GsmAlarm-500 (V1.15)
GSM Alarm and Remote Control System
FEATURES
6 inputs.
Up to 15 protection zones.
3 programmable low current outputs + 1 high current relay output.
5 users are notified.
20 programmable keypad access codes or iButton keys.
Possibility to transfer data to alarm monitoring station via GPRS channel by SIA DC-09 IP
protocol. AES128 encryption.
Possibility to connect to SmartCloud server. Monitoring and control of the system can be
performed from any computer or smart phone using a standard web browser.
Possibility to send information to alarm monitoring station using the Contact ID protocol
through GSM voice call.
Remote control using mobile phone keypad (through DTMF tones).
GSM JAMMING detection.
24 hour timer.
Two partial protection modes (STAY and SLEEP).
Possibility to divide the system into two independent partitions.
Possibility to connect up to 6 temperature sensors for temperature measurement.
Possibility to connect up to 4 keypads.
Info-carrying SMS showing state of each sensor, power supply voltage, GSM signal
strength.
Programming and firmware upgrade via USB connection.
Remote programming over GPRS.
Integrated quad-band GSM module.
Wide operating temperature range: -35 ... +65ºC.
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GsmAlarm-500 and is the answer not in the manual?

Questions and answers

Summary of Contents for eltech GsmAlarm-500

  • Page 1 GsmAlarm-500 (V1.15) GSM Alarm and Remote Control System FEATURES • 6 inputs. • Up to 15 protection zones. • 3 programmable low current outputs + 1 high current relay output. • 5 users are notified. • 20 programmable keypad access codes or iButton keys.
  • Page 2: Table Of Contents

    5.3.2.7. Parameter “L”: SMS Structure and SMS Password Functionality ......25 5.3.2.8. Parameter “P”: Splitting of the system into 2 partitions. 24 hour tamper supervision ..................25 5.3.3. Programming Partition Names..................25 5.3.4. Setting System Clock ...................... 26 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 3 7.3. Modes Of Data Transfer To the Central Monitoring Station ..........44 7.4. CONTACT ID Protocol Codes ....................45 8. System Control Using the Keypad ..................... 46 8.1. Keypad Keys and LED Indicator Functionality ..............46 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 4 13. GSM Jamming Detection ......................52 14. System Control Using DTMF and SMS Commands .............. 53 SmartCloud Server ....................... 56 15.1 Settings and Activation ......................56 16. Warranty ........................... 57 17. Technical Characteristics ..................58 18. Mounting Holes ........................59 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 5: General Information

    Open circuit breaker must have a gap between connections of more than 3mm and the disconnection current 5A. System GsmAlarm-500 is a device mounted in limited access areas. Any system repairs must be done only by qualified, safety aware personnel. There are no parts you can change at place in the device.
  • Page 6: Package Content

    The system installation or maintenance must not be done during stormy conditions. Remote control and monitoring device GsmAlarm-500 has built-in radio transmitter operating on GSM900 and GSM1800 networks. Do not use the device where it can cause interferences and danger.
  • Page 7: Introduction

    Up to 4 Paradox K636, K10V/H (MG10LEDV/H), K32 (MG32LED), K32LCD (MG32LCD), TM50 keypads can be connected to GsmAlarm-500. By using the keypad users can arm or disarm the system and configure system parameters. Following keypad LED indicators you can determine protected unit state, system mode etc.
  • Page 8: Connectors And Led Indicators

    KEYPAD CONNECTION TERMINALS “GR” and “YL” Use GR, YL, GND and AUX terminals to connect PARADOX K636, K10V/H (MG10LEDV/H), K32 (MG32LED) or K32LCD (MG32LCD) keypad. These terminals can also be used for connection of the iButton key reader. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 9: Auxiliary Power Terminal Aux

    2.6. “AC” POWER TERMINALS Use a 16-24 VAC transformer with a minimum 40 VA rating to supply AC power to the GsmAlarm-500. 2.7. “BATT” CONNECTOR Use this connector to connect the backup battery. Max capacity of the backup battery is 1,2 Ah.
  • Page 10: Led Indicators

