AQUATECH RAPID/X6 Owner's Manual
Hide thumbs Also See for RAPID/X6:

Advertisement

Owner's Manual
RAPID/X6
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAPID/X6 and is the answer not in the manual?

Questions and answers

Harry Holland
February 24, 2025

can I adjust the mix of hot and cold water entering a household

1 comments:
Mr. Anderson
February 24, 2025

The AQUATECH RAPID/X6 does not control or limit the hot water pressure delivery in any way. The mix of hot and cold water is determined by your home's plumbing system, including pressure-restricting or tempering valves that may have been installed by your plumber. If you need to adjust the mix, you should check these valves or consult your plumber.

This answer is automatically generated

Summary of Contents for AQUATECH RAPID/X6

  • Page 1 Owner’s Manual RAPID/X6...
  • Page 2: Table Of Contents

    CONTENTS SAFETY WARNINGS ........................ 2 PARTS & CONSTRUCTION SCHEMATICS ........3 RAPID/X6 DIMENSIONS ..................3 Carefully read these operating and installation instructions and RAPID/X6 SCHEMATICS ..................4 keep them safe. Should this system INSTALLATION INSTRUCTIONS ................5 change hands, pass these instructions to the subsequent DELIVERY ...............................
  • Page 3: Safety Warnings

    1.0 SAFETY WARNINGS INSTALLATION & OPERATION • For outdoor use only. • DO NOT install or operate this system before reading the manufacturer’s instructions. • This appliance must be installed, commissioned and serviced by an authorized person in accordance with all applicable local rules and regulations. •...
  • Page 4: Parts & Construction Schematics

    Magnesium anode Cold water inlet 620mm The RAPID/X6 use a R290 (propane) refrigerant which is a flammable gas class 3 according to AS 1677 and must be handled by a refrigeration mechanic with an appropriate Australian refrigerant handling license. Warning - Risk of fire due to flammable material. If the refrigerant is leaked and there is...
  • Page 5: Rapid/X6 Schematics

    2.2 RAPID/X6 SCHEMATICS Top Lid Upper Cover 14, 15 Electronic Main Board Electronic Anode Transformer Fan Capacitor 7,8,9 AC to DC Transformer Compressor Run Capacitor 3,4,5, 6,13 Compressor Starter Capcitor Compressor Wiring Harness 17, 18 10. Compressor 1 1. Evaporator...
  • Page 6: Installation Instructions

    Do not tilt beyond 30° Aquatech heat pumps must be stored and transported in a near vertical position at all times with • a tilt ratio of no more than 30°. Transporting or storing the unit in a horizontal position will void warranty.
  • Page 7: Base

    Proper drainage should be observed for any overflow in accordance with AS/NZS 3500.2. • When installed the Aquatech unit must be completely vertical and level as to ensure that • condensate can be properly drained. If the system is installed at a level with a tilt of more than 3 degrees, warranties may be voided.
  • Page 8: Air Flow

    (when facing system) (see section 2.3 AIR FLOW). The Aquatech must be installed a minimum of 150mm off your home's wall so that the entire unit can be accessed during any servicing work as well as to prevent circulation of cold air (see section 2.3 AIR FLOW).
  • Page 9: Power Supply Tarrifs

    The Continuous tariff is what every household connected to the grid has as a minimum. If you would like to utilize a Solar PV system to run your Aquatech system on, this is usually the only tariff available to do so.
  • Page 10: Plumbing Schematics

    AS1056.1, AS/NZS2712, AS/NZ3350.240/30/30.2, AS3498 and represents an optimum installation procedure for this unit however to ensure minimum requirements are met all local regulations should be adhered too. 4.1 RAPID/X6 CONNECTION DIMENSIONS AND COMPONENTS Cold Water supply outlet (G 3/4” female thread) Hot Water Outlet (G 3/4”...
  • Page 11: Plumbing Installation

    5.0 PLUMBING INSTALLATION 5.1 PLUMBING CONNECTIONS 5.1.1 Cold water supply outlet The cold water supply connection is a G 3/4” female thread. • The cold water supply should be connected to G 3/4” socket. • The cold water supply outlet can also act as a drainage point for emptying the system. •...
  • Page 12 5.1.5 Tempering Valve RAPID/X6 systems are automatically programmed to produce hot water in excess of 50°C. As • such, in accordance with AS/NZS3500, it is mandatory that a Tempering Valve is installed.
  • Page 13 The non-return/isolation valve can be combined with a PRV valve to form a duo valve. • Filling the System: Once the Aquatech has been connected in accordance to Section 3.0 and 4.0 of • this handbook, the tank can be filled and pressurized.
  • Page 14: Electrical Connection

    6.0 ELECTRICAL CONNECTION Only qualified electricians may carry out the installations of the Aquatech heat pump to main power in accordance with the following instructions. 6.1 ELECTRICAL SCHEMATICS...
  • Page 15: Pre-Connection & Regulations

