  • Page 1 10L Dehumidifier Model Number: RHDH1001 220-240V AC 50Hz 340W For Customer Services & Spare Parts please call 0345 209 7461 Or visit us at https://mda.russellhobbs.com PLEASE RETAIN FOR FUTURE REFERENCE...
  • Page 2: Table Of Contents

    CONTENTS Page(s) Safety Instructions and Electrical Safety 3 - 4 Feature Diagram Control Panel Diagram Positioning your Dehumidifier Using your Dehumidifier 8 – 13 Emptying your Dehumidifier 13 – 14 Cleaning and Care 15 – 16 Troubleshooting Guarantee and Customer Services Spare Parts Connection to the Mains Supply Specification...
  • Page 3: Safety Instructions And Electrical Safety

    Safety Instructions Important note: Please read this booklet before installing and switching on this appliance. The manufacturer assumes no responsibility for incorrect installation and usage as described in this booklet. • This model uses natural refrigerant gas as part of its cooling system. This gas is known as R290 (Propane) and is environmentally friendly but can be combustible.
  • Page 4 Safety Instructions • Do not use in the following locations:- Next to a source of fire. An area where oil is likely to splash. An area exposed to direct sunlight. An area where water is likely to splash. Near a bath, shower or a swimming pool. In a greenhouse.
  • Page 5: Feature Diagram

    FEATURE DIAGRAM Front Rear 1. Control panel 4. Handle 2. Air outlet grille 5. Air intake grille 3. Water tank 6. Air filter (behind the air intake grille) 7. Drain hose outlet 8. Power cord storage band 9. Power cord 10.
  • Page 6: Control Panel Diagram

    CONTROL PANEL DIAGRAM 1. Continuous dehumidifier mode indicator 2. Timer indicator 3. Defrost indicator 4. LED display 5. Water tank full indicator 6. Silent mode indicator 7. Power indicator 8. Continuous dehumidifier mode button 9. Timer button 10. Up control button 11.
  • Page 7: Positioning Your Dehumidifier

    POSITIONING YOUR DEHUMIDIFIER • This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications. • Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full drawer of water. •...
  • Page 8: Using Your Dehumidifier

    USING YOUR DEHUMIDIFIER When using the dehumidifier for the first time, run the unit in continuous mode for 24 hours When the water tank is full the unit will automatically shut off or when the tank is removed. The fan motor may continue for a period of 30 seconds after shut off, this is normal After the unit has stopped, the unit cannot be restarted for 3 minutes.
  • Page 9 USING YOUR DEHUMIDIFIER Continuous Dehumifier (Extraction) Mode • For maximum extraction rate, the Continuous Dehumidifier (Extraction) mode should be used. • Press the Continuous Dehumidifier (Extraction) button on the control panel. The Continuous Dehumidifier indicator light will illuminate when this mode is selected. •...
  • Page 10 USING YOUR DEHUMIDIFIER Setting the Timer Delayed Start • The unit must be switched OFF for the Auto Start function to be programmed. • With the unit switched off, press the Timer button until the Timer indicator light is illuminated. “0.0” will be displayed on the LED display. •...
  • Page 11 USING YOUR DEHUMIDIFIER Silent Mode • To reduce the noise output, for example, when being used at night, the silent mode can be activated. In this mode, the fan speed is slower and the unit will be running at a lower extraction rate. •...
  • Page 12 USING YOUR DEHUMIDIFIER Other features Auto Shut Off The dehumidifier will shut off automatically under the following conditions: • When the water tank is full • When the water tank is removed • When the water tank is not replaced in the proper position •...
  • Page 13: Emptying Your Dehumidifier

    USING YOUR DEHUMIDIFIER Error Codes P2 – Water drawer is full or drawer is not in the right position. Empty the drawer and replace in the correct position. AS - Humidity module sensor error. Unplug the unit and plug it back in. If error repeats, call customer service.
  • Page 14 EMPTYING YOUR DEHUMIDIFIER • When you remove the water tank, do not touch any parts inside of the unit. Doing so may damage the product. • Be sure to push the water tank gently all the way into the unit. Banging the tank against anything or failing to push it in securely may cause the unit not to operate.
  • Page 15: Cleaning And Care

    CLEANING AND CARE Cleaning the Air Filter The air filter is located behind the air intake grill on the rear of the appliance and should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT PUT THE FILTER IN AN AUTOMATIC DISHWASHER To Remove the Air Filter: •...
  • Page 16 CLEANING AND CARE Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. Cleaning the Grille and Case • Use water and a mild detergent. Do not use bleach or abrasives. • Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • Page 17: Troubleshooting

    TROUBLE SHOOTING Problem What to check • Unit does not start Make sure the dehumidifier’s plug is pushed completely into the socket outlet. • Check the house fuse/circuit breaker box. • Dehumidifier has reached its preset level or drawer is full. •...
  • Page 18: Guarantee And Customer Services

    GUARANTEE AND CUSTOMER SERVICES At Russell Hobbs, we take all our customer feedback seriously. Feel free to contact our Customer Service Team, on 0345 209 7461 who will be more than happy to assist you. This product is guaranteed for 12 months from the date of the original purchase.
  • Page 19: Spare Parts

    SPARE PARTS To check the availability of the following spare parts, simply contact our friendly Customer Services team using the details provided at the bottom of this page. Air Filter Drain Hose Bung For Customer Services & Spare Parts please call 0345 209 7461 Or visit us at https://mda.russellhobbs.com Page 19...
  • Page 20: Connection To The Mains Supply

    CONNECTION TO THE MAINS SUPPLY This appliance is designed to operate from a mains supply of 220-240V~ 50Hz. Check that the voltage marked on the product corresponds with your supply voltage. How to change the fuse 1. Slot the end of a screwdriver into the recess in the fuse holder of the plug.
  • Page 21: Specification

    Specification RHDH1001 Model 220 – 240V 50Hz Voltage 340W Power Input 10L per day (DB = 30 C RH = 80%) Moisture Removal R290/45g Refrigerant 21cm x 32cm x 40cm Overall Size (D x W x H) C - 35 Operating Temperature 11.4Kg...
  • Page 22: Notes

    Notes Page 22...
  • Page 23 Notes Page 23...
  • Page 24 For Customer Services & Spare Parts please call 0345 209 7461 Or visit us at https://mda.russellhobbs.com/ Revision 2 Model: RHDH1001 Made by G2S Ltd under license. G2S Limited, Wigan, WN2 4AY This symbol is known as the 'Crossed-out wheelie bin Symbol'.