Page 1
Table of contents 2007-09-05 Operating Manual Mixing Pump PFT G4 Article number of this Operating Manual: 00 10 20 92 Article number of the machine's parts list: 00 00 23 38 Doc ID: Knau-5991 Read this Operating Manual before starting work...
Page 2
This Operating Manual provides important instructions for working with the Knauf Mixing Pump PFT G 4 (hereinafter also referred to as the “machine”). For your own and the safety of others always strictly follow these instructions. Inform yourself about local accident prevention guidelines and general safety regulations.
Mixing Pump PFT G4 Table of contents General............5 Transport, packing, and storage....32 Explanation of symbols and signal Instructions for transport ....32 words ........... 5 Transport inspection......32 Disclaimer ..........7 Packaging...........33 Warranty terms ........7 Transport ..........34 Copyright ..........8 Operation.............35...
Page 4
Mixing Pump PFT G4 Table of contents Dismantling..........71 11 Appendix ............ 94 Safety..........71 11.2 Check list for annual expert inspection (copy template) ....96 Dismantling of the machine ....72 Disposal ..........72 Index ..............97 10 Replacement part lists....... 73 10.1 Material container and frame .....
General Pos: 1.1 /KN2006-SM/Allgemeines/100 1 Allgemeines_Titel @ 8\mod_1142088318714_293361.doc @ 293366 1 General Pos: 1.2 /KN2006-Projekte/Knauf/Allgemeines/Mischpumpe PFT G4/1.1 Symbolerklärung_ANSI @ 35\mod_1176467337081_293361.doc @ 435035 1.1 Explanation of symbols and signal words Safety messages in this Operating Manual can be identified by a safety alert symbol and/or signal words (see below).
Page 6
Mixing Pump PFT G4 General "NOTICE" is used to address practices not related to moderate injury but to property damage: Safety message text. Safety message text. Safety message NOTICE text. Safety message text. Safety message text. NOTICE! Safety message text. Safety message text. Safety message text.
Mixing Pump PFT G4 General Pos: 1.4 /KN2006-SM/Allgemeines/130 1.1 Haftungsbeschränkung @ 8\mod_1142091543501_293361.doc @ 293376 1.2 Disclaimer All information and instructions in this Operating Manual are provided with due consideration of applicable guidelines, the current state of the art, and our many years of experience within the industry.
Any violation of the manufacturer's copyright and other intellectual property rights will be prosecuted. Pos: 1.10 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 1.11 /KN2006-Projekte/Knauf/Allgemeines/Mischpumpe PFT G4/1.1 Ersatzteile_ANSI @ 35\mod_1176470713605_293361.doc @ 435164 1.5 Replacement parts Injury hazard if non-OEM parts are used!
Pos: 2.1 /KN2006-SM/Sicherheit/001 1 Sicherheit_Titel @ 8\mod_1142425976781_293361.doc @ 293586 2 Safety Pos: 2.2 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/001 1.0 Einführung (Maschine) @ 43\mod_1184929476207_293361.doc @ 515072 This section provides an overview of all the important safety aspects for the protection of personnel and third parties, and for safe and trouble-free operation of the machine.
When in doubt, speak to these persons and instruct them to leave the work area. Interrupt work as long as unauthorized persons are in the work area. Pos: 2.9 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Überprüfung @ 13\mod_1152630730927_293361.doc @ 298784 2.2.3 Inspection The machine must be inspected annually by a PFT representative (contact your local PFT dealer for further information).
Mixing Pump PFT G4 Safety Pos: 2.11 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Bestimmungsgemäße Verwendung_ANSI @ 35\mod_1176471681195_293361.doc @ 435236 2.3 Intended use The machine is designed and constructed exclusively for the following intended use: The machine is to be used exclusively for the use of factory pre- mixed and machine processable dry mortar up to a grain size of 3 mm (0.12 inches).
