Mounting........2 Disassembly ....... 3 Connections ....... 2 Description The JSK-120 is a single axis joystick designed for use with our Pro-160 / 360 series controllers. It has a hall effect sensor for long life. It has a removable detent to identify the center off position.
Page 2
Mounting The JSK-120 requires a 47mm diameter hole in the mounting panel. There is no limitation on the panel thickness. Connections The JSK-120 uses the Vishay 981HE sensor and the wiring colours are somewhat counter intuitive…. Green = +5V ...
Page 3
1. Insert a 1.5 mm allen key through the collar hole into the drum grub screw. 2. Undo the M4 handle retaining screw. 3. Place the JSK-120 handle side down and lift off the collar / drum / sensor assembly. Take care to retain the ball bearing, spring and serrated washer.