    Blinking with low frequency (once in System is armed. 2-3 sec.). Blinking more frequently than once a System is in alarm state. second. Blinking very rapidly for 2-3 sec. SMS instruction or DTMF command receipt confirmation. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 11: Installation

    Use double isolated cable 3x0,75 mm for 230V power supply. Circuit breaker or other surge protection device should be installed in the 230V power line. Antenna is fixed on the top of outer side of metal housing. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 12 A SIM card needed for GsmAlarm-500 operating, you may acquire it from any GSM service provider. Before inserting SIM card into GsmAlarm-500 SIM card slot set PIN code request off. It can be performed simply inserting SIM card into any standard mobile phone and following certain phone user manual instructions.
  • Page 13: Wiring Diagrams

    YEL. ~1.2 A DS9092LED Siren 2-wire smoke detector iButton key EA318-2 reader I-Button 4.7k GREY Buzzer Power supply BPT-23CXW-1 for motion or fire detectors Additional Switch ON/OFF relay (if iButton key is not used) _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 14: Wiring Diagram When The Device Operates In The Gate Control Mode

    In this case, individual operated outputs could be assigned to different telephone numbers (see Ch 5.2.1). The system is controlled by a DALLAS key when necessary. Programming of gate control mode of the device is described in Chapter 5.3.2.2 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 15: Ways To Connect Alarm Zones

    A1Y-A6Y: zone operating modes, parameter “A” (see Chapter 5.3.1.1). GsmAlarm-500 has 6 inputs Z1...Z6, corresponding to the zone numbers Z01...Z06. If 6 zones are sufficient for protection of the object, the wiring diagrams 1, 2, 3 or 4 may be deployed.
  • Page 16: Connection Of Temperature Sensors

    0.5 mm². Shield is connected to ground wire only in one end, close to GsmAlarm-500 board. Use 2 pins terminal block with a fixing hole for temperature sensor fastening. Parameter “A” must be changed in order to activate temperature measurement mode. (see Ch.
  • Page 17: Programming

    If only one user exists, he must be programmed under ALRNR1. GsmAlarm-500 will send SMS messages to this specific user in case of main power supply loss or if an unknown number calls the system. If armed mode is turned on or off with the single touch of the keypad or by turning the switch ON/OFF (if the keypad is not used) control dials and SMS messages are also directed to the first user.
  • Page 18: Programming With Standard Mobile Phone

    (E.g. +370...). If GsmAlarm-500 is used for gate control, number of extra user numbers can be as large as fits into the SIM card (up to 250). Any name can be assigned to extra user. Also the user number can be assigned to control only the selected output.
  • Page 19 A L R N R 1 : + 3 7 0 6 1 2 3 4 5 6 7 8 9 Receipt and decrypting of the SMS by GsmAlarm-500 is confirmed by blink of indicator MODE. The phone, which has sent the programming SMS, immediately receives a confirming SMS with programmed numbers.
  • Page 20: Programming System Parameters With Sms

    SMS with corrected parameters back to GsmAlarm-500. 5.3.1. PROGRAMMING ZONES In order to receive SMS with zone Z1 - Z15 parameters, send GsmAlarm-500 the following SMS: A A A A A A A A Z P A R A M SMS can be sent from any GSM phone, not necessarily the user’s.
  • Page 21 Possible values: -40 ºC ... 120 ºC. Zone1, Zone2, Zone3, Zone4 – zone names, which are seen in the SMS after alarm triggering. User can change the name of zone under his own discretion. Maximum number of name characters: 16. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 22: Parameter "A": Input Triggering Conditions

    3) 24-hour zone. Violation of the protected zone activates alarm in armed or disarmed mode. Siren operates continuously, the delay time is ignored. 4) Fire Zone working in 24 hour mode, the siren is intermittent. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 23: Parameter "M": System State After Input Triggering

    All (ALRNR1-ALRNR5), but not the alarm monitoring station. Important: alarm monitoring station is informed when data transfer to monitoring station is turned on (see Ch. 7.3), number X is higher than 0 and number Y isn’t equal to 9. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 24: Stay And Sleep. Tamper Recognition

