Download Print this page
Hide thumbs Also See for Irrigreen2:

Advertisement

Quick Links

Irrigreen2 Installation Manual
Irrigreen®
Digital Sprinklers
Wi-Fi Cloud Connected Controller
Waterproof Plug-n-Play Cabling
16 Digital Zones
12 Valve Zones
Smart Irrigation Zone
Installation Video
Design Video - IOS
1.1.1
0921
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Irrigreen2 and is the answer not in the manual?

Questions and answers

Summary of Contents for IrriGreen Irrigreen2

  • Page 1 Irrigreen2 Installation Manual Irrigreen® Digital Sprinklers Wi-Fi Cloud Connected Controller Waterproof Plug-n-Play Cabling 16 Digital Zones 12 Valve Zones Smart Irrigation Zone Installation Video Design Video - IOS 1.1.1 0921...
  • Page 2 Irrigreen Products Controller Cable (50 ft w/end plug) Sprinkler Cable (50ft) Irrigreen2 Wi-Fi / Cloud Controller 16/12: 16 Digital Zones, 12 Valve Zones 32/24: 32 Digital Zones, 24 Valve Zones Digital Sprinkler (1 per zone, ~2000 sq. ft.) Cable Tee (w/end plug) 1”...
  • Page 3 Other Items Needed (Not supplied by Irrigreen) 1” Elbows and connectors PVC or poly 1“ Mainline PVC or poly 6” valve boxes 1” Tees with 1” female pipe thread *One for each Digital Zone PVC or poly Protects cable connections...
  • Page 4 Irrigreen System Requirements Good flow, Constant pressure, Clean Water • 8 gpm Lower flow = shorter throw) • Important to check flow, some homes have 3/4” pipe inside the home, which restricts flow to the irrigation system, lessening throw • 40 - 80 psi (Any constant pressure between 40 - 80 psi) •...
  • Page 5 System Design (1 of 2) One Head per Zone Place Head to Reach Farthest Corner, 25-35 Feet Exact placement NOTE: The zone not critical as you start up point can program the (Position 1) head to the shape must be set at of the zone least 10 feet so the head has...
  • Page 6 System Design (2 of 2) One Head per Zone Place head 5 feet or more from the nearest edge* *For narrow zones less than 10’ wide, place head along edge and program in a ~180 degree pattern...
  • Page 7 30’ 60 psi 5’ 70 psi 32.5’ 70 psi 5’ 80 psi 35’ 80 psi 5’ Total Area At 60 psi, one Irrigreen head will evenly water up to ~2000 sq.ft. Any line-of-sight shape within a 60 foot diameter circle...
  • Page 8 6” Valve box next to each head for cable connectors and extra cable...
  • Page 9 Download the IG2 mobile app (raindrop logo) Follow IOS App Instructions. Scan barcode with App For Android, connect to Irrigreen Wi-Fi network and enter system password (Calibration and Auto Water require IOS App) Controller broadcasts an Irrigreen Wi-Fi signal Irrigreen2...
  • Page 10: System Wiring

