Do you have a question about the 72-2535 and is the answer not in the manual?
Questions and answers
Kailasam Rupasree
April 10, 2025
i was taking remote control of the tenma 72-2540 power supply, i want to know in that is their any delay to set voltage or current as well as on/off. i was getting 50msec delay i want to reduce that delay.
Front Panel Overview Display Condition Indication • OVP is the indicator of overvoltage protection. • When the overvoltage function is turned on the “ ” indicator lights up. • W hen the output voltage is higher than the protection setup value, due to unexpected conditions, the output cuts off and the OVP indicator flickers. • Press the OVP key again and the power supply will recover. OCP is OCP indicator.
Brief Introduction of Panel Operation Operation Connect the AC power cord and select the corresponding AC voltage according to the back label, then connect the AC power cord to the socket on the back panel. Press the power switch to turn the power on. The display initialises, showing the model of the machine and then the setting level, which is recalled from the last use.
Output ON/OFF Panel Operation • The key LED will turn on once you have pressed the “output” key to turn output on. • The key LED will then turn off once you have pressed the “output” key again to turn off output. Note: If there are any of the following conditions, the output will automatically turn off: • OVP means there is abnormal high voltage output or input on the output terminal. • ...
Functionality Check • Run this query command via the terminal application, such as MTTTY (Multithreaded TTY). • This should return the idenitifcation information: Manufacturer, model name, serial number, TENMA 72-2535 SN:xxxxxxxx Vx.xx Entering the Remote Control Mode: • Connect the USB.
Page 8
4. NR2: parameter Command Details: 1. ISET<X>:<NR2> Description: Sets the output current. Example :ISET1:2.225 Sets the CH1 output current to 2.225A 2. ISET<X>? Description: Returns the output current setting. Example: ISET1? Returns the CH1 output current setting. 3. VSET<X>:<NR2> Description: Sets the output voltage. Example VSET1:20.50 Sets the CH1 voltage to 20.50V 4.
Need help?
Do you have a question about the 72-2535 and is the answer not in the manual?
Questions and answers
i was taking remote control of the tenma 72-2540 power supply, i want to know in that is their any delay to set voltage or current as well as on/off. i was getting 50msec delay i want to reduce that delay.