When another compartment cannot make a decision for Cut-in/Cut-out (Caution)
30 minutes on, 40 minutes off
FRZ Eva Sensor Error/Frz Fan
Activated and stopped with the compressor.
It is operated at DC Fan x 1400 rpm.
FRZ Eva Sensor Error/Compressor
***NORMAL COOLING***
When another compartment cannot make a decision for Cut-in/Cut-out (Caution), 30
minutes on, 40 minutes off
If FF Air Sensor or FRZ Air Sensor is not faulty, it is operated in accordance with these
sensors.
FRZ Air Sensor Error/Defrost/Frz Fan
Fan is stopped unconditionally.(Frz defrost is not initiated when there is Frz Air sensor
error.)
FRZ Eva Sensor Error/Defrost/Frz Fan
Fan is stopped unconditionally.
FRZ Eva Sensor Error/Frz Defrost Heater
It is activated during the whole FRZ defrost process.
FRZ Eva Sensor Error/Defrost/Compressor
***NORMAL DEFROST***
Defrost input algorithm is the same.
Defrosting is stopped after 20 minutes.
9.12. Commissioning/Power Outage
When the refrigerator is energized, if the FF Eva sensor temperature is equal to or above 5°C, this is
called "commissioning". If this temperature is below 5°C, this is called "power outage".
10. ASSEMBLY/DISASSEMBLY OF PARTS
10.1. Upper Hinge Cover
Hinge cover is mounted on the hinge body with tabs, without using screws. To remove the cover,
simply pull it.
Sensitivity: Public
BEKO THAI NF 60 CM BOTTOM FREEZER REFRIGERATORS
38
09.03.2020 / REV NO: 01
Need help?
Do you have a question about the BFBF2414WH and is the answer not in the manual?
Questions and answers