Advertisement

Run 1500
Pressure die-cast
aluminium base and release,
with epoxy painting
Code
Description
RUN1500
Irreversible, 24 Vdc, with built-in control unit,
with electromechanical limit switch,
for sliding gates weighing up to 1500 kg
RUN1500P
Irreversible, 24 Vdc, with built-in control unit,
with inductive limit switch,
for sliding gates weighing up to 1500 kg
Technical specifi cations
Code
Electrical data
Power supply (Vac 50/60 Hz)
Absorption (A)
Power (W)
Performance data
Speed (m/s)
Force (N)
Work cycle (cycles/hour)
Dimensional and general data
Protection level (IP)
Working temp. ( °C Min/Max)
Dimensions (mm)
Weight (kg)
80
Nice Gate&Door
Compartment
for control unit
protected by
removable box
Pack/pallet
12
12
RUN1500/1500P
230
2
400
0.25
1000
60
44
-20 ÷ +50
400x255x390 h
19
For sliding gates weighing
up to 1500 kg.
Versions with electromechanical
limit switch (RUN1500) and with
inductive limit switch (RUN1500P).
User-friendly: the BlueBUS technology,
enables to power and control a maximum
of 7 couples of photocells from the MoonBus
series using two wires only.
Practical: the control unit and PS124
buffer battery (optional) can be connected
by means of a simple connector
and can be housed directly inside the motor.
Advanced: the temperature sensor adapts
the motor force to weather conditions,
setting the thermal cut-out protection
accordingly; a master/slave selection
automatically synchronises 2 motors,
enabling the automation of sliding gates
with two opposing leaves.
Intelligent: thanks to the obstacle detection
system and automatic programming
of the working times.
Self-diagnosis by means of a fl ashing light.
8 programming levels.
Safe: acceleration and deceleration
can be adjusted at the beginning and end
of each opening and closing manoeuvre.
Sturdy: aluminium release handle
for easy opening.
Very quiet: gear motor on bearings.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RUN1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nice RUN1500

  • Page 1 Run 1500 For sliding gates weighing up to 1500 kg. Versions with electromechanical limit switch (RUN1500) and with inductive limit switch (RUN1500P). User-friendly: the BlueBUS technology, enables to power and control a maximum of 7 couples of photocells from the MoonBus series using two wires only.
  • Page 2 RB400, RB600/600P, with integrated 22x22x1000 mm. zinc coated with spacers Pc/pack 1 RB1000/1000P battery charger. and screws. Pc/pack 10 and RUN1500/1500P. Pc/pack 1 Pc/pack 10 Pc/pack 1 ROA81 RUA12 M6 rack, 30x30x1000 mm, 12-teeth pinion, Signboard. zinc coated, to be...
  • Page 3 Sliding Gate Opener RUN1800 RUN1800P RUN2500 RUN2500P Instructions and warnings for the fitter Istruzioni ed avvertenze per l’installatore Instructions et recommandations pour l’installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i uwagi dla instalatora Aanwijzingen en aanbevelingen voor de installateur...
  • Page 4: Table Of Contents

    1800/1800P 2500/2500P Table of contents: page Warnings 7.2.1 Level one functions (ON-OFF functions) 7.2.2 Level one programming Product description and applications (ON-OFF functions) Operating limits 7.2.3 Level two functions Typical system (adjustable parameters) List of cables 7.2.4 Level two programming (adjustable parameters) Installation 7.2.5...
  • Page 5: Warnings

    Directive if used in the configurations foreseen in this instruction Visit “www.niceforyou.com” for further information and guidelines for risk manual and in combination with the articles present in the Nice S.p.a. analysis and how to draw up the Technical Documentation. This manu- product catalogue.
  • Page 6: Product Description And Applications

    2) Product description and applications RUN is a range of irreversible electromechanical gearmotors used for is also available at: www.niceforyou.com. RUN is equipped with a the automation of sliding gates. They are equipped with an electron- connector for remote programming units to enable complete and ic control unit and an “SM”...
  • Page 7 Table 3: limits in relation to the weight of the leaf RUN1800/ RUN1800P RUN2500/ RUN2500P Leaf weight (kg) Cycle percentage Cycle percentage Up to 500 100% 100% 500 ÷ 900 900 ÷ 1200 1200 ÷ 1500 1500 ÷ 1800 2000 ÷ 2300 2300 ÷...
  • Page 8: Typical System

    2.2) Typical system Figure 2 shows a typical system for automating a sliding gate using RUN. Key-operated selector switch Rack Receiver FT210B Flashing light with incorporated aerial Photocells Transmitter FT210B 10 “Closed” limitswitch bracket Primary movable edge 11 Primary movable edge (optional) “Open”...
  • Page 9: Installation

    3) Installation The installation of RUN must be carried out by qualified personnel in compliance with current legislation, standards and regulations, and the directions provided in this manual. 3.1) Preliminary checks Before proceeding with the installation of RUN: • Ensure that the mounting positions of the various devices are pro- •...
  • Page 10: Fixing Of The Limit Switch Bracket On Versions With Inductive Limit Switch

    6. Release the gearmotor as shown in “Release and manual move- In order to prevent the weight of the leaf from affecting ment” paragraph in the Chapter “Instructions and Warnings for the gearmotor, it is important that there is a play of 1÷2 users of the RUN gearmotor”.
  • Page 11: Installation Of The Various Devices

    3.4) Installation of the various devices If other devices are required, install them following the directions provided in the corresponding instructions. Check this in paragraph “3.6 Description of electrical connections” and the devices which can be connected to the RUN in Figure 2. 3.5) Electrical connections the diameter of the cables joined by the clamp, and slide the Only carry out electrical connections once the electric-...
  • Page 12: Description Of The Electrical Connections

    3.6) Description of the electrical connections The following is a brief description of the electrical connections; for special procedures on the input. For more useful information about further information please read “7.3 Adding or Removing Devices” STOP see also Paragraph “7.3.2 STOP Input”. paragraph.
  • Page 13: Leaf Length Self-Learning

    4.4) Leaf length self-learning After self-learning the devices, leds L3 and L4 start flashing; the control unit must self-learn the length of the gate. During this stage, the length of the leaf is measured from the closing limit switch to the opening limit switch. This measurement is required to calculate the decel- eration points and the partial opening point.
  • Page 14: Testing

    5.1) Testing Each component of the system, e.g. safety edges, photocells, emer- stopping of the gate and make sure that the leaves move in the gency stop, etc. requires a specific testing phase. We therefore rec- intended direction. ommend observing the procedures shown in the relative instruction 6.
  • Page 15: Additional Information

    7) Additional information Programming, personalisation and how to look for and deal with faults on the RUN will be dealt with in this chapter. 7.1) Programming keys The RUN control unit feature three keys that can be used to command the control unit both during tests and programming: Open The “OPEN”...
  • Page 16: (Adjustable Parameters)

    7.2.2) Level one programming (ON-OFF functions) Level 1 functions are all factory set to “OFF”. However, they can be changed at any time as shown in Table 8. Follow the procedure careful- ly, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will fin- ish automatically and memorize the modifications made up to that stage.
  • Page 17: (Adjustable Parameters)

    Input LED Parameter Led (level) Value Description 0,5 mt 1 mt The measurement of the partial opening. Par- 1,5 mt tial opening can be controlled with the 2nd Partial Open 2 mt radio command or with “CLOSE”, if the “Clo- 2,5 mt se”...
  • Page 18: Level One Programming

    7.2.5) Level one programming example (ON-OFF functions). The sequence to follow in order to change the factory settings of the functions for activating “Automatic Closing” (L1) and “Always close” (L3) have been included as examples.). Table 11: Level one programming Example Press and hold [Set] (approx.
  • Page 19: Stop Input

    7.3.2) STOP input STOP is the input that causes the immediate interruption of the • Two devices with 8.2KΩ constant resistance output can be con- manoeuvre (with a short reverse run). Devices with output featuring nected in parallel; if necessary, multiple devices must be connect- normally open “NO”...
  • Page 20: Run In "Slave" Mode

