Greenbrook T205-C Fused Timer Spur Switch - Grant QR Range Installation, Servicing And User Instructions Manual

Ntegrated indirect heat pump cylinder
Table of Contents

Advertisement

APPENDIX B
B.1
GENERAL INFORMATION
Grant QR pre-plumbed indirect heat pump cylinders are supplied
with a Greenbrook T205-C timer factory fitted, to control the
operation of the immersion heater for anti-legionella purposes.
Please refer to Grant UK DOC 0136 for detailed information on
anti-legionella regimes.
Please refer to Section B.3 and Section 5 of these instructions for
wiring details.
B.1.1
TECHNICAL INFORMATION
Make and model
Display
Working voltage
Rated impulse voltage
Operating temperature
Operation
Max load:
Resistive
Inductive
Isolation switch
Conforms to
Working environment
Pollution degree
B.2
OPERATING INSTRUCTIONS
'ON' indicator
Program
light
Button
Fuse
Double Pole
Holder
Isolation Switch
Figure B-1: Greenbrook T205-C Fused Timer Spur Switch
B.2.1
RESET THE DEVICE
1.
To fully reset this unit press the recessed 'Reset' button with
an insulated probe (see Figure B-1).
2.
A full display will show when the battery is charged, then
revert to the default screen (- - : - -). No display indicates that
the battery requires charging for a minimum 3 hour period.
See Figure B-2 for a representation of the screen's "full
display".
Page 36
GREENBROOK T205-C FUSED TIMER
SPUR SWITCH
Greenbrook -
T205-C
LCD
230V - 50Hz
2500V
-5°C to +40°C
Integrated control
13 Amps
6 Amps
Double pole isolation
BS 1363-4:1995+A4:2012,
BS EN 60730-1:2011,
BS EN 60730-2-7:2010.
Indoor use only
2
'+'
Reset
Button
Button
Time
Button
' - '
Button
Front Cable
Entry
Appendix B: Greenbrook T205-C Fused Timer Spur Switch
Figure B-2: Full display
B.2.2
SETTING THE DAY OF WEEK AND TIME
! NOTE !
Time setting is 24 hour mode.
1.
Press the 'Time' button for 2 seconds. (See Figure B-1). The
day of the week will start flashing (see Figure B-3).
Figure B-3: Setting day of the week
2.
Use the '+' or '-' button to change the display to the correct
day of the week.
3.
Press the 'Time' button (see Figure B-1) and the hour digits
will flash (see Figure B-4).
Figure B-4: Setting time of day (hours)
4.
Use the '+' or '-' buttons to set the hours.
5.
Press the 'Time' button (see Figure B-1) and the minutes will
flash (see Figure B-5).
Figure B-5: Setting time of day (minutes)
6.
Use the '+' or '-' buttons to set the minutes.
7.
Press the 'Time' button to save the setting and return to
operating mode.
! NOTE !
If '+' or '-' button is held for more than 2 seconds, the
selected time digit will add or decrease quickly (about 5
steps per second), if no key is pressed within 60 seconds
the display will return to operating mode.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QR Range and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Qrintsc210