INSTALLATION INSTRUCTIONS
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6".
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
NOTE: Save these instructions for future reference.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.

LUMINAIRE MOUNTING:

1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Dig a hole approximately 9" diameter by 12" deep at selected location.
3. Insert bollard post into hole 12" deep.
4. Strip two leads from luminaire pigtail. Using two silicone filled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
5. Provide power to luminaire and check for proper operation.
6. Support bollard post in selected location and back fill with soil.
NOTE: All luminaires orientation must be so that every part of the lampholder
and the lamp are greater than 2" from the ground plane.

CONCRETE POUR INSTALLATION:

NOTE: Pour concrete installation requires conduit sleeve as to allow 36" pigtail
to exit through concrete footing.
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Dig a hole approximately 9" diameter by 12" deep at selected location.
3. Insert bollard post into hole 12" deep.
4. Run conduit sleeve into bollard post.
5. Strip the two (2) leads from the luminaire pigtail. Using the two (2) silicone
filled safety connectors (provided), connect the leads from the luminaire to the
main supply cable leads.
NOTE: Luminaires are supplied with 36" of 18-2 cable pigtail for secure
connection to the main supply cable. The wire is to be protected by routing in
close proximity to the luminaire. The wiring should be buried a maximum depth
of 6 inches (15.2 cm) in order to connect to the main supply cable.
6. Provide power to the luminaire and check for proper operation.
7. Using standard masonry procedures, support bollard post in selected
location and pour concrete making sure exited end of conduit sleeve reaches
outside concrete.
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
6" of 18-2 cable pigtail for secure
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • email@vistapro.com • www.vistapro.com
Shade
Bollard Post
36" Pigtail
Silicone Filled
Safety Connectors
Cover screws
Bollard Post
12" Post Extension
for Mounting Base
9225
Landscape Series
Bollards & Beacons
12" Post Extension
for Mounting Base
Main Supply Cable
Soil
Shade
Concrete
Soil
Conduit Sweep

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Landscape Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Vista Landscape Series

  • Page 1 Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification. 1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
  • Page 2 LED: The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the first fixture to the last. Eliminating the dimness issues often attributed to voltage drop.

This manual is also suitable for:

9225

Table of Contents