Page 1
Dura-Glide™ Series, Dura-Storm™ Series, Dura-Guard™ Series, DuraFit™, and IS10000 Automatic Sliding Door Systems Operation and Maintenance Manual...
Table of Contents To Our Customers ............................2 General Information ............................. 3 Service Availability ........................... 3 Limited Warranty ..........................3 Compliance with Industry Standards ....................3 Contact Information ............................3 Caution ................................4 Operation ..............................5 Function Switches ..........................5 Emergency Breakout ........................
To Our Customers: We’ve provided you with an owner’s manual to familiarize you with your automatic door system. It is essential that you “know your system”, how it operates and how to maintain it to be compliant with the industry standards for safety. It is your responsibility, as owner or caretaker of the equipment, to inspect the operation of your door system on a daily basis to ensure that it is safe for all door users.
General Information Service Availability STANLEY Access Technologies LLC products are distributed through a nationwide network of STANLEY- owned branch locations and authorized distributors that specialize in Sales, Installation and Service of automatic door systems. Our Service programs offer ongoing support such as regularly scheduled preventive maintenance, or if required, emergency service 24 hours a day, 365 days a year.
Should the door fail to operate as prescribed in the “Daily Safety Check”, or at any other time for any reason, do not attempt to repair or adjust the door. Discontinue operation of the door and call for service by a STANLEY certified service technician.
Operation Function Switches: The function switches for the door operator are located on the underside of the door header or on the jamb of the stationary panel (see diagram). The function switches are: • Power Switch – this switch is illuminated a red color when the power is on. This switch should not be turned off unless the door is being serviced.
5. As mentioned above, ensure that there are no bulletin boards, literature racks, displays, or other attractions that could impede the operation of the door panels. Stanley Access Technologies recommends that you clean the automatic door system using the Cleaning following procedure: 1.
Automatic Sliding Door Decals Sliding doors servicing ingress or egress must be marked with directional decals. The arrow sign must be visible from the approach side and an international “DO NOT ENTER” must be visible from the other side. These door decals must be affixed on the door 50” +/‐ 12” from the finished floor. KNOWING ACT DOORS –...
TERMINOLOGY DRAWING AND INDEX 1. Activating Zone – The detection pattern (zone) 7. Recycle – When a door is closing and it is activated, it of approximately five feet deep and as wide as immediately reverses and goes to its “open” position. the clear door opening protected by the motion 8.
DAILY SAFETY CHECK For Your Customers’ Safety and Your Own Protection Perform This Safety Check on Each Automatic Sliding Door Each Day And After Any Power Outage or Generator Test 1. Check electronic sensor by walking toward the door opening from several angles. SLIDE DOOR SYSTEMS WITH ELECTRONIC CONTROLS The door should start opening when you are about five feet from the door.