WARNING:
Turn OFF the Salt Water System and UNPLUG from the power outlet before troubleshooting.
Problem
A. The System not plugged in
B. GFCI Power Cord Set
breaker tripped
1. System
doesn't start
A. Low voltage
D. In STANDBY mode, LED blinks every 5
seconds.
A. Loose connections at the Electrolytic
Cell
s
B. The red LED of Water Flow Sensor
is on
2. System not
working
C. The Electrolytic Cell
is too dirty
D. Timer Indicators
to STANDBY mode)
A. Salt Status Indicator
(low salt level)
B. Salt Status Indicator
(high salt level)
C. Cell Status Indicator
3. Chlorine level
(Electrolytic Cell
issues
D. Cell Status Indicator
(Electrolytic Cell
E. Incorrect inlet and outlet hose direction
A. Cell Inlet
B. Cell Outlet
4. Water
leakage at
C. Cell Lock Nut
D. Cell O-Rings
TROUBLESHOOTING GUIDE
Cause/Symptom
and/or circuit
k
d
or Cell Inlet
s
u
are off (System back
2
turns red
5
turns orange
5
turns orange
6
is in poor condition)
s
turns red
6
failure)
s
u
or Hose
g
x
j
i f
OWNER'S MANUAL
A. Plug the System into a 3-wire grounded power outlet.
B. Reset the Set or the circuit breaker. If problem persists, have the circuit
checked by a qualified electrician.
C. Check and make sure the line voltage is between 105VAC and 125VAC.
A. Press and HOLD the Power/Mode Button
on the System.
A. Make sure the cord connectors are tightened, and the Cell Cover
firmly connected. See ELECTROLYTIC CELL REPLACEMENT
Lock Nut
j
(p. 19).
B. See CLEANING THE WATER FLOW SENSOR (p. 17) to clean the Sensor,
or replace the entire Electrolytic Cell.
C. Hose clean the Cell or Inlet, or replace the entire Cell.
D. Press and HOLD the Power/Mode Button
on the System.
A. Add salt to water until the light turns green.
B. Drain some pool water and refill with fresh water until the light turns green.
C. Hose clean the Cell. If the LED remains orange, replace with a new Cell
immediately.
D. Replace with a new Cell immediately.
E. See SETUP INSTRUCTIONS (p. 10) and check that the inlet and outlet
hose directions are correct.
A1. Check that the Metal Hose Clamp
A2. Check the O-Ring
for damage, and replace as needed.
i
A3. Check the hose between the Cell and filter pump (if any) for cracks or
holes and replace as needed.
B1. Check that the Plastic Hose Clamp
B2. Check the O-Ring
for damage, and replace as needed.
f
B3. Check the Hose for cracks or holes and replace as needed.
C. Check to make sure that the Nut is tightened properly to seal the connection
between the Cell Case
and Cell Cover
o
See Step 9 of ELECTROLYTIC CELL REPLACEMENT (p. 19).
D. Check for damage and replace as needed. Lubricate the O-Rings with
petroleum jelly (not included).
Solution
for at least 2 seconds to turn
8
for at least 2 seconds to turn
8
is properly tightened.
;
is properly tightened.
t
.
h
and Cell
h
21
Need help?