Technical Specification - LG WH20S F5 Owner's Manual

Hide thumbs Also See for WH20S F5:
Table of Contents

Advertisement

Technical specification

Description
Tank Capacity
Dimension (Width x Height x Depth)
Weight empty
Diameter of water connections
Diameter of condensate drainage connections
Type of corrosion protection
Type of internal tank protection
Max Working pressure
Setting range of the water temperature
Operating temperature range of the heat pump
Refrigerant R134a
Refrigerant volume in equivalent tonnes
Refrigerant design pressure (high side / low side)
Voltage
Frequency
Total Max power consumption
Max power consumption by heat pump
Max power consumption by heating element
Protection rating
Air flow rate (H/M)
Available static pressure
Unit
WH20S F5
L
200
mm
580 x 1625 x 582
kg
100
-
-
-
Impressed Current Cathodic protection
-
MPa
°C
°C
kg
0.65
T.eq.CO
0.930
2
MPa
Power supply
V
Hz
W
W
W
Air side
m
/min
6.7/4.4
3
Pa
90
EN
WH27S F5
270
580 x 2008 x 582
119
G 3/4"
3/4" 1/2"
Ceramic coated
1
35 to 60
-5 to 50
0.75
1.072
2.0 / 0.9
230
50
2600
550
2050
IPX1
6.7/4.4
90
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WH20S F5 and is the answer not in the manual?

Questions and answers

Pieter Wellens
April 13, 2025

Can I install lg dry contact on wh20s heat pump booler

This manual is also suitable for:

Wh27s f5

Table of Contents