Gas Conversions - Whirlpool 8523782 Installation Instructions Manual

Table of Contents

Advertisement

Check operation
E
(cont.)
If your oven has this type of electronic
control pads (with and without timer):
ON
CLOSE DOOR
BAKE
BROIL
8 8 8
START ?
PREHEAT
CLEAN
DOOR LOCKED
BAKE
CUSTOM
AUTO
TEMP
CLEAN
BROIL
A
ON
TIMER
BAKE
BROIL
8 8 8
START ?
HEAT
CLEAN
DOOR LOCKED
CLOCK
CUSTOM
AUTO
TEMP/
TEMP
TEMP
BAKE
TIME
CLEAN
BROIL
TIMER
B
1. Press the "CUSTOM BROIL" pad.
• "525" or "HI" will appear in the display.
• The "BROIL" indicator will light.
2. Press the "START/ENTER" pad.
• "HEAT"(console B only) and "ON" indicators
will light.
• If the burner fails to light due to air remaining
in the gas line, reset the oven control by
pressing the "OFF/CANCEL" pad and then
pressing the "CUSTOM BROIL" and
"START/ENTER" pads again to reactivate the
bake operation.

Gas conversions

Gas conversions (from Natural gas to L.P. gas; or
from L.P. gas to Natural gas) must be done by a
qualified installer.
WARNING
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning gas
supply valve back on.
Failure to follow these instructions can
result in explosion, fire or other injury.
Page 7
If your oven has this type of electronic
control pads:
888°
HEAT BAKE
CUSTOM
AUTO
BAKE
TEMP
TEMP
BROIL
CLEAN
C
START
OFF
ENTER
CANCEL
5 SEC
888
HEAT
BAKE
DELAY
BROIL
TIMED
CUSTOM
AUTO
TEMP
BAKE
TEMP
BROIL
CLEAN
D
1. Press the "CUSTOM BROIL" pad.
• "HI" will appear in the display.
START
OFF
• The "BROIL" indicator will light.
ENTER
CANCEL
5 SEC
2. Press the "START/ENTER" pad.
• "HEAT"and "ON" indicators will light.
• If the burner fails to light due to air remaining
in the gas line, reset the oven control by
pressing the "OFF/CANCEL" pad and then
pressing the "CUSTOM BROIL" and
"START/ENTER" pads again to reactivate the
bake operation.
23.
Check the broil burner for
proper flame. The flame should be 1/2"
long, with inner cone of bluish-green,
and outer mantle of dark blue, and
should be clean and soft in character. No
yellow tips, blowing or lifting of flame
should occur.
L.P . gas conversion
1.
Complete installation sections A-C (Pages
4-5) before converting cooktop to L.P. gas. Check
that main gas supply line has been shut off and
the power supply cord is disconnected.
88:88
ON
F
BROIL
CLEAN TIMER
TIMER
CANCEL
SET
START
OFF
CLOCK
LIGHT
HR
MIN
ENTER
CANCEL
TIMER
OFF
5 SEC
88:88
C
TIMER
TIMER
CLOCK
LIGHT
F
SET
OFF
TIMER
STOP
ON
LOCKED
CLEAN
START?
COOK
TIME
DELAY
START
OFF
COOK
STOP
START
HR
MIN
TIME
TIME
ENTER
CANCEL
TIME
5 SEC
CANCEL
air shutter
and lock screw
If flame needs to be adjusted:
Loosen the lock screw on the air shutter
located at the rear of the broil burner.
Adjust the air shutter as needed.
Tighten lock screw.
24.
Turn the oven control knob to "OFF"
or press the "OFF/CANCEL" pad.
You have just finished installing
your new range. To get the most
efficient use from your range, read your
Use & Care Guide.
Keep Installation Instructions and Guide
close to range for easy reference.
The instructions will make installing the
range in another home as easy as the
first installation.
pressure
regulator
plastic
cover
Natural
pressure
regulator
plastic
cover
L.P.
cap
washer
Nat. gas
DO NOT REMOVE THE PRESSURE REGULATOR.
2.
Pressure regulator: Remove storage
drawer and locate pressure regulator at back of
range. Remove plastic cover. Turn cap marked
"N" on front of pressure regulator
counterclockwise with a wrench to remove. Do
Not disturb or remove the spring beneath the
cap. Turn the cap over and reinstall cap on
regulator so that the letters "L.P." are visible.
Replace plastic cover over cap.
L.P. gas

Advertisement

Table of Contents
loading

Table of Contents