    System Wiring 2 AAA...
  • Page 11 Digital Sprinklers are Connected with Cables Daisy-chain up to eight Digital Sprinklers per run (#1-8 and #9-16) Digital Zones 1-8 Red Controller cable lead to “IG Digital 1-8” White Controller cable lead to “Common” Digital Zones 1-8 Red Controller cable lead to “IG Digital 9-16” White Controller cable lead to “Common”...
  • Page 12 Irrigreen Connector Orientation Similar to electrical extension cords* Larger “female” connectors always point away from the Controller All of the smaller “male” connectors point back to the Controller *Male points back to the outlet, female points away from the outlet...
  • Page 13 Eight Sprinklers per Controller Cable Connect sprinklers with Sprinkler Cables and Cable Tees Digital Sprinklers #1-8 will run on one cable: Wire Controller Cable to “iG 1-8” and “Common” Locate Sprinklers #1-8 in the order you want them to run Digital Sprinklers #9-16 will only run on a second Controller cable: Wire second Controller Cable to “iG 9-16”...
  • Page 14 Sprinklers are Pre-numbered for each Zone Locate each sprinkler in the numerical order you want them to run* Before burying heads: Plug all heads together and confirm they run *Head #1 runs first Digital Sprinklers have Zone Numbers Head #2 runs second 1-8, 9-16 assigned at the factory Head #3 runs third Etc.
  • Page 15 DO use supplied Flex-Pipe for plumbing heads • DON’T cut and splice IrriGreen Cables • DON’T pull IrriGreen Cables with a vibra plow … DO pull 1” conduit for the cables if pulling pipe • DON’T use Teflon tape inside of Irrigreen heads •...
  • Page 16 Install on all Cable connections...
  • Page 17 Protect Cable Connections All connections must be protected by a small valve box Install next to Digital head below turf Install box below turf...
  • Page 18 Use of Flex Pipe required for warranty* Bury to here Top of head slightly above grade Hand tighten head onto the elbow until it bottoms out against the o-ring inside the head Do not use teflon tape on the Teflon tape use recommended elbow fitting* on the 1”...
  • Page 19 Suggested Pre-assembly The last head on the water lines (all directions) should be taken off of Flex-Pipe when flushing dirt and debris from the lines Helpful Hint: When flushing the lines, disconnect the head and point Flex-Pipe out of hole to keep the hole from filling with water...
  • Page 20 Digital Sprinkler Head Depth Dig 15” hole Position head so the top of the Digital Sprinkler cap is about ½” above grade...
  • Page 21 Flush all lines. Twice. Before, and after, installing heads* • 1. Before installing any heads, flush lines to remove all dirt, sand, debris* 2. After all heads are installed, run the last Digital Sprinkler(s) on the end of Rocks, all pipe runs for several minutes to sand, etc remove all air from the system.
  • Page 22 Irrigreen2 Controller Terminals Rain/Soil Sensor 1 Flow Sensor 1 Digital Sprinklers 1-8 Digital Sprinklers 9-16 Master Valve Valve Zones 1-12...
  • Page 24 Controller runs hybrid systems with Digital Sprinklers, Drip and Spray Zones...
  • Page 25 Master Valve Recommended for all Systems Master Valve Wiring Irrigreen software relieves mainline pressure by keeping the last head valve open for a few seconds after the Master Valve closes...
  • Page 27 Irrigreen2 Controller Indicator Lights Blue LED Red LED Flashing: Green LED is ON, blinks off Flashing: System Error briefly: System connected to the System is Home Wi-Fi network watering Green LED is OFF, blinks on briefly: System is not connected...
  • Page 28 Irrigreen2 Controller Buttons Green RESET Button Blue MODE Button Red SELECT Button Reset System: Run All Zones : Stop all watering: Press 1 second Press 3 Seconds to Press 1 Second run all zones Skip a Zone: Press for 1 Second...
  • Page 29 System Reset: System Reset: Press Green button 1 second. Will re-connect to Home Wi-Fi in 10 seconds Direct Connect to Controller: Press Red button 6 seconds, the Irrigreen Wi-Fi Network will appear. Log in with the password. Press Red button six...
  • Page 30 Shortened Stream Distances? Streams Not Evenly Spaced? Calibration failing? Remove cap as shown and clean the filter Hand tighten cap back onto riser (NOTE: filter mesh points down) For reassembly, make sure filter markings line up with nozzle opening...
  • Page 31 Removing Cap for Servicing Nozzle and Filter Lift riser up Grasp riser and remove cap by hand Tighten torx screw on cap after reassembly...
  • Page 32 Optional Ultrasonic Flow Sensor Installation 24” PVC before and 12” after the flow sensor* Install Ultrasonic Flow Sensors at 45 NOTE: IrriGreen now supplies pre-cut PVC pipe for flow sensor installation, use two sections upstream, one section downstream 24” 1” PVC 12”...
  • Page 33 Optional Flow Sensor Installation Waterproof “DBY” connections supplied Install Flow Sensor and Splices in Valve Box Ultrasonic Use DBYs as shown Flow sensors must Picture shows an be installed at 45 Impeller flow sensor in vertical orientation Use the supplied 3M® DBY “grease cap with wire nut” connectors Push wire nut all the way into gel cap, ensure wires and wire nut are totally sealed by gel NOTE: 24”...
  • Page 34 Small valve box (6”-10”) conductor wire connectors For protecting optional flow sensor Connects optional flow sensor Connects flow sensor leads to the Irrigreen2 Controller to the flow sensor wire 3M® DBY/R, Orbit® 57002 or similar Irrigreen supplies two with each flow sensor...
  • Page 35 Optional Flow Sensor Wiring to Controller Red Flow Sensor lead to “Sen1” Black lead to “Common” Black Flow Sensor lead Red Flow Sensor lead to to“Common” Controller Terminal“Sen1”...
  • Page 36 (2) this device must accept any interference received, including interference that may cause undesired operation. Per FCC 15.21: The user and installer of the IrriGreen Genius Irrigation System shall not make any modifications to the system not expressly approved by IrriGreen. Unauthorized modifications...