    5.3.2. PROGRAMMING OUTPUTS C1-C4 (K1, K2) AND COMMON SYSTEM PARAMETERS “E”, “F”, “G”, “H”, “J”, “K”, “L”, “P”, “T” In order to receive SMS with output and common system parameters, send GsmAlarm-500 the following SMS: A A A A A A A A C P A R A M Receiving the message is confirmed by blinking of indicator “MODE”, SMS with current system...
  • Page 25 P00 - splitting of the system into partitioning and 24 hour tamper supervision (see Ch. 5.3.2.8). T20 - entry delay time. Possible values: 00 – 99 seconds. After correction of the parameters SMS message is sent back to GsmAlarm-500. _________________________________________________________________________________ GsmAlarm-500 Software ver.
  • Page 26: Output C1-C4 (K1, K2) Operating Mode

    1 and 2 for 3 sec or by the command “Logical Key 1”. ** The output is deactivated by simultaneously pressing and holding the keypad buttons 2 and 3 for 3 sec or by the command “Logical Key 4”. ** _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 27: Outputs C1-C4 (K1, K2): Inverted Mode And Operating Time Units

    Connect the system after the wiring diagram presented in Chapter 4.2.3. The message AAAAAAAA CPARAM is sent to GsmAlarm-500 to instruct the device to operate in the gate control mode (see Ch 5.3.2.). When output K1 K2 (see Ch. 4.2.3) is used for control of the gate, output parameter M02 in the message received from the device is changed, for example, to M05 and send the message back with the modified values.
  • Page 28: Parameter "E": The Way User Is Informed About Arming/Disarming

    Possible delayed time values: G01-G99 (in minutes). After recovery of the main power supply, report will be send after 1 minute period of time. This time cannot be programmed. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 29: Parameter "L": Sms Structure And Sms Password Functionality

    R P A R A M GsmAlarm-500 sends SMS message with available names of the partitions: AAAAAAAA R1: PARTITION1, R2: PARTITION2, After correction of the names, SMS message is sent back to GsmAlarm-500. Maximum number of the name’s characters is 16. _________________________________________________________________________________ GsmAlarm-500 Software ver.
  • Page 30: Setting System Clock

    -timer instruction, defining which function should be performed in programmed time. Please read detailed description of timer instructions in Ch. 5.3.5.1. 00-00 - timer activation time. Renewed SMS message has to be sent to GsmAlarm-500. User receives SMS message with newly programmed parameters after. _________________________________________________________________________________ GsmAlarm-500...
  • Page 31: Timer Instructions

    For the system to activate PGM output C2 on 12:30, deactivate on 13:00 and to send SMS message, informing about the state of outputs on 13:01, following SMS has to be sent to GsmAlarm-500: A A A A A A A A...
  • Page 32: Programming The Description Of Input Zone State

    GsmAlarm-500 sends 3 messages with user names to the user : AAAAAAAA U01:User1, U02:User2, U03:User3, U04:User4, U05:User5, U06:User6, U07:User7, A corrected SMS message is sent to GsmAlarm-500. The user receives a confirmation SMS message with the user names. The maximal length of a user name: 16 characters.
  • Page 33: Programming The System Using The Keypad

    Output operating mode. M (C01-C04) Output operating time units: seconds / minutes V ( C01-C04) 331-345 Pulse counting mode. I (Z01-Z15) 401-420 Timer events. STIMER Time and date programming. SCLOCK * parameters if programming by SMS message. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 34: Programming Access Codes

    14 User Access Code ALRNR4 15 User Access Code ALRNR5 15 User Access Code ALRNR1 17 User Access Code ALRNR2 18 User Access Code ALRNR3 19 User Access Code ALRNR4 20 User Access Code ALRNR5 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 35: User Access Code Functionality

    The closing code transmission takes place after the exit delay time. Therefore, if the system is armed and disarmed before the expiry of the exit time, no transmission will take place. Possible values: 00 – 99 seconds. Address Parameter Exit delay time Manufacturer-programmed exit delay time: 20 seconds. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 36: Parameter "T": Entry Delay Time Or Triggering Temperature

