PLEASE READ THIS IMPORTANT SAFETY INFORMATION
Products manufactured by Triton are safe and without risk provided they are installed, used and
maintained in good working order in accordance with our instructions and recommendations.
WARNING: DO NOT operate shower if frozen, or suspected of being frozen. It must thaw out
before using.
DO NOT operate the unit if the showerhead or spray hose becomes damaged.
DO NOT restrict flow out of shower by placing showerhead in direct contact with your body.
DO NOT operate the shower if water ceases to flow during use or if water has entered inside
the unit because of an incorrectly fitted cover.
WARNING: If restarting the shower immediately after stopping, be aware that a slug of
hot water will be expelled for the first few seconds.
GENERAL
This book contains all the necessary fitting and operating instructions for your electric shower.
1
1.1
Isolate the electrical and water supplies before
Care taken during the installation will provide a long, trouble-free life from your shower.
removing the cover.
1.2
Read all of these instructions and retain them
PLEASE READ THE GENERAL GUIDANCE NOTES BEFORE PROCEEDING.
for later use.
1.3
DO NOT take risks with plumbing or electrical
Triton recommend watching the short online *videos that cover electric shower basics before your
equipment.
installation -
1.4
Isolate electrical and water supplies before
*(videos may not show the exact model purchased)
proceeding with the installation.
• What is an electric shower?
1.5
The unit must be mounted onto the finished
wall surface (on top of the tiles). DO NOT tile
• Electrical requirements for electric showers
up to or seal around ANY PART of the unit
• Plumbing requirements for electric showers
using silicone sealer after fixing to the wall.
Special care must be taken NOT TO BLOCK
• Kilowatt ratings explained
OR SEAL ANY PRD VENTS ON THE UNIT.
1.6
Contact Customer Service (see back page), if
To view these videos visit:
any of the following occur:
a)
If it is intended to operate the shower at
pressures above the maximum or below the
PLEASE USE THE FOLLOWING CHECK LIST TO AID YOUR INSTALLATION
minimum stated.
b)
If the unit shows a distinct change in performance.
c)
If the shower is frozen.
SECTION
1
1.7
If it is intended to operate the shower in areas
Check that the water supply will satisfy requirements (page 2 & 6) ..........................
of hard water (above 200 ppm temporary
SECTION
hardness), a scale inhibitor may have to be
2
Check that water & cable entry points of the unit meet requirements (page 3) .......
fitted. For advice on the Scale Inhibitor,
contact Customer Service.
SECTION
3
1.8
The showerhead must be cleaned regularly
Check that the electric supply will satisfy requirements (page 4 - 5) .........................
with descalent to remove scale and debris,
SECTION
otherwise restrictions to the flow on the outlet
4
Siting of the shower (page 6 - 7)..............................................................................
of the unit will result in higher temperatures
and could also cause the (PRD) Pressure Relief
SECTION
5
Device in the unit to operate.
Plumbing installation (page 8) .................................................................................
1.9
This product is not suitable for mounting into
SECTION
steam rooms or steam cubicles.
6
Electrical installation (page 9) ..................................................................................
PLUMBING
2
SECTION
7
2.1 The plumbing installation must comply with
Fit to the wall & connect the shower supplies (page 9 - 13) .....................................
Water Regulations, Building Regulations or any
SECTION
particular regulations as specified by Local
8
Fitting the cover (page 13 - 14) ...............................................................................
Water Company or Water Undertakers and
should be in accordance with BS EN 806.
SECTION
9
2.2 The supply pipe must be flushed to clear debris
ONLY Commission the shower in the way described (page 15) ...........................
before connecting to the shower unit.
SECTION
10
Familiarise yourself with the user operating instructions (page 16 - 18) ....................
INTRODUCTION - PLEASE READ
.
www.tritonshowers.co.uk/triton-products/product-videos.aspx
2.3 DO NOT solder pipes or fittings within 300mm
of the shower unit, as heat can transfer along
the pipework and damage components.
2.4 DO NOT fit any form of outlet flow control as
the outlet acts as a vent for the heater can.
2.5 DO NOT use excessive force when making
connections to the flexible hose or
showerhead, finger tight is sufficient.
2.6 All plumbing connections must be completed
before making the electrical connections.
2.7 This appliance MUST not be connected to the
inlet supply by a hose-set.
ELECTRICAL
3
3.1 The installation must comply with BS 7671
'Requirements for electrical installations' (IEE
wiring regulations), building regulations or any
particular regulations as specified by the local
Electrical Supply Company.
3.2 This appliance MUST be earthed.
3.3 In accordance with 'The Plugs and Sockets etc.
(Safety) Regulations 1994', this appliance is
intended to be permanently connected to the
fixed wiring of the electrical mains system.
3.4 Make sure all electrical connections are tight to
prevent overheating.
3.5 A 30mA residual current device (RCD) MUST
be installed in all UK electric and pumped
shower circuits. This may be part of the
consumer unit or a separate unit.
3.6 Switch off immediately at isolating switch if
water ceases to flow during use.
3.7 Other electrical equipment i.e. extractor fans,
pumps must not be connected to the circuits
within the unit.
3.8 Switch off at isolating switch when not in use.
This is a safety procedure recommended with
all electrical appliances.
3.9 As with all electrical appliances it is
recommended to have the shower and
installation checked at least every two years by
a competent electrician to ensure there is no
deterioration due to age and usage.
2
Tick off as
you complete
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T80 Easi-fit and is the answer not in the manual?

