Sanyo SAP-K181A Technical & Service Manual page 7

System
Table of Contents

Advertisement

Indoor Unit
SAP – K241A
Outdoor Unit
SAP – C241A
Power Source
Voltage rating
Performance
Capacity
Air circulation (High)
Moisture removal (High)
Electrical Rating
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Features
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant
tube diameter
Refrigerant tube kit / Accessories
Dimensions & Weight
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks:
Rating conditions are:
Cooling :
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
BTU/h
Liters/h
Indoor / Outdoor
Horizontal
Vertical
Indoor : Hi / Me / Lo
Outdoor : Hi
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
kW
3
m
/h
V
A
W
%
W/W
A
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hours ON or OFF
g
dB-A
dB-A
m
Optional / Hanging wall bracket
Indoor Unit
mm
285
mm
995
mm
196
mm
276
mm
1,070
mm
363
kg
12.0
kg
15.0
0.11
m
3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
3
240V Single phase 50Hz
240 V
Cooling
6.3
21,500
830
3.3
Cooling
216 ~ 264
13.2
2,830
97
2.2
73
3 and Auto / Auto(Hi, Lo)
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R22 / 1,785
Capillary tube
43 / 41 / 39
54
Flare type
10
6.35(1/4)
15.88(5/8)
Outdoor Unit
630
810
275
704
953
369
59.0
62.0
0.25