    Zone Z12 „M“ parameter Zone Z5 „M“ parameter Zone Z13 „M“ parameter Zone Z6 „M“ parameter Zone Z14 „M“ parameter Zone Z7 „M“ parameter Zone Z15 „M“ parameter Zone Z8 „M“ parameter Manufacturer-programmed values for all zones: 70. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 37: Tamper Recognition (Parameter P)

    „I“ parameter of zone Z13 „I“ parameter of zone Z6 „I“ parameter of zone Z14 „I“ parameter of zone Z7 „I“ parameter of zone Z15 „I“ parameter of zone Z8 The factory default values for all zones: 02. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 38: Zone Response Time

    Possible operating modes are described in detail in Chapter 5.3.2.1. Address Parameter Operating mode of output C1. Operating mode of output C2. Operating mode of output C3. Operating mode of output C4. Manufacturer-programmed output modes: C1:01, C2:05, C3:31, C4:06. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 39: Outputs C1-C4 (K1, K2): Inverted Mode And Operating Time Units

    OF CALLS TO USER Parameter „F“ defines system response to incoming calls and number of calls to user in alarm state. It is described in detail in Chapter 5.3.2.5. Address Parameter System parameter „F“. Manufacturer-programmed value: 31. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 40: Parameter "G": Delay Time Of Report Sms About The Power Supply Failure

    This parameter is described in Chapter 5.3.2.7 in more detail. Address Parameter System parameter „L“. Manufacturer-programmed value: 32. 5.7.19. PARAMETER “P”: DIVIDING INTO PARTITIONS. 24 HOUR TAMPER SUPERVISION. The parameter is comprehensively described in Ch. 5.3.2.8 Address Parameter System parameter „P“. Manufacturer-programmed value: 00. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 41: Access Code Length (4 Or 6 Digits)

    3. Keypad zone is deleted by pressing [CLEAR] and [ENTER] keys. Important: after assigning zone to the keypad, the corresponding input zone won’t be operating on the GsmAlarm-500 board. 5.7.23. SETTING SYSTEM CLOCK To set system clock and date: •...
  • Page 42: Programming 24 Hour Timer

    Manufacturer-programmed Contact ID user account number: 0000. The six digit account number mode corresponds only to the first four digits. The last two digits are ignoring. When programming, you can enter two zeros at the end. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 43: Temperature Correction

    The GSM alarm configuration tool is downloadable from the website of the manufacturer: www.eltech.lt. Without a computer, only programming of new keys is possible. Deletion and setup of programmed keys is impossible.
  • Page 44: Programming And Diagnostics Over The Internet

    A A A A A A A A A P N A P N The massage returned to the user by GsmAlarm-500 contains the access point name, the login name and the login password: AAAAAAAA APN:internet.tele2.lt, APLOG:wap, APPASS:wap, Adjust the access point name, the login name and the login password as required. In Lithuanian networks OMNITEL and BITE GSM, all fields may be blank (comma after colon).
  • Page 45 30 seconds. The computer IP address that was included in the SMS message from the user is automatically saved in the GsmAlarm-500 memory. Later, the command CONNECT is sufficient to make the GSM module to connect to the same IP address:...
  • Page 46: Resetting System Settings To Factory Defaults

    Common system parameters Password [273] [274] [133] [233] [238] [ - ] [237] [236] [100] AAAAAAAA Administrator access code: 0000 (000000) First user access code: 1234 (123456) [Addr.] - parameter address when programming with the keypad. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 47: Data Transfer To Alarm Monitoring Station

    GPRS channel, and if fails, are attempted to make a call and transmit data by the audio channel. GsmAlarm-500 transfers data about violation and restoring of alarm zone, arming and disarming, power supply fault, malfunction of the backup battery, malfunction of the fire zone. Test messages can be sent on certain time.
  • Page 48: Audio Channel Settings

    P R O G R A M M I N G If data encryption is used, the encryption key can be entered using GAprog program. GsmAlarm-500 supports AES128 encryption algorithm. GPRS access point settings can be received at GSM service operator. In most cases, all access point settings can be left blank.
  • Page 49: Contact Id Protocol Codes