Questions and answers

Dorian Kelly
January 22, 2025

T80+ The system runs cold on first swich on ( OK water pressure) unless the temperature knob is fully against the stop , turning clockwise. Once the water runs warm, the knob can be turned back to the correct position. Can this be repaired with a new part? ALTERNATIVELY: Is the upgrade to the Z version an exact change with fixings and inlets?

Brian Wills
January 25, 2025

I have just fitted a T 80 easy fit thermostatic unit and with all controls setto max the water is only luke warm

1 comments:
Mr. Anderson
February 10, 2025

The water may be lukewarm due to one or more of the following reasons:

1. Too much flow – Reduce the flow rate using the temperature control.
2. Low water pressure – Check if the water supply is mains or tank-fed.
- If tank-fed, consider replumbing to mains or installing a pump.
- If mains-fed, ensure the mains stop valve is fully open and there are no supply restrictions.
3. Reduction in ambient water temperature – Adjust the flow rate to reduce the flow and select ‘HIGH’ power.
4. Electrical issue – The unit may need to be checked by a qualified professional.

If the issue persists, contact Triton Customer Service for further assistance.

This answer is automatically generated

john
February 19, 2025

My Triton T80 has temperature variations despite constant water pressure. Shower goes from hot to ice cold in seconds. Remedy please

1 comments:
Mr. Anderson
February 19, 2025

Possible solutions for temperature variations in a Triton T80 Easi-fit shower include:

1. Water Too Hot:
- Clean or replace a blocked inlet filter.
- Reduce flow rate via temperature control.
- Select ‘ECONOMY’ power mode.
- Check and adjust mains water supply if necessary.

2. Water Cycling Between Hot and Cool:
- Follow the same steps as for "Water Too Hot."
- If the issue persists, contact Triton Customer Service.

3. Water Too Cool or Cold:
- Reduce flow rate via temperature control.
- Ensure the water supply is mains-fed and not tank-fed; if tank-fed, replumb to mains or install a pump.
- Confirm the mains stop valve is fully open and there are no supply restrictions.
- Increase ambient water temperature by adjusting flow rate.
- Select ‘HIGH’ power mode.
- If electrical issues are suspected, have the unit checked by a qualified professional.

This answer is automatically generated

Andy Clifton
March 2, 2025

Does the power light stay on all the time even when the shower is not working and switched off . My power button stays lit up all the time

1 comments:
Mr. Anderson
March 2, 2025

No, the power light on the Triton T80 Easi-fit only illuminates when the electricity supply to the shower is switched on at the isolating switch.

This answer is automatically generated

Michael Pritchard
March 10, 2025

t80 easy fit will not come on . Power is indicated from the feed to the unit. Why?

1 comments:
Mr. Anderson
March 10, 2025

The Triton T80 Easi-fit may not turn on despite power being indicated from the feed to the unit due to several possible reasons:

1. Showerhead or Hose Issue: If the showerhead or hose is damaged, the unit may not operate correctly.
2. Frozen Unit: If the shower is frozen or suspected of being frozen, it must be fully thawed before use.
3. Water Flow Issue: If water ceases to flow during use or does not reach the unit due to low pressure, restrictions, or a closed stop valve, the shower will not function.
4. Cover Fitted Incorrectly: If water has entered the unit due to an incorrectly fitted cover, the unit may not operate.
5. Electrical Fault: The unit may have an internal electrical issue that requires checking by a qualified professional.

If none of these resolve the issue, contact Triton Customer Service for further assistance.

This answer is automatically generated

Malcolm Darlington
March 17, 2025

Is the low pressure indicator red for normal use

1 comments:
Mr. Anderson
March 17, 2025

No, the low pressure indicator is not on during normal use. It only turns on when the water pressure falls below the minimum required for correct operation.

This answer is automatically generated