Follow the instructions that have been posted in the work area. Pos: 2.14 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/1.1.0_1 Grundsätzlich zu tragen_Titel (Maschine) @ 43\mod_1184934760511_293361.doc @ 515396 Always wear For all tasks always wear the following protective equipment when working with the machine: Pos: 2.15 /KN2006-SM/Sicherheit/006 Persönliche Schutzausstattung/Arbeitsschutzkleidung @ 8\mod_1143362598709_293361.doc @ 293403...
Mixing Pump PFT G4 Safety Pos: 2.23 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/1.1.0_2 Bei besonderen Arbeiten zu tragen_Titel (Maschine) @ 43\mod_1184935407141_293361.doc @ 515544 For special tasks wear Special protective equipment is required when executing special tasks. Separate reference is made to this equipment in the specific chapters of this Operating Manual.
Page 15
Wear light respiratory protection for all tasks in the danger zone. Pos: 2.36 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 2.37 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Schmutz und herumliegende Gegenstände_ANSI @ 35\mod_1176473939372_293361.doc @ 435502 WARNING! There is a danger of stumbling due to fouling and Fouling and loose objects loose objects! Fouling and loose objects on the ground pose slipping and stumbling hazards and can cause severe injuries.
See chapter "4 Structure and function" of this Operating Manual for more information on the location of the safety devices. Pos: 2.42 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/1.1.0 Folgende Sicherheitseinrichtungen sind installiert: (Maschine) @ 43\mod_1184938429953_293361.doc @ 515712 The following safety devices are installed on the machine: Pos: 2.43 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Hauptschalter als Not-Aus_ANSI @ 35\mod_1176474709905_293361.doc @ 435574...
Pos: 2.52 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 2.53 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Nicht in die laufende Maschine greifen Mischrohr @ 12\mod_1152262615284_293361.doc @ 298779 Injury hazard due to moving parts! Do not reach into the machine when it is running! There is a danger that extremities could be crushed, pulled in, or injured in some manner.
Page 19
Neglecting this warning may lead to severe injury or even death. Pos: 2.68 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 2.69 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Schutzhandschuhe (Struktur nach ANSI) @ 43\mod_1184942833460_293361.doc @ 515752 Protective gloves Wear protective gloves in areas that are identified by this label to protect the hands from friction, abrasion, puncture wounds, or deeper injuries as well as from contact with hot surfaces.
Page 20
Pos: 2.74 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 2.75 /KN2006-Projekte/Knauf/Sicherheit/Mischpumpe PFT G4/Nicht in laufende Maschine greifen @ 12\mod_1152259609889_293361.doc @ 298781 Running machine Do not reach into the machine when it is running. Be sure to switch the machine off and secure it against switching on before reaching into areas that are marked in this manner.
Mixing Pump PFT G4 Technical data Pos: 3.7 /KN2006-Projekte/Knauf/Technische Daten/Mischpumpe PFT G4/1.1 Anschlusswerte_Titel @ 43\mod_1184947694693_293361.doc @ 515814 3.2 Power and water supply Pos: 3.8 /KN2006-Projekte/Knauf/Technische Daten/Mischpumpe PFT G4/Wasseranschluß @ 12\mod_1152018923271_293361.doc @ 298800 Water connection Specification Value Unit Operating pressure, min.
Pos: 4.5 /KN2006-SM/Aufbau und Funktion/003 1.1 Kurzbeschreibung_Titel @ 9\mod_1144048508654_293361.doc @ 293621 4.2 Brief description Pos: 4.6 /KN2006-Projekte/Knauf/Aufbau und Funktion/Mischpumpe PFT G4/Kurzbeschreibung Text @ 12\mod_1152022663054_293361.doc @ 298813 The PFT G4 Mixing Pump is a continuous operation mixing pump for factory pre-mixed dry mortar. It can be filled with mortar delivered in bags as well as via transfer hood or injection hood.
Structure and function Pos: 4.8 /KN2006-SM/Aufbau und Funktion/004 1.1 Baugruppenbeschreibung_Titel @ 9\mod_1144046217018_293361.doc @ 293622 4.3 Module description Pos: 4.9 /KN2006-Projekte/Knauf/Aufbau und Funktion/Mischpumpe PFT G4/Baugruppenbeschreibung Text @ 12\mod_1152023193560_293361.doc @ 298810 The PFT G4 Mixing Pump consists of the following major components: Pos: 4.10 /KN2006-Projekte/Knauf/Aufbau und Funktion/Mischpumpe PFT G4/Baugruppen @ 12\mod_1152023931951_293361.doc @ 298806...
