Mini Rythmic
PN+
Set-up Guide
Training videos are also available:
please contact your hospital for further information.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini Rythmic PN+ and is the answer not in the manual?

Questions and answers

Summary of Contents for Inspiration Mini Rythmic PN+

  • Page 1 Mini Rythmic ™ Set-up Guide Training videos are also available: please contact your hospital for further information.
  • Page 2 Inspiration Healthcare Hospital Nutrition Team Telephone No. Homecare Company Telephone No. Current Pump Serial No.
  • Page 3 Mini Rythmic ™ Mode - Enter Code 0112 Volume Over Time Intermittent Auto Ramp Continuous 25 Steps (1) Purge button used to prime non gravity giving set (2) On/off button one button with dual action (3) Soft touch buttons with multi-functions (4) Enter button used to confirm entries (5) Start/Stop button...
  • Page 4 Inspiration Healthcare Programming the Pump Turn pump on by pressing and holding button (2) enter code 0111; press enter button (4) Ensure the pump is in the correct mode Select required programme New Patient Programme (Volume Over Time) Set bag volume press enter button (4) Set volume to be infused (VTBI);...
  • Page 5 Mini Rythmic ™ New Patient Programme (Continuous) Set required rate; press enter button (4) Set volume; press enter button (4) Screen will now confirm all details entered; press enter button (4) Pump on Hold if all details correct; double press start/stop button (5) to start the pump New Patient Programme (25 steps) Set bag volume;...
  • Page 6 Inspiration Healthcare Priming the giving set Manual Priming 1. Spike the bag – keep filter vertical, any air will be eliminated via the filter. 2. Press priming button (do not use a sharp object) until filter is saturated. 3. Turn the priming button upside down, continue to press until the giving set is fully primed.
  • Page 7 Mini Rythmic ™ Pump Priming Close clamp prior to spiking the bag. Load giving set into pump and follow pump programming until pump on hold. Hold the pump in a vertical position with the blue clamp at the bottom. Press purge button (1) to commence priming. When giving set is fully primed;...
  • Page 8 Inspiration Healthcare Battery The 9v battery is not rechargeable and will require replacement. A low battery warning will appear. The battery life of a 9v alkaline battery (new and unused) is: 8.5 hours minimum at 150ml/hr 8.5 hours minimum at 200ml/hr 8 hours minimum at 250ml/hr 7.5 hours minimum at 300ml/hr...
  • Page 9 Mini Rythmic ™ IP Connect The IP Connect pack is used in conjunction with the discharging hospital. This pack is charged in the same way and has the same battery life as the External Battery Pack (see page 8 for information).
  • Page 10 Inspiration Healthcare Keep Vein Open Alarm will sound when pump goes into Keep Vein Open mode. Press enter button (4) to silence the alarm Keep Vein Open will only function if the bag volume is greater than the VTBI Pump Unattended Intermittent alarm will sound when the pump is on hold or no button has been pressed or pump started.
  • Page 11 Mini Rythmic ™ Depleted External Battery Press key below bell sign twice to silence the alarm Change to fully charged External Battery pack or connect to mains power supply Air in line Press button (4) to silence alarm Message will show ‘Air in line’ setting Turn pump off;...
  • Page 12 The details given in this leaflet are correct at time of going to press. The company reserves the right to improve the products shown. 500-402(7) 2017-05 +44 (0)1455 840 555 info@inspiration-healthcare.com inspiration-healthcare.com...