Friedrich FSHSR09A1A Installation And Operation Manual

Friedrich FSHSR09A1A Installation And Operation Manual

Outdoor unit

Advertisement

Models
Outdoor Unit FSHSR09A1A FSHSR12A1A
FSHSR18A3A FSHSR24A3A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSHSR09A1A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Friedrich FSHSR09A1A

  • Page 1 Models Outdoor Unit FSHSR09A1A FSHSR12A1A FSHSR18A3A FSHSR24A3A...
  • Page 3: Table Of Contents

    Content Operation Notices Precautions ......................1 Parts Name ......................6 Installation Notice Installation dimension diagram ................7 Safety precautions for installing and relocating the unit ........8 Tools for installation ....................9 Selection of installation location Requirements for electric connection ..............10 Installation Installation of outdoor unit ..................11 Vacuum pumping ....................15 Leakage detection ....................15 Check after installation ..................16...
  • Page 4 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 5: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 7 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 8 Precautions WARNING Do not power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 9 Precautions WARNING Caution: This equipment is not intended for use during construction. The use of equipment during construction could result in premature failure of the components and/ or system and is in violation of our standard warranty guidelines and may result in the suspension or termination of the warranty.
  • Page 10: Parts Name

    Parts Name Outdoor Unit air inlet Connection wire air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 11: Installation Dimension Diagram

    Installation dimension diagram Space to the obstruction Air inlet side 12in Above Space to the wall 20in Above Air outlet side Space to the wall Drainage pipe...
  • Page 12: Safety Precautions For Installing And Relocating The Unit

    Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
  • Page 13: Tools For Installation

    Tools for installation 1 Level 2 Screw driver 3 Impact drill 5 Pipe expander 4 Drill 6 Torque wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 14 Measuring tape Note: Selection of installation location Indoor unit Basic requirement Outdoor unit...
  • Page 14: Requirements For Electric Connection

    Requirements for electric connection Safety precaution  )ROORZ ORFDO DQG QDWLRQDO HOHFWULFDO FRGHV ZKHQ ZLULQJ  (QVXUH SURSHU ZLUH VL]LQJ  )ROORZ ZLULQJ GLDJUDPV  %H VXUH WR GLVFRQQHFW SRZHU EHIRUH SHUIRUPLQJ LQVWDOODWLRQ RU PDLQWHQDQFH  5HIULJHUDQW FDQ RSHUDWH DW YHU\ KLJK WHPSHUDWXUHV 3OHDVH EH VXUH WR NHHS ZLUHV VHSDUDWH IURP SLSLQJ Grounding requirement  (QVXUH SURSHU JURXQGLQJ...
  • Page 15: Installation Of Outdoor Unit

    Installation of outdoor unit Step one: Mounting of the outdoor unit 1. Select installation base on building material. 2. Choose the correct mounting hardware for application. and operable manner. above the ground for heat pump operation, this will allow proper water drainage. anchors for your mounting material.
  • Page 16 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw cap of valve and 3. Tighten the union nut with torque aim the pipe joint at the bellmouth of wrench by referring to the sheet pipe.
  • Page 17 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip. Note: 1HYHU FXW WKH SRZHU FRQQHFWLRQ ZLUH WR SURORQJ RU VKRUWHQ WKH GLVWDQFH Step six: Arrange piping 1. The pipes should be placed along the wall, bent reasonably and hidden wall 2.
  • Page 18 Installation of outdoor unit The 18K、24K UNIT drainage hole consists of two Φ25 and two kidney holes (see the fig.1). The drain plug consists of one Φ25 and two kidney plugs. (The figures in this manual may be different with the material objects, please refer to the material objects for reference) Drain plug drain...
  • Page 19: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on 0DQLIROG *DXJH the liquid valve and gas liquid valve valve and the nut of refri- gas valve gerant charging vent. refrigerant valve cap 2. Connect the charging hose charging SRUW 0DQLIROG *DXJH to the refri- gerant charging SRUW of gas nut of refrigerant...
  • Page 20: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 21: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● IW IWIW 2.Min. length of connection pipe is )W. 3.Max. length of connection pipe. Unit: IW Max length of connection pipe Max length Max length Cooling Cooling of connec- of connec- capacity capacity...
  • Page 22 Configuration of connection pipe Diameter of connection pipe Outdoor unit charge Liquid pipe Gas pipe Cooling and heating(oz/g) ' ' 8 ' ' 2 0.71 1/4'' 1/4'' or 3/8'' ' ' 8 ' ' 4 1.76 1/2'' ' ' 4 ' ' 8 4.23 5/8''...
  • Page 23: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ([SDQG WKH SRUW ZLWK H[SDQGHr. the distance of indoor unit and hard outdoor unit.
  • Page 24 Friedrich Air Conditioning Co. 10001 Reunion Place, Suite 50 ‡ 6an Antonio, Texas 78216 1.800.541.6645 www.friedrich.com 66129933951...

This manual is also suitable for:

Fshsr12a1aFshsr18a3aFshsr24a3a