Advertisement

Quick Links

INSTALLATION, OPERATING AND
ELECTRONIC WATER FILTER
FEATURING THE 2002F VALVE
COLOR, TASTE, ODOR
7-LETCT-1
7-LETCT-2
7-LETCT-3
IRON FILTER
7-LETIM-1
7-LETIM-2
7-LETIM-3
Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you
many years of trouble free service. For servicing and future inspection purposes, please file this
booklet with your important documents.
In the event that you need assistance for servicing your water filter, please first contact the
professional contractor who installed the system.
SERVICE MANUAL
TIME CLOCK MODEL
7-LETCTG-1
7-LETCTG-2
7-LETCTG-3
7-LETIMG-1
7-LETIMG-2
7-LETIMG-3
PAGE 1
SEDIMENT/TURBIDITY
7-LETST-1
7-LETST-2
7-LETST-3
ACID NEUTRALIZERS
7-LETDAN-1
7-LETDAN-1.5
7-LETDAN-2
7-LETDAN-3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7-LETCT-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lancaster 7-LETCT-1

  • Page 1 7-LETIMG-3 7-LETDAN-2 7-LETDAN-3 Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you many years of trouble free service. For servicing and future inspection purposes, please file this booklet with your important documents. In the event that you need assistance for servicing your water filter, please first contact the professional contractor who installed the system.
  • Page 2: Operating Parameters

    A8007 BIRM - (1) 7-LETIM-2 FG1348VT, 13 X 48 A8007 BIRM - (2) 7-LETIM-3 FG1465VT, 14 X 65 A8007 BIRM - (3) 7-LETCT-1 FG1044VT,10 X 44 A8009 CARBON - (1) 7-LETCT-2 FG1348VT, 13 X 48 A8009 CARBON - (2) 7-LETCT-3...
  • Page 3: Installation

    INSTALLATION Place filter in desired location close to water supply inlet, after pressure tank, and near a source for waste water, (utility sink, floor PRESSURE BYPASS SHOULD TANK drain or sewer line). A 115/120V, 60Hz uninterrupted outlet is required. BE PIPED IN IF OPTIONAL BYPASS VALVE IS NOT USED Keep filter far enough away from walls and other obstructions to allow...
  • Page 4: Set Time Of Day

    PROGRAMMING THE CONTROL VALVE: Note: A quick-reference card is stored inside the front cover of the control valve. To access this card, slightly pull tabs on side of cover outward and pull cover forward. Plug the electrical cord into a 115 Volt receptacle.
  • Page 5: Drive Assembly

    ADDITIONAL PROGRAMMING INFORMATION AVAILABLE FROM LANCASTER WATER TREATMENT UPON REQUEST. INCLUDES: 7-DAY OPTION, REGENERATION CYCLES, TIMES AND 50 Hz. SERVICE INSTRUCTIONS ACID NEUTRALIZERS, (7-LETDAN-): Mineral used: Calcite. Calcite will dissolve in proportion to the amount of acid in the raw water.
  • Page 6: Drive Cap Assembly, Main Piston And Regenerant Piston

    DRIVE ASSEMBLY CONTINUED To inspect drive gears, the drive gear cover needs to be removed. The drive gear is held in place on the drive bracket by three clips. The largest of the three clips is always oriented to the bottom of the drive bracket. Before trying to remove the drive gear cover, the drive bracket must be removed from the drive back plate.
  • Page 7: Spacer Stack Assembly

    SPACER STACK ASSEMBLY: To access the spacer stack assembly remove the drive assembly, drive cap assembly and piston. The spacer stack as- sembly can be removed easily without tools by using your thumb and forefinger. Inspect the black o-rings and red or clear lip seals for wear or damage.
  • Page 8: Bypass Valve

    BYPASS VALVE: The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps. Before working on the rotor, make sure the system is depressurized. Turn the red arrow shaped handles toward the center of the bypass valve and back to the arrow direction several times to ensure rotor is turning freely.
  • Page 9 PARTS                 V3007 1” PVC Male NPT Elbow Assembly  Standard Item No. Quantity Part No. Description  V3007-02 1” Brass V3151 Nut 1” Quick Connect ...
  • Page 10 V3186EU WS1 AC ADAPTER 220-240V-12V EU Not Shown V3186UK WS1 AC ADAPTER 220-240V-12V UK V3186-01 WS1 AC ADAPTER CORD ONLY * Drawing number parts 2 through 6 may be purchased as a complete assembly, part V3002. FRONT COVER AND DRIVE ASSEMBLY When replacing the battery, align Correct positives and push down to fully seat.
  • Page 11: Drain Line

    WS1 & WS1.25 Drawings & Service Manual Page Drain Line – 3/4” Drawing No. Order No. Description Quantity METER PLUG H4615 Elbow Locking Clip PKP10TS8-BULK Polytube insert 5/8 Option Item No. Quantity Part No. Description V3192 WS1 Nut ¾ Drain Elbow Option V3158-01 WS1 Drain Elbow ¾...
  • Page 12: Troubleshooting

    ▲ and ▼ b. Set-up error b. Check control valve set-up buttons are depressed. procedure A DIVISION OF C-B TOOL CO. 1340 MANHEIM PIKE ● LANCASTER PA 17601-3196 ● TEL:717-397-3521 ● FAX: 717-392-0266 4/15 PAGE 12 www.lancasterwatertreatment.com ● E-mail: info@lancasterpump.com...

Table of Contents