Page 1
Digital Blood Pressure Monitor Model UA-767F-W Instruction Manual Original Manuel d’instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione 使用手冊 翻譯 1WMPD4002905C...
Contents Dear Customers ..............2 Preliminary Remarks ............. 2 Precautions ................2 Parts Identification ..............5 Symbols ................6 Operation Mode ..............8 Using the Monitor ............... 10 Installing / Changing the Batteries ......... 10 Connecting the Air Hose ..........11 Connecting the AC Adapter ..........
Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
Page 4
Wireless communication devices, such as home networking devices, mobile phones, cordless phones and their base stations, walkie-talkies can affect this blood pressure monitor. Therefore, a minimum distance of 3.3 meters (11 feet) should be kept from such devices. When reusing the device, confirm that the device is clean. Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations.
Page 5
People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid medical problems. Do not self-diagnose the measurement results and start treatment by yourself. Always consult your doctor for evaluation of the results and treatment. Do not apply the cuff on an arm with an unhealed wound.
Parts Identification Button Button Button AC adapter plug DC Jack Air Connector Plug Button START Air Socket Display Air Hose Proper Fit Range Artery Position Mark Index Mark Arm Cuff Battery Compartment Battery Cover 1.5V Batteries (R6P, LR6 or AA) Display Average MEMORY...
Symbols Symbols that are printed on the device case Symbols Function / Meaning Standby and Turn the device on. Systolic blood pressure in mmHg Diastolic blood pressure in mmHg Pulse per minute Battery installation guide Direct current Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks.
Page 8
Symbols Symbols Function / Meaning Recommended Action The reading may yield an Appears during measurement when incorrect value. Apply the cuff correctly, and take the cuff is attached loosely another measurement. Detected rate of IHB/AFib in memory Number of detected IHB/AFibs in memory x100 [%] %IHB/AFib =...
Operation Mode 1. Normal Measurement Press the button. Blood pressure is measured and the data is START stored in memory. This device can store the last 60 measurements for each of the four user in memory. 2. Recalling the Data Press the button to recall the data in memory.
Page 10
4. Deleting Data Stored in Memory In standby, press both the buttons. The mark, battery indicator and user mark will appear. When you would like to delete the memory data of the currently displayed user, press and hold both the buttons until the illuminated mark starts blinking.
Using the Monitor Installing / Changing the Batteries Step 1 1. Remove the battery cover. Step 3 2. Remove the used batteries and Step 1 insert new batteries into the battery compartment as shown, taking Step 2 care that the polarities (+) and (-) are correct.
Using the Monitor Air socket Connecting the Air Hose r socket Insert the air connector plug into the air socket firmly. Air connector plug Connecting the AC Adapter Insert the AC adapter plug into the DC jack. Then, connect the AC adapter to an electrical outlet.
Using the Monitor Adjusting the Built-in Clock Adjust the clock prior to use. Press and hold 1. Press and hold the button until the year starts blinking. Year 2. Select the year using the button. Press the button to set the current year and move to month/day selection.
22 cm to 32 cm Adult Cuff Arm size: The circumference at the biceps. Note: The UA-767F-W is not designed for using a small cuff. Applying the Arm Cuff Do not roll up shirtsleeve tightly. 1. Wrap the cuff around the upper arm,...
Page 15
Using the Monitor Symbols that are printed on the cuff Symbols Function / Meaning Recommended Action Set the mark on the artery of the upper arm or Artery Position Mark in line with the ring finger on the inside of the arm. Index ▲...
Using the Monitor How to Take Accurate Measurements For the most accurate blood pressure measurement: Sit comfortably on a chair. Rest your arm on the table. Do not cross your legs. Keep your feet flat on the floor and straighten your back. Relax for about five to ten minutes before measurement.
Measurements Before measurement, refer to the section “Notes for Accurate Measurement” on the next page. Normal Measurement Press the button to select a user from 1 to 4. At heart level Press START Place the cuff on the arm (preferably the left arm). Sit quietly during measurement.
Measurements Measurement with the Desired Systolic Pressure The UA-767F-W is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. Use this method when re-inflation occurs repeatedly or when the results are not displayed even if the pressure decreases to 20 mmHg or less.
Recalling the Memory Data Note: This device stores the last 60 measurements for each of the four user in memory. 1. Press the button. Press The average of all measurements and the number of data are displayed. Average systolic (If no data, “0” is displayed. Press the Average diastolic button to turn the START...
Page 20
4. Press the button to display the memory display after changing the user number. User 1 5. Press the button to turn the START device off. After one minute of non-operation, the device will turn off automatically. User 2 User 3 User 4 English 19...
What Is The IHB/AFib Indicator? When the monitor detects an irregular rhythm during the measurements, the IHB/AFib indicator will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is 15% less or 15% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
Pressure Bar Indicator The indicator monitors the progress of pressure during measurement. Pressurizing Releasing air Inflation in progress Measurement in progress Inflation complete WHO Classification Indicator Each segment indicator Example: corresponds to the WHO blood pressure classification is described on the next page. WHO Classification Indicator Severe hypertension Moderate hypertension...
About Blood Pressure What is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).
described in this manual to get to know your normal blood pressure. Regular readings give a more comprehensive blood pressure history. Be sure to note the date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data. Troubleshooting Problem Possible Reason...
However it is generally recommended to have the device inspected every 2 years, to ensure proper functioning and accuracy. Please contact the authorized dealer in your area or A&D for maintenance. Technical Data Type UA-767F-W Measurement method Oscillometric measurement Measurement range Pressure: 0 - 299 mmHg...
Page 26
Applied part Cuff Type BF Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) AC adapter: 5 years (when used six times a day) Accessory AC adapter The adapter is to connect the device to a power source at home. Please contact your local A&D dealer for purchasing.
Need help?
Do you have a question about the UA-767F-W and is the answer not in the manual?
Questions and answers