READ THOROUGHLY BEFORE INSTALLING
WARNING
Risk of electric shock
• Turn power off before servicing
– see instructions
WARNING
Risk of fire
• Use supply wire specified on
nameplate
G E N E R A L
Versaflood II Wallighter
This luminaire is designed for outdoor lighting service,
and should not be used in areas of limited ventilation, or in
high ambient temperature enclosures. Best results will be
obtained if installed and maintained according to the
following recommendations.
Versaflood II Industrial Wallighter
This luminaire is designed for elevated ambient outdoor
or indoor lighting service. See nameplate for ambient ratings
versus wattage. Best results will be obtained if installed and
maintained according to the following recommendations.
U N P A C K I N G
This luminaire has been properly packed so that no parts
should have been damaged during transit. Inspect to
confirm.
CAUTION
Unit will fall if not installed properly
• Follow installation instructions
I N S T A L L A T I O N
1. Remove door by loosening the door and hinge screws and
opening at least 30° and pushing or bumping the door
toward the hinge so that the hinge springs slide over the
hinge pin.
2. Remove the reflector by removing the center screw,
loosening the two flange screws and disconnecting the
socket connector.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred
to GE Lighting Solutions.
Versaflood
3. Remove the protective insulation shield.
4. Versaflood II Wallighter
For surface mounting there are four 0.438-in. (11mm)
diameter knockouts provided and a 0.875 (22mm)
diameter knockout for the back wiring entrance. This unit
is also provided with three -inch diameter threaded
conduit entrances, one at the top and one on each side.
Versaflood II Industrial Wallighter
For surface mounting there are four 0.438 in. (11mm)
diameter knockouts provided. Back wiring entrance is not
permitted. This unit is also provided with three 0.75-in.
(19mm) diameter threaded conduit entrances, one at the
top and one on each side.
NOTE: Do not use the rear outlet box wiring entrance
with series V2IW fixtures.
PHOTOELECTRIC
CONTROLS
(Versaflood II Wallighter Only)
Photoelectric control receptacle (if present) should be
oriented before control is installed. Loosen the two holding
screws and rotate receptacle until "NORTH'' is directed as
near as possible to true North. Tighten holding screws and
install control.
WIRING
To assure against heat damage to leads, position all
leads to prevent contact with reflector.
Make all electrical connections in accordance with
the National Electrical Code and any applicable local
code requirements.
CONNECTIONS FOR SINGLE AND
DUAL-RATED UNITS
Terminals are readily accessible on the terminal board
and will accept No. 14 through No. 6 wire. Attach the service
leads to the terminal board as shown on the luminaire
nameplate.
GEH-5808
INSTRUCTIONS
II Wallighter
®

Advertisement

loading

Summary of Contents for GE Versaflood II

  • Page 1 • Turn power off before servicing – see instructions WARNING 3. Remove the protective insulation shield. 4. Versaflood II Wallighter Risk of fire • Use supply wire specified on For surface mounting there are four 0.438-in. (11mm) diameter knockouts provided and a 0.875 (22mm) nameplate diameter knockout for the back wiring entrance.
  • Page 2 be securely inserted to the NEMA-EEI specified torque of 35- Verify that supply voltage is correct by comparing it inch pounds, which is best achieved by very firm tightening to nameplate. sufficient to fully depress and load the center contact of the socket.
  • Page 3 Ces instructions n'ont pas pour destination de couvrir tous les détails ou variantes de l'équipement, ni de répondre à toutes les éventualités que vous pourriez rencontrer pendant l'installation, le fonctionnement ou l'entretien. Si vous souhaitez des informations complémentaires, ou si vous rencontrez un problème particulier qui ne soit pas adressé de votre point de vue d'acheteur, le sujet doit être remonté jusqu'à la société GE Lighting Solutions...
  • Page 4 4 3 5 3 3 GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.