Commissioning
5.8
Default Heating Settings
The control system has two different default settings available from factory:
▪ radiator system (factory default)
▪ underfloor heating
The default settings will affect the heat curve settings and minimum and maximum supply line temperature. Further adjustments may
be necessary also after setting default settings.
Important: If the system shall be configured to Underfloor heating or similar, it is a must to set the heat pumps default value to floor
heating. If this is not done, the "factory reset" button will reset the heat curve and max/min supply line temperatures to default values
for radiator systems, which may cause damages on systems with e.g. floor heating.
To change default heat settings from Radiator to Floor heating (or reverse):
5.9
Network connection, Online
Thermia Online
The heat pump is factory prepared for monitoring (and as an additional service being operated) remotely via internet. (Thermia Online)
In order to use the Thermia Online service:
▪ Make sure that there is an available internet connection (router or equivalent) in the building
▪ An account and registration is required to use the Thermia Online service.
For more information, see:
www.thermia.com/documents
▪ Make a note of the heat pump MAC-address. The MAC-address is available in the Network menu in the display
Bear in mind that firewalls, deficient connections etc. can cause problems that will prevent desired functionality. Some operators, munic-
ipal networks etc. does not allow traffic through their firewalls.
Contact the internet service provider or network administrator if there are any such problems.
Connecting to internet
Connect the commissioned heat pump to an existing internet connection (router or equivalent). Use the RJ45 connection placed below
the display (CM module) behind the front panel. Use a patch cable (not cross over cable).
Network settings
In the Network settings DHCP (factory default) or Static IP-address can be selected. For DHCP, the router in the local network will provide
IP-address etc. See Menu settings.
If Static is selected, then IP-address, Network mask, IP gateway, DNS1 and DNS2 must be set manually. See Menu settings.
Thermia Värmepumpar
Diplomat Inverter/Diplomat Duo Inverter
1. Press
on the Start screen to open the Menu screen.
2. Press
3. Press
if the Heat curve window is not shown.
4. Press
for underfloor heating systems or
5. Make the desired changes.
6. Press
to set the new "factory reset" value to the selected system.
7. Confirm settings by pressing
for radiator systems
VIILM302
17