoor Power Equipment, LLC | 27...
  • Page 28 CROSS SCREW STUD M4 23.11 249934 WATERPROOF COVER RESONANT CAVITY ASSEMBLY 24.1 337001 RESONANT CAVITY 24.1.1 5697 FOAM FILTER 24.2 249919 PLUG 24.3 95602 BREATHER TUBE 24.4 94407 FUEL LINE CLAMP 97109 SPARK PLUG 28 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 29: Generator Exploded View

    EXPLODED VIEW GENERATOR EXPLODED VIEW Westinghouse Outdoor Power Equipment, LLC | 29...
  • Page 30: Generator Parts List

    9222 ROCKER SWITCH 9.14.1 503033 PULL ROD SEAT 8.1.2 9223 ONE PUSH BUTTON SWITCH 9.14.2 503035 PULL ROD 8.1.3 9224 ECO SWITCH 9.14.3 91334 BOLT M6X30 8.1.4 9079 WATERPROOF CAP RIGHT FRAME ASSEMBLY 30 | Westinghouse Outdoor Power Equipment, LLC...
  • Page 31 BRACKET 16.4 503009 HANDLE 16.5 503042 BRACKET 16.6 91330 BOLT M6 BRACKET ASSEMBLY 17.1 91325 BOLT M6 17.2 503007 LIFTER 17.3 503008 BRACKET 17.4 503009 HANDLE 17.5 503011 BRACKET 17.6 91335 BOLT M6 Westinghouse Outdoor Power Equipment, LLC | 31...
  • Page 32: Schematics

    SCHEMATICS SCHEMATICS SCHEMATICS 32 | Westinghouse Outdoor Power Equipment, LLC...

Table of Contents

Save PDF