TROUBLESHOOTING
4-2-12. If Water is not supplied
Checking method of Valve resistance (Must
power off for checking)
Resistance can be changed by input voltage.
CN70#1 (Red)
CN73#5 (White-black)
- resistance value ; 388Ohm
7%)
** 0 : Short trouble /
: Open trouble
typical PCB Ground CN1#3(Black)
Checking method of voltage
Based on PCB typical Ground CN1#3(Black)
1) Check voltage of IC73# (same voltage as
IC01#64)
- Water valve operating (about 5V 0.5V)
Based on PCB typical Ground CN1#3(Black)
2) IC73 #14 voltage
- Water valve operating (about 0.7V 0.5V)
3) Check the voltage of Water Valve operating
(AC voltage)
=> For checking the Relay RY7A operating.
CN70#1(Red)
CN73#5(White-black)
- ICE Water valve waiting (about AC 0V)
- ICE Water valve operating (about AC 110(230)V
Is the confirming sound of
the valve operation heard
when dispenser switch
pushed?
Is the valve unit normal?
Is the voltage of PCB IC01
MICOM #15 changed 0V~5V
according to switch On/Off?
Does Main PCB IC73 #3
have about 5V input?
Does Main PCB IC73 #14
have about 0.7V output?
Is the contact point of main
PCB RELAY RY7A normal?
MAIN PCB normal
-- Need to check the other parts
Check the wire between water
valve MAIN PCB
20%)
Ice water valve itself has
trouble or bad contact of
connector
Check the connection hose
72
Start
Normal(Check Ice
water valve hose)
Replace Valve
1) Check the dispensing
lever
2) Check switch unit/ wiring
connection
3) Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB

Hide quick links: