  • Page 1 PORTABLE AIR CONDITIONER MODEL NO: AC10050 PART NO: 3230575 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0120 - ISS 1...
  • Page 2: Environmental Protection

    GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS • Carefully read the instructions before operating the unit • This air conditioner is for indoor use only. • This air conditioner must be only connected to a 230 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the air conditioner is used.
  • Page 4 • The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. • Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off.
  • Page 5 ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS • Do not cover or restrict the airflow from the outlet or inlet grills. • For maximum performance the air conditioner should be situated at least 50 cm from the walls or other objects. •...
  • Page 6: Electrical Connections

    ELECTRICAL CONNECTIONS WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY. Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230 V AC 50Hz.
  • Page 7 OVERVIEW DESCRIPTION DESCRIPTION Air Outlet Flap Side Air Filter Frame Control Panel Power Cable Storage Hooks Handle Drainage Cap and Plug Rear Air Filter Frame (Air Intake) Plug Storage Socket Air Outlet Port (for ducting) Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 8: Control Panel And Remote Control

    CONTROL PANEL AND REMOTE CONTROL 1. Power Button Press the button to turn the air conditioner ON/OFF. 2. Swing Button Pressing the swing button makes the louvres move up and down. 3. Speed Button Press the speed button to select between High / Mid / Low speed.
  • Page 9: Installation

    2. Exhaust Duct Set 3. Remote Control Unit (including 2 x AAA batteries) 4. Window Kit Should any loss or damage be apparent, please contact your CLARKE dealer immediately. INSTALLATION IMPORTANT: Do not position your air conditioner where it will be exposed to sources of heat above 35 1.
  • Page 10 5. Move the air conditioner into position and extend the flexible exhaust duct to suit your window layout. NOTE: The length of the exhaust duct is variable between 480 mm and 1500 mm (adaptors included). Using a shorter length of ducting uses less energy.
  • Page 11: Fitting Batteries

    FITTING BATTERIES 1. Slide the battery cover away as indicated by the arrow on the rear of the remote control. • Fit 2 x AAA batteries into the battery compartment following the polarity diagram inside. OPERATION GENERAL OPERATION • If the room is exposed to direct sunlight, draw any curtains during the sunniest part of the day.
  • Page 12: Fan Mode (Fan)

    FAN MODE (FAN) 1. Press the mode button repeatedly to select FAN. • The FAN indicator lamp lights up. 2. Press the speed button to select between High / Mid / Low speed. NOTE: In fan mode, you cannot set the temperature.
  • Page 13: Timer Mode

    The following fault codes can be displayed on the control panel. Code Diagnosis of Fault Action Required Coil temp is abnormal. Return to CLARKE Service Department. Room temp is abnormal. Return to CLARKE Service Department. Anti-freezing protection. None, will recover automatically when...
  • Page 14: Draining Off The Water

    DRAINING OFF THE WATER MANUAL DRAINAGE: 1. When the internal water tank is full, the unit will stop working and show “FL” on the display panel. 2. Turn off the unit using the power button and unplug from the mains. Try not to move the air conditioner abruptly as this may cause water to spill out from the internal water tank.
  • Page 15: Maintenance

    MAINTENANCE CLEANING WARNING: PLEASE SHUT OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE. 1. Clean the outside surfaces of the unit with a duster or a soft, moist cloth. • Do not use solvents which could damage the plastic components. CLEANING THE AIR FILTERS Clean the air filters every 2 weeks.
  • Page 16: Troubleshooting

    END OF SEASON CLEANING If the air conditioner is not going to be used for a long time: 1. Drain the internal water tank (page 14). 2. Run the air conditioner in fan mode for 2 hours to dry out the inside. 3.
  • Page 17: Parts Diagram

    PARTS DIAGRAM Number Description Part Number Air Filter ZYEAC1005062 Air Filter ZYEAC1005063 Remote control ZYEAC1005065 Air exhaust flat nozzle ZYEAC1005066 Air exhaust hose ZYEAC1005067 Air exhaust joint ZYEAC1005068 Window sealplate assembly ZYEAC1005069 Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 18: Technical Specifications

    TECHNICAL SPECIFICATIONS AC10050 Model Number Power Supply 230V/50Hz Weight 25 kg Dimensions (L x W x H) 340 x 443 x 815 mm Water Sump Capacity 0.55 L Air Flow Volume 360 m Operating Temperature 15 - 35 Exhaust Duct Diameter 150 mm Exhaust Duct Length (expanded) 1500 mm...