Page 27
Mixing Pump PFT G4 Structure and function Control panel: 1 Selector switch cellular wheel Manual-0-Automatic 2 Selector switch water pump Manual-0-Automatic 3 Indicator light "sense of rotation" 4 Main reverse switch, is concurrently an Emergency-Stop switch 5 Indicator light red, motor protection switch tripped 6 Button "water flow"...
Page 28
Mixing Pump PFT G4 Structure and function Water/air fitting: 1 Water connection 2 Manometer water operating pressure 3 Pressure switch – water 4 Pressure switch – air 5 Air for the sprayer 6 Manometer – air operating pressure 7 Air from pressure controller –...
Structure and function Pos: 4.14 /KN2006-SM/Aufbau und Funktion/009 1.1 Betriebsarten_Titel @ 9\mod_1144503262733_293361.doc @ 293630 4.5 Operating modes Pos: 4.15 /KN2006-Projekte/Knauf/Aufbau und Funktion/Mischpumpe PFT G4/Betriebsarten Zellenrad @ 12\mod_1152027474447_293361.doc @ 298812 Cellular wheel The cellular wheel can be operated in three different modes: "O"...
PFT transfer hood with no-load safeguard for G 4 (Item number 20 60 05 00) The PFT transfer hood is used for charging the PFT G 4 Mixing Pump with dry material directly from the silo / container. If there is an empty signal in the material container the mixing pump is switched off via the remote control socket.
Pos: 5.2 /KN2006-SM/Transport, Verpackung und Lagerung/002 1.1 Sicherheitshinweise für den Transport_Titel @ 9\mod_1144048644190_293361.doc @ 293649 5.1 Instructions for transport Pos: 5.3 /KN2006-Projekte/Knauf/Transport, Verpackung und Lagerung/Mischpumpe PFT G4/1.1.0 Warnung! Lebensgefahr durch schwebende Lasten_ANSI @ 36\mod_1177402705688_293361.doc @ 446932 Life-threatening hazard due to suspended loads!
Transport, packing, and storage Pos: 5.10 /KN2006-SM/Transport, Verpackung und Lagerung/005 1.1 Verpackung_Titel @ 9\mod_1144054971395_293361.doc @ 293656 5.3 Packaging Pos: 5.11 /KN2006-Projekte/Knauf/Transport, Verpackung und Lagerung/Mischpumpe PFT G4/1.1.0 Umgang mit Verpackungsmaterialien_ANSI @ 37\mod_1177403266189_293361.doc @ 447020 Improper disposal may cause environmental damage. NOTICE Packaging materials are valuable raw materials and in many cases they can be reused or effectively treated and recycled.
Fig. 15: Attachment points Pos: 5.17 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 5.18 /KN2006-Projekte/Knauf/Transport, Verpackung und Lagerung/Mischpumpe PFT G4/Transport der bereits im Betrieb befindlichen Maschine_ANSI @ 37\mod_1177403741188_293361.doc @ 447056 DANGER! Injury hazard due to ejecting mortar! Transport of a machine that is already in operation Face and eyes can be severely injured.
Mixing Pump PFT G4 Operation Pos: 6.7 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Vorbereitungen_Titel @ 36\mod_1177339531198_293361.doc @ 445806 6.2 Preparation Pos: 6.8 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Vorbereitung_ANSI @ 37\mod_1177404276344_293361.doc @ 447139 Prior to operating the machine execute the following work steps in preparation. DANGER! Running cellular wheel! Danger of serious injury when reaching into the running cellular wheel.
Page 37
Mixing Pump PFT G4 Operation 5. Ensure that the water inlet sieve (Fig. 20/1) is clean. Fig. 20: Water inlet sieve 6. Clean and vent the water hose. 7. Connect the water hose on the water hose connection and on the water inlet (Fig.
