Automatic Fan Speed; Outdoor Fan Speed Control - Sanyo SAP–KR184GJ Technical & Service Manual

Split system air conditioner
Table of Contents

Advertisement

8-4. Automatic Fan Speed (Indoor Unit)
This automatically adjust the indoor fan speed for the room by the difference between the room temperature
and set temperature.
< Cooling>
T+2°c
T+1°c
Set temp.
T°c
Indoor fan

8-5. Outdoor Fan Speed Control

To optimize performance of the air conditioner, the outdoor fan speed is switched automatically according to the
outdoor temperature.
If the outdoor air temperature falls below 28.5°C, the fan speed switches to LOW.
If the outdoor air temperature rises above 31.5°C, the fan speed switches to HIGH.
This function does not become active in heating operation.
Outdoor air
temperature (°C)
Outdoor fan
speed
H
M
H:High
M:Medium
31.5
28.5
H
M
L
L:Low
L
31
Room temp.
H
H

Hide quick links: