Delta Elektronika SM6000 Series Manual
Delta Elektronika SM6000 Series Manual

Delta Elektronika SM6000 Series Manual

Hide thumbs Also See for SM6000 Series:

Advertisement

DELTA ELEKTRONIKA B.V.
DC POWER SUPPLIES
SM6000 - series
 SM15-400
 SM30-200
 SM45-140
 SM60-100
 SM70-90
 SM120-50
 SM300-20
 SM600-10
Product Manuals and Driver & Example Software
For several Applications, build-in Options and Interfaces there are Application
Notes, separate Product Manuals and Driver & Example Software available on
available on our website. See PRODUCTS\SM6000\DOWNLOADS.
PRODUCT MANUAL
Contents:
1
Safety Instructions
2
Sicherheitshinweise
3
General
4
Installation
5
Trouble Shooting
6
Maintenance & Calibration
7
EU Declaration of Conformity
1 / 21
Vissersdijk 4, 4301 ND
Zierikzee, the Netherlands
DELTA ELEKTRONIKA B.V.
www.DeltaPowerSupplies.com
Tel. +31 111 413656
rev. Nov. 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM6000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta Elektronika SM6000 Series

  • Page 1 DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 SM6000 - series  SM15-400  SM30-200  SM45-140  SM60-100  SM70-90  SM120-50  SM300-20  SM600-10 Product Manuals and Driver & Example Software For several Applications, build-in Options and Interfaces there are Application Notes, separate Product Manuals and Driver &...
  • Page 2 Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
  • Page 3 SAFETY INSTRUCTIONS SM6000 1.10 Parts Substitutions & Modifications Parts substitutions and modifications are allowed by authorized Delta Elektronika service personnel only. For repairs or modifications the unit must be returned to a Delta Elektronika service facility. 1.11 Removal of (safety) covers Safety cover(s) are used to cover potentially hazardous voltages.
  • Page 4 Die Nichteinhaltung der Sicherheitsvorkehrungen oder Warnungen in diesem Dokument verstößt gegen die Sicherheitsstandards im Hinblick auf Bauart, Produktion und vorgesehene Nutzung dieses Geräts und kann die eingebauten Schutzvorrichtungen beschädigen. Delta Elektronika haftet nicht dafür, wenn der Nutzer diesen Anforderungen nicht nachkommt.
  • Page 5 Spannungsquellen entfernen und Stromkreise entladen. 2.10 Teileaustausch & Modifikationen Teileaustausch und Modifikationen sind ausschließlich autorisiertem Delta Elektronika-Service-Personal gestattet. Reparaturen oder Modifikationen am Gerät dürfen nur durch eine Delta Elektronika-Serviceeinrichtung durchgeführt werden. 2.11 Entfernung von (Sicherheits-) Abdeckungen Sicherheitsabdeckung(en) werden verwendet, um potenziell gefährliche Spannungen abzudecken. Beachten Sie Folgendes, wenn Sie die Sicherheitsabdeckung(en) entfernen: ...
  • Page 6: Ac Input Voltage

    3 - 3  The DC output ripple is very low with almost no spikes. The Measuring ripple voltage RIGHT! specified ripple voltage is measured directly on the DC power 6 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 7: Analog Programming

     With the ISO AMP CARD earth loops between the unit and the programming source are prevented. 3.11 ETH / IEEE488 / RS232 PROGRAMMING  The Delta Elektronika PSC-ETH, PSC-488 and PSC-232 controllers can be factory installed inside the unit.  Voltage and current can easily be programmed and read back.
  • Page 8: Status Outputs

    A. Once the unit is switched on, the voltage and current can be set to the preferred value. * = SW1-5 only on SM300-20 / SM600-10 and on units with optional digital encoders (option P220). 8 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 9 2500 Vrms. Since the insulation of DC fig 3 - 15 power terminals -> case is 600 VDC, the insulation of the Insulation test voltages. primary components to case will break down when 3750 Vrms 9 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 10: Thermal Protection

    Remote sensing, voltage drop in load leads subtracts on the DC output terminals. from maximum output.  The sense leads are protected against accidental interruption. 10 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 11: Series Operation

    3 - 21 The Master / Slave combination can also be programmed with the interfaces PSC-488 or the PSC-232. fig 3 - 22 Use standard UTP cables (RJ45) for Master / Slave operation. 11 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 12  Note: The control circuit makes the fan start in a pulsating mode, during which period it can produce a high pitched sound. This is normal. 3.36 DIMENSIONS fig 3 – 25 Unit dimensions. 12 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 13: Installation

    Low resistive cable connection by mounting the  A voltage should now be present on the output. cables directly on the DC output strips.  By pressing the DISPLAY CV/CC SETTING button the meters 13 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 14 The Ø of the prog. input (pin 1) is internally connected to the Local sensing. S–, the S– is connected to the negative output. To protect the internal wiring a 650 mA self-resetting fuse is connected in 14 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 15  The Over Voltage Limit measures the voltage on the output terminals, so the OVL setting should be increased by the total voltage drop in the load leads. fig 4 - 8 Charging a battery with a circuit breaker in series. 15 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 16: Battery Charger

     After turning the units on again, the slaves will be in Remote fig 4 - 11 CC mode and the Keylock (see previous paragraph 5) is Master / Slave parallel connections. activated. This is because the unit automatically detects the 16 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 17 CC-mode. The parallel slave must be in Remote CC-mode and the CV-potmeter must be fully opened.  Note: A Master / Slave combination can always be programmed, also with the IEEE488/RS232 controller (PSC- 488 / PSC-232). 17 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 18: Troubleshooting

    5 - 1. To check the fuse measure the voltage between Ø and the minus output, a high voltage means too much current flowing through the fuse. F27_2 = 650 mA, self resetting. 18 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 19  This indicates the Keylock function is activated, see previous paragraph 5) in "operating manual". 5.14 NO LEDS on  Check input.  Do not try to repair, but send for repair. See paragraph 1). 19 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 20: Maintenance And Calibration

    CC mode. Calibrate the current with R26_41 exactly on the rated maximum current. fig 6 -3 Warning! Wrong calibration can damage the unit. Calibrating maximum current and offset on P597. 20 / 21 DELTA ELEKTRONIKA B.V. rev. Nov. 2020...
  • Page 21 EU DECLARATION SM6000 DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 EU Declaration of Conformity – SM6000 - series Delta Elektronika Vissersdijk 4 4301 ND ZIERIKZEE The Netherlands Declare under sole responsibility that the following Power Supplies:...