Advertisement

Quick Links

Installation Guide
Model: H60-EC
Covered by the following United States and International Patents:
D631148S, 138172, 001790452-001, 338608 and other patents pending
1650 38
St, Suite 201W
Boulder, CO 80301
PHONE: 303-557-1852
zoofans.com
th
©2019 ZOO FANS INC. ALL RIGHTS RESERVED
REV 09062019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H60-EC and is the answer not in the manual?

Questions and answers

Summary of Contents for Zoo Fans H60-EC

  • Page 1 Installation Guide Model: H60-EC Covered by the following United States and International Patents: D631148S, 138172, 001790452-001, 338608 and other patents pending 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 2 WARNING: To prevent electrical shock and/or injury disconnect fan from power source before you move or service the fan. Not Suitable for use with solid-state speed controls. WARNING: To reduce the risk of fire, electric shock, and injury to persons, ZOO Fans must be installed only with controllers supplied by ZOO Fans. Other parts cannot be substituted.
  • Page 3 AVERTISSEMENT : Restez vigilent, faites attention à ce que vous faites, et faites preuve de bon sens lors de l’installation de ventilateurs ZOO Fans. N’installez pas de ventilateurs si vous êtes fatigué ou sous l’influence de drogues, d’alcool ou de médicaments.
  • Page 4: Table Of Contents

    OPTION 2 - Wiring 10k Ohm Potentiometer ........................10 OPTION 3 - Wiring 0 – 10VDC Analog Signal ........................10 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 5: Pre-Installation

    PRE-INSTALLATION The safe installation and operation of equipment supplied by ZOO Fans is the responsibility of the system designer, installer, maintainer, and operator (collectively, the “User”). The need for protective safety accessories to meet company standards, applicable codes, and the requirements of the Occupational Safety and Health Act (“OSHA”) must be determined by the User since safety requirements may vary depending on the location and application of the equipment.
  • Page 6: Zoo Fans Specifications

    You may also contact your ZOO Fans’ representative or ZOO Fans directly if you require assistance. Remember, the number of ZOO Fans required for the job, as well as where they are hung, will depend on a number of variables, some of which are: •...
  • Page 7: Installation

    The fan intake must be 12” from any obstruction. ZOO Fans are designed to be hung vertically or at an angle. For vertical installations, proceed to STEP 1 below. To install the ZOO Fan at an angle, additional hardware is required. Please contact ZOO Fans or your ZOO Fans’ representative.
  • Page 8: Step 2: Fasten Stabilization Tether

    2. Insert 1/4” Hex Head bolt through the hole located at 45° on either side of the handle 3. Securely tighten 1/4” Nylock Nut Illustration 2 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 9: Step 3: Secure The Gripples

    2. Loop cable over Truss, I-Beam, or support beam 3. Insert end of cable into Gripple 4. Adjust to desired height Illustration 3 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 10 4. Adjust cable so there is no slack 5. Excess cable should be neatly rolled up and taped or cut for a clean installation Illustration 4 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 11 Illustration 5 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 12 Illustration 6 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 13: Wiring The Line Voltage

    To control on/off and speed of the fan, use the low-voltage control. Refer to WIRING THE CONTROL SIGNAL. The H60-EC fan is available with a pre-wired 6’ cord and 3-pronged plug option. If your fan will be hard wired and does not...
  • Page 14: Wiring The Control Signal

    0 – 10 Volt DC analog signal PWM signal (contact Zoo Fans for wiring instructions) WARNING: Never apply line voltage to the control signals OPTION 1 – Wiring AVS-EC-Auto Please refer to ZOO Fans AVS-EC-Auto installation guide for wiring OPTION 2 - Wiring 10k Ohm Potentiometer Please refer to ZOO Fans VSPOT-10K Installation Guide OPTION 3 - Wiring 0 – 10VDC Analog Signal 0-10VDC Contact Zoo Fans for other control options.
  • Page 15 1650 38 St, Suite 201W Boulder, CO 80301 PHONE: 303-557-1852 zoofans.com ©2019 ZOO FANS INC. ALL RIGHTS RESERVED REV 09062019...
  • Page 16 ZOO Fans 1650 38 St. Suite 201W Boulder, CO 80301 Phone: 303.557.1852 Fax: 720.596.5192 info@zoofans.com zoofans.com...

Table of Contents