    7.3.5) RUN in “Slave” mode When correctly programmed and connected, RUN can function in “Slave” mode; this type of function is used when 2 opposite gates need to be automated with the synchronised movement of the two leaves. In this mode RUN works as Master commanding the move- ment, while the second RUN acts as Slave, following the commands transmitted by the Master (all RUN are Masters when leaving the fac- tory).
  • Page 21: Self-Learning Other Devices

    Table 14: RUN Slave programming independently from RUN Master Level one functions (ON-OFF functions) Level two functions (adjustable parameters) Stand-By Obstacle detection sensitivity Peak Open Gate Indicator output Slave Mode Motor torque control Fault list • A command device (Step by Step) that controls the complete On Slave it is possible to connect: •...
  • Page 22: Connection Of Other Devices

    Check of number of manoeuvres performed The number of manoeuvres performed as a percentage of the set limit can be verified by means of the “Maintenance warning” function. Follow the indications in table 17 for this check. Table 17: check of the number of manoeuvres performed Example Press and hold [Set] (approx.
  • Page 23: Troubleshooting

    7.6) Troubleshooting Table 19 contains instructions to help solving malfunctions or errors that may occur during the installation stage or in case of failure. Table 19: Troubleshooting Symptoms Recommended checks The radio transmitter does not control the gate Check to see if the transmitter batteries are discharged, if necessary replace them and the LED on the transmitter does not light up.
  • Page 24: Flashing Light Signalling

    7.7.1) Flashing light signalling During the manoeuvre the flashing light FLASH flashes once every second. When something is wrong the flashes are more frequent; the light flashes twice with a pause of a second between flashes. Table 21: FLASH flashing light signalling Quick flashes Cause ACTION...
  • Page 25: Accessories

    The following optional accessories are available for RUN: • OperaView; Remote programming unit. • SMXI or SMXIS: Radio receiver at 433.92MHz with digital Rolling Consult the Nice S.p.a. product catalogue for the complete and Code encoding. updated list of accessories.
  • Page 26: Technical Characteristics

    8) Technical characteristics With the aim of improving products, Nice S.p.a reserves the right to modify technical characteristics at any time without notice, while main- taining the same functionalities and intended use. All technical characteristics stated refer to an ambient temperature of 20°C (±5°C).
  • Page 27: Instructions And Warnings For Users Of Run Gearmotor

    This operation equipped with detection devices that prevent move- has been carefully designed by Nice to make it ment if people or objects are in the way, guaranteeing extremely easy, without any need for tools or physical safe and reliable activation.
  • Page 28 Nice products. You will get the the control is released the gate will stop. services of a specialist and the most advanced pro-...
  • Page 30 Headquarter Nice worldwide Nice España Madrid Nice Romania Tel. +34.9.16.16.33.00 Cluj Napoca Nice SpA Nice France Fax +34.9.16.16.30.10 Tel/Fax +40.264.45.31.27 Oderzo TV Italia Buchelay info@es.niceforyou.com info@ro.niceforyou.com Tel. +39.0422.85.38.38 Tel. +33.(0)1.30.33.95.95 Fax +39.0422.85.35.85 Fax +33.(0)1.30.33.95.96 Nice España Barcelona Nice Deutschland info@niceforyou.com info@fr.niceforyou.com...
  • Page 31 Nota - Il contenuto di questa dichiarazione corrisponde a quanto dichiarato nell’ultima revisione disponibile, prima della stampa di questo manuale, del documento ufficiale deposi- tato presso la sede di Nice Spa. Il presente testo è stato riadattato per motivi editoriali. / Note - The contents of this declaration correspond to those of the last revision available...
  • Page 32 7 m, mientras que RUN1500 sirve para automatizar puertas con un peso de hasta 1500 kg o bien una longitud máx, de 14 rend RUN1500 in der Lage ist, Tore mit einem Gewicht bis zu 1500 kg oder einer Länge bis zu 14 m zu automatisieren (siehe Tabelle 1 und 2). Auf- m;...

This manual is also suitable for:

Run1500pRun1800Run1800pRun2500Run2500p

Table of Contents