Page 38
Mixing Pump PFT G4 Operation Compaction by watering For heavy and dispersion-combined materials we recommend "compaction by watering" to enable easier pump start up. 9. If necessary have water on hand for compaction by watering: a) Remove the blind cover (Fig. 23/4) from the lower water duct (Fig.
Page 39
Mixing Pump PFT G4 Operation 11. Charge the machine with factory pre-mixed dry mortar. Charging can be executed with goods shipped in bags, with the transfer hood, or the injection hood, depending on the equipment. If charging with dry motar shipped in bags: WARNING! Sharp edges on the bag opener pose an injury hazard! Act carefully and wear safety gloves.
Mixing Pump PFT G4 Operation Pos: 6.10 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Einschalten und in Betrieb nehmen_Titel @ 36\mod_1177339967392_293361.doc @ 445833 6.3 Switching on and starting up Pos: 6.11 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Einschalten und in Betrieb nehmen @ 36\mod_1177340180513_293361.doc @ 445848 Switching on 1.
Page 41
Mixing Pump PFT G4 Operation Check the mortar consistency 5. Position the selector switch for cellular wheel (Fig. 30/1) "Manual-O-Auto" to "AUTO". 6. Switch on the machine via the green pushbutton (Fig. 30/2). The mortar will run out of the material connection.
Page 42
Mixing Pump PFT G4 Operation Connecting the sprayer 16. Switch off the machine via the "Operation OFF" pushbutton. 17. Connect the sprayer (2) to the mortar hose (1). Fig. 33: Connecting the sprayer 18. Ensure that the air cock ( /3) on the sprayer is closed.
Operation Pos: 6.16 /KN2006-SM/Bedienung/006 1.1 Ausschalten_Titel @ 9\mod_1144405011820_293361.doc @ 293692 6.5 Switching off Pos: 6.17 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Ausschalten @ 36\mod_1177340654631_293361.doc @ 445888 Position the selector switch "Manual-O-Auto" to "O". Pump out residual material until water escapes. Close air cock (Fig. 37/arrow) on the sprayer.
Mixing Pump PFT G4 Operation Pos: 6.19 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Reinigen_Titel @ 36\mod_1177341260047_293361.doc @ 445924 6.6 Cleaning Pos: 6.20 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Reinigen_ANSI @ 37\mod_1177405397896_293361.doc @ 447266 Damage due to improper cleaning after operation! NOTICE Always clean the machine on a daily basis after your work is completed.
Page 46
Mixing Pump PFT G4 Operation 5. Take the mixing pipe cleaner out of the retaining fixture ( Fig. /1). Fig. 41: Retaining fixture 6. Insert the cleaner shaft and mixing pipe cleaner ( /1) into Fig. 42 the mixing pipe with the scraper down.
Page 47
Mixing Pump PFT G4 Operation Removing the mortar hose 14. Remove the mortar hose ( /1) with the mortar pressure Fig. 44 manometer ( /2). Fig. 44 Fig. 44: Removing the mortar hose Rinse out the pump 15. Remove the blind cover ( /1) from the lower water duct Fig.
Page 48
Mixing Pump PFT G4 Operation 21. Insert the rinsing hose into the pressure flange and rinse out remaining deposits ( Fig. 47 Fig. 47: Rinsing out deposits Cleaning the mortar hose 22. Connect the plaster component (Fig. 48/1) to the mortar pressure connection (Fig.
Page 49
Mixing Pump PFT G4 Operation 25. Remove air nozzle pipe (Fig. 50/3) and fine plaster nozzle (Fig. 50/1) from the sprayer (Fig. 50/2). 26. Open the water removal valve until the sponge ball escapes at the fine plaster device. Repeat this process until the hose is clean.
Mixing Pump PFT G4 Operation Pos: 6.22 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Maßnahmen bei Frostgefahr_Titel @ 12\mod_1152191843426_293361.doc @ 298834 6.7 Measures if there is danger of freezing Pos: 6.23 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Maßnahmen bei Frostgefahr_ANSI @ 37\mod_1177406548654_293361.doc @ 447360 Damage due to freezing!
