Epson Stylus PHOTO RX600 Service Manual page 44

Hide thumbs Also See for Stylus PHOTO RX600:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX600/610, RX620/630
Pay attention when handling the connector while installing the
middle housing.
After installing the Middle Housing, remove the Tube Cover
once and make certain that the tube is inserted into the Porous
Pad properly.
1.
Remove the one screw securing the Tube Cover and remove the
Tube Cover.
2.
Check that the tube is inserted into the Porous Pad properly.
Tube Cover
C.B.P Tite 3X8,F/ZN
Tightening torque:0.6 ± 0.1 N
Disassembly and Assembly
Tube
Porous Pad
m
Main Unit Removal
Revision C