    Before any work can commence, ensure that the heater is isolated from the power supply at • the control panel. The RAPID/X6 heat pump is designed for permanent fixed wiring to either a Continuous Tariff • (single phase 240V AC supply) or a Shoulder Tariff (single phase 240V AC supply).
  • Page 16: Comissiong The System

    7.0 COMISSIONG THE SYSTEM 7.1 PRE=START PROCEDURES & CHECKS Once both the electrical and plumbing connections have been completed by qualified trades • person, the system is now ready for operation. Before turning the system on it is essential that you ensure the heat pump storage tank is full and •...
  • Page 17 INSTALLATION CHECKLIST The RAPID/X6 system is level. The RAPID/X6 system is installed on a concrete plinth or stable structure capable of sustaining weights in excess of 315kg. A minimum distance of 300mm is present above the RAPID/X6 system, to allow the lid to be removed for maintenance (see section 2.3 Air Flow).
  • Page 18: Operation Panel Instructions

    Please be aware of incoming water temperature seasonal changes, tariffs and usage patterns when customising timer periods. • Aquatech systems are pre-set at 60°C storage temperature to ensure the control of Legionella bacteria. • Temperature differential setting of 5°C (i.e. heap pump heating cycles begins at 55°C water temperature).
  • Page 19: Control Interface

    8.2 CONTROL INTERFACE Located on the front of the RAPID/X6 is the unit interface. It houses all the controls and displays necessary to operate your new RAPID/X6 system. CLOCK button UP & DOWN buttons ON/OFF button...
  • Page 20: Interface Icons

    8.3 INTERFACE ICONS The legend below indicates all components referred to in this manual. SYMBOL MEANING Screen is locked. Press any button to unlock. System is on. System is in heating mode. System is in defrost mode. Alarm representing a fault. Please take note of the error code beginning with “E”...
  • Page 21: Unlocking & Turning The System On

    1. Heat pumps work considerably more efficiently during daylight hours when ambient air temperatures are at their highest. 2. Having the RAPID/X6 system heat during the day is less likely to disturb anyone. 3. The in-built timers can be used to fully utilize a Solar PV system.
  • Page 22 The factory default for the in-built timer period is 09:00-18:00. RAPID/X6 systems will run using the timers when the following conditions are met: 1. The water temperature as shown on the display screen is below 55°C. 2. The time displayed on the screen is within the period designated by the set timers (factory default periods are 09:00-18:00.
  • Page 23: Setting The Clock

    8.6 SETTING THE CLOCK The correct time is necessary for the RAPID/X6 to operate using the timers. Please note that that the time is displayed in a 24-hour format. 1. Press the CLOCK button to begin setting the time. The hour value will begin flashing.
  • Page 24: Error Handling

    8.7 ERROR HANDLING RAPID/X6 systems will display an error code when a fault has occurred. The error message will show where the time is usually displayed as well as the error symbol. Please note the error code before contacting Aquatech directly.
  • Page 25: Trouble Shooting

    9.0 TROUBLE SHOOTING No hot water Possible causes Checks Solution If the screen is blank, check the supply power switch Check to see if the System has no power is turned on and that all homes fuses are up. If all fuses control screen is and cannot heat are down, contact your electrician or energy provider...
  • Page 26 The RAPID/X6 does not control or limit the hot water pressure delivery in anyway. If the pressure at your hot water taps is significantly reduced compared to your cold-water taps, contact your...
  • Page 27: Faq

    What should I do to the RAPID/X6 if I go away on holiday? Leave the system as per normal. The RAPID/X6 has built in safety features which will prevent Legionnaires' disease from occurring while you are away. The amount of electricity used by the system while there is no hot water being used is minimal.
  • Page 28: Warranty - Australia Only

    Owners can claim reimbursement for the following costs associated with a minor defect: All parts under section 1.2 SCHEMATIC RAPID/X6 will be supplied free of charge for a period of 5 Years from the date of install or manufacture.
  • Page 29 AS/NZS 4692.1:2005., when connected to a continuous power supply. A major failure can only be validated by an Aquatech approved service agent or plumber, or by the Aquatech Solar Technologies Pty. Ltd. service department. If a major failure is validated an approved agent will need to complete a Major Failure System Report (contact Aquatech directly for a copy).
  • Page 30 WARRANTY EXCLUSIONS This warranty does not cover any costs associated with the failure or damage of the Aquatech RAPID/X6 system under the following circumstances: Any failure of listed parts or complete system where the systems has not been installed in •...
  • Page 31 NON-RESIDENTIAL WARRANTY Where the Aquatech RAPID/X6 has been installed in any capacity not related to the supply of potable hot water at a temperature not in excess of 70°C, the installation will be deemed as non- residential and all warranties are void.
  • Page 32 NOTES...
  • Page 33 info@aquatechheatpumps.com.au www.aquatechheatpumps.com.au TOLL-FREE 1300 769 904...

Table of Contents