Page 51
Mixing Pump PFT G4 Operation Remove air hose (Fig. 54/3) on the sprayer. Fasten the hose on the water inlet (Fig. 54/1) and on the outlet of the air fitting (Fig. 54/2). 10. Close all water valves. 11. Switch on the machine (main switch on position "I").
Pos: 6.25 /KN2006-SM/Bedienung/007 1.1 Stillsetzen im Notfall_Titel @ 9\mod_1144405047456_293361.doc @ 293693 6.8 Shutdown in emergency situations Pos: 6.26 /KN2006-Projekte/Knauf/Bedienung/Mischpumpe PFT G4/1.1 Stillsetzen im Notfall, Anlage_ANSI @ 37\mod_1177407045808_293361.doc @ 447434 In case of an emergency, machine movements must be stopped immediately and the energy supply must be switched off.
2 of this Operating Manual. Pos: 7.2 /KN2006-SM/Störungen/002 1 Sicherheit_Titel @ 9\mod_1144439648502_293361.doc @ 293704 7.1 Safety Pos: 7.3 /KN2006-Projekte/Knauf/Störungen/Mischpumpe PFT G4/1.1.0 Personal --> Standard (Betriebsanleitung) @ 43\mod_1185106843413_293361.doc @ 544537 The troubleshooting described herein can be executed by the Personnel operator unless otherwise indicated within this Operating Manual.
Page 54
Prior to starting work switch off the machine and safeguard it from being switched on again. Pos: 7.11 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 7.12 /KN2006-Projekte/Knauf/Störungen/Mischpumpe PFT G4/1.1.0 Verhalten bei Störungen (Maschine) @ 43\mod_1185116899898_293361.doc @ 544567 Troubleshooting guidelines The following always applies:...
Mixing Pump PFT G4 Troubleshooting Pos: 7.19 /KN2006-SM/Störungen/005 1.1 Störungstabelle_Titel @ 9\mod_1144442349705_293361.doc @ 293711 7.3 Troubleshooting table Pos: 7.20 /KN2006-Projekte/Knauf/Störungen/Mischpumpe PFT G4/1.1 Störungstabelle @ 12\mod_1152526292830_293361.doc @ 298842 Problem Possible cause Corrective action to be corrected by Machine does Insufficient water pressure...
Page 57
Mixing Pump PFT G4 Troubleshooting Problem Possible cause Corrective action to be corrected by Machine does Too much thickened material in Empty half of the hopper and start Operator supply the hopper or mixing zone up the machine again mortar...
Page 58
Mixing Pump PFT G4 Troubleshooting Problem Possible cause Corrective action to be corrected by Machine does Air pressure safety switch is Adjust or replace the air pressure Service not switch off incorrectly adjusted or defective safety switch technician Air pressure hose defective or...
Page 59
Mixing Pump PFT G4 Troubleshooting Problem Possible cause Corrective action to be corrected by Mortar flow Clamp clip defective (oval) Replace clamp clip Service "thick-thin" technician Inner wall of the mortar hose is Replace mortar hose Operator defective Rotor is too deep in the pressure...
Troubleshooting Pos: 7.22 /KN2006-SM/Störungen/006 1.1 Arbeiten zur Störungsbehebung_Titel @ 9\mod_1144442554841_293361.doc @ 293713 7.4 Troubleshooting work Pos: 7.23 /KN2006-Projekte/Knauf/Störungen/Mischpumpe PFT G4/1.1.1 Beseitigen von Schlauchverstopfern_ANSI @ 37\mod_1177408303165_293361.doc @ 447744 7.4.1 Eliminating hose blockage To be performed by a service technician only. Additionally required protective equipment:...
Mixing Pump PFT G4 Troubleshooting Pos: 7.25 /KN2006-Projekte/Knauf/Störungen/Mischpumpe PFT G4/1.1.1 Maßnahmen bei Stromausfall_ANSI @ 37\mod_1177408601419_293361.doc @ 447759 7.4.2 Measures in the event of power failure To be performed by a service technician only. DANGER! Excess pressure on the machine! When opening machine components these components can unexpectedly fly open and seriously injure the operator.