    6 (full transfer via audio channel). * In order that GsmAlarm-500 would send test message to the alarm monitoring station once per day, it is necessary to set system clock (see Ch. 5.3.4) and program 24 hour timer (see Ch. 5.3.5).
  • Page 50: System Control Using The Keypad

    * System‘s clock should be set only system timer function is used. System clock deregulates in case main power supply and backup battery are disconnected. System clock setting with SMS message directions described in Chapter 5.3.4. System clock setting with keypad described in Chapter 5.7.23. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 51: Mem] Key - Alarm Memory Display

    This indicator is not alight when there is no 230 VAC power supply voltage and system is powered by backup battery only. 8.1.8. “StayD” (STATUS) INDICATOR Indicator is on when all zones are closed and system is ready to be armed. 8.1.9. “OFF” INDICATOR Indicator is on if the system is disarmed. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 52: Arm", "Sleep" And "Stay" Indicators

    Enter a 4-digit or 6-digit user access code. Stay and Sleep arming can also be activated using 24-hour timer or One-Touch arming. Press and hold the [STAY] key or the [SLEEP] for 3 seconds to arm the system. _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 53: Disarming & Deactivating An Alarm

    8.7. PROGRAMMABLE OUTPUT CONTROL The programmable output (PGM) on the GsmAlarm-500 can be made to activate by a command from the keypad. This output can be used for operating other devices such as; garage door opener, special lighting or door strikes.
  • Page 54: Remote Arming & Disarming

    System can be configured to arm and disarm by short, free call (see Chapter 5.3.2.5). In order to to arm the system, user calls GsmAlarm-500 number and, hearing the first signal, cancels the call. In this case there is no exit delay, the alarm system is activated immediately. After the armed mode is on, user receives a short confirmation call or SMS.
  • Page 55: System Operation In Alarm State

    S Y S T E M C O N T R O L 11. SYSTEM OPERATION IN ALARM STATE In the case of trespass of the protected area GsmAlarm-500, depending on the programmed system operation algorithm, switches the siren on, calls and sends SMS messages to five users (ALRNR1- ALRNR5).
  • Page 56: Gsm Jamming Detection

    5.3.2 or 5.7.17), the siren is activated upon detection of the jamming signal, and the user is informed thereof by an SMS message about it after clearing of GSM jamming signal. Siren operates with interruptions. The message indicates the jamming onset time: GSM Jamming detected! Time: 08:55 _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 57: System Control Using Dtmf And Sms Commands

    2-digit command is entered by pressing the key [*]. If the instruction is completed, user hears three tone confirmation signals. Speech mode can be activated in two ways: user answers when GsmAlarm-500 calls, or user calls and waits for GsmAlarm-500 to answer (3-4 call signals).
  • Page 58 IP address and connection port number. APN: GPRS access point name programming. APLOG: Programming of GPRS access point login name. APPASS: Programming of GPRS access point login password. PORT: GPRS access port number programming _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 59 SCON Switch on SmartCloud mode. SCOFF Switch off SmartCloud mode. SCPASS Receive SMS with the device ID and SmartCloud server login password. SCPASS: Change SmartCloud server login password. SMS instructions, for system programming and diagnostics _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 60: Smartcloud Server

    Save data into the device. • Create an account on web page sc.eltech.lt. Once you have an account, register one or more GsmAlarm devices. Create your own device name. Device identification number and login password are visible in the program GAprog field "SmartCloud server”.
  • Page 61: Warranty

    GSM network services, coverage and functioning. GsmAlarm-500 system provided with 36 months warranty. Warranty period starts with purchase date. If there are no purchasing documents, period counted starting from system manufacturing date (dated on security system identification label). Warranty is not valid if system: is reconstructed;...
  • Page 62: Technical Characteristics

    It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by “UAB ELEKTRONINES TECHNOLOGIJOS”. Manufacturer reserves the right to update or modify this document and/or related products without a warning. Copyright © 2016 ELEKTRONINES TECHNOLOGIJOS All rights reserved http://www.eltech.lt _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...
  • Page 63: Mounting Holes

    M O U T I N G H O L E S _________________________________________________________________________________ GsmAlarm-500 Software ver. 1.15...