Protective work clothing Protective goggles Protective gloves Safety footwear Pos: 8.5 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.0 Elektrische Anlage_ANSI @ 37\mod_1177409893009_293361.doc @ 447800 Life-threatening danger due to electric shock! DANGER There is a danger to life when touching or coming into contact with live components. Running electrical components can move unexpectedly and can cause serious injuries or possibly death.
Only clean the exterior machine parts with a damp cloth. Pos: 8.13 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 8.14 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1 Wartungsplan_Titel (Betriebsanleitung) @ 43\mod_1185118787001_293361.doc @ 544582 8.3 Maintenance schedule Maintenance tasks that are required for optimal and trouble-free operation are described in the sections below.
Fig. 63: Brass sieve in the water inlet Pos: 8.20 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 8.21 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.1 Filter des Kompressors reinigen @ 36\mod_1177346697691_293361.doc @ 446046 8.4.2 Clean the compressor filter To be performed by the operator.
Mixing Pump PFT G4 Maintenance Pos: 8.23 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.1 Schmutzfängersieb reinigen @ 36\mod_1177346898000_293361.doc @ 446059 8.4.3 Clean the debris collector sieve To be performed by the operator. 1. Unscrew the pressure reducer's screw plug (Fig. 65/1). 2. Take out the debris collector sieve (Fig. 65/2) and clean it 3.
Mixing Pump PFT G4 Maintenance Pos: 8.25 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.1 Einstellwerte Druckschalter prüfen @ 36\mod_1177347068497_293361.doc @ 446072 8.4.4 Check the set values of the pressure switch To be performed by a service technician. If problems occur at an increasing rate the pressure switch should be readjusted.
Mixing Pump PFT G4 Maintenance Pos: 8.27 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.1 Drücke und Einstellwerte prüfen @ 36\mod_1177348092466_293361.doc @ 446098 8.4.5 Check pressure and set values Pressure reducer valve Adjust a pressure of 1.9 bar (27.6 psi) at maximum passage on the pressure reducer valve (Fig. 70).
Mixing Pump PFT G4 Maintenance Pos: 8.29 /KN2006-Projekte/Knauf/Wartung/Mischpumpe PFT G4/1.1.1 Kontrollieren des Förder- und Rückstaudruckes @ 13\mod_1152625868222_293361.doc @ 298847 8.4.6 Check delivery pressure and back pressure To be performed by the operator. Special tools required: PFT pressure tester with coupling and drain cock (to be order under the item no.
Only certified electricians should perform work on the electrical equipment. Pos: 9.6 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 9.7 /KN2006-Projekte/Knauf/Demontage/Mischpumpe PFT G4/1.1.0 Grundlegendes_ANSI (Maschine) @ 37\mod_1177411192715_293361.doc @ 447866 Improper dismantling poses an injury hazard! WARNING Stored residual energy, sharp-edged components, points and corners on and in the machine, or on the necessary tools can cause serious injuries.
Mixing Pump PFT G4 Dismantling Pos: 9.11 /KN2006-Projekte/Knauf/Demontage/Mischpumpe PFT G4/1.1 Demontage (Maschine) @ 36\mod_1177398355245_293361.doc @ 446722 9.2 Dismantling of the machine For sorting, clean the machine and dismantle it in compliance with applicable industrial safety and environmental protection guidelines. Prior to disassembling: Switch off the machine and safeguard it from being restarted.
Appendix Pos: 11.3 /KN2006-SM/nL---------- Abschnittsende ---------- @ 8\mod_1141997892953_0.doc @ 293763 Pos: 11.4 /KN2006-Projekte/Knauf/Anhang/Mischpumpe PFT G4/1.1 Checkliste für jährliche Sachkundigen-Prüfung @ 13\mod_1152699823584_293361.doc @ 298868 11.2 Check list for annual expert inspection (copy template) The expert inspection must be executed once a year in accordance with applicable rules and regulations.
Need help?
Do you have a question about the PFT G4 and is the answer not in the manual?