Keypad - KEYZB-110 – Technical manual 4.2.5 Time – Cluster id 0x000A ....................................15 4.2.5.1 Attribute ..........................................15 MMI user guide ............................................16 Panel description ..........................................16 Menu button ............................................17 5.2.1 EZ mode - Initiator ......................................... 18 5.2.2 EZ mode - Target ........................................18 5.2.3...
Page 4
Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein.
Develco Products A/S reserves the right to make changes to any product to improve reliability without further notice. Develco Products A/S does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under patent rights or the rights of third parties.
Keypad - KEYZB-110 – Technical manual 2 Features Keypad - KEYZB-110 Enables secure access control The Zigbee-based Keypad includes a tag reader and allows for users to enable and disable an alarm system using a pin code and/or an RFID tag. In addition, access data can be updated remotely via a gateway to facilitate access control.
The ZCL “General Function Domain” clusters in this section are implemented as server clusters. Refer to ZigBee Cluster Library Specification. http://www.zigbee.org/Specifications.aspx 4.1.1 Basic – Cluster id 0x0000 Only the first set has mandatory attributes, also the optional attributes that can be relevant to a Develco device are all in set 0x000. 4.1.1.1 Attribute...
Keypad - KEYZB-110 – Technical manual To un-enrol the device the back end system has to write a new address into this attribute. Any value is valid. If the back end system writes an IEEE address then it will try to enrol to this devices represented by the IEEE address.
Keypad - KEYZB-110 – Technical manual 4.2.1.3 Commands The IAS ACE cluster has 3 commands as client server. Name Payload Bits Varies Data Uint8 Enum8 string 0x00 type Field Zone ID Arm Mode Arm/Disarm code name No payload, 0x02 Emergency...
Keypad - KEYZB-110 – Technical manual 4.2.2 Power Configuration - Cluster id 0x0001 The power configuration cluster is described in ZigBee Cluster Library Specification 4.2.2.1 Attribute Name Type Range Man/Opt Relevance and ref. ZCL configure reporting is 0x0020 BatteryVoltage Uint8...
Keypad - KEYZB-110 – Technical manual If it doesn’t find a poll client it will search again periodically. 4.2.4 OTA Upgrade – Cluster id 0x0019 The cluster provides a ZigBee standard way to upgrade devices in the network via OTA messages. The devices support the client side of the cluster.
Keypad - KEYZB-110 – Technical manual 4.2.5 Time – Cluster id 0x000A The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on 1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster.
Keypad - KEYZB-110 – Technical manual 5 MMI user guide Panel description Symbol Function Arm All Zones Disarm Arm Day/Home Zones Only Arm Night/Sleep Zones Only Emergency – Press button for 3 sec Delete last symbol input from keypress Input to Arm/Disarm code “0”...
Keypad - KEYZB-110 – Technical manual Low battery: Yellow LED will blink 2x every 60 second Timeout since last input (5 sec): Yellow LED blink 3x Wrong PIN code: Yellow LED blink 3x Disarm: Green LED solid on for 3 sec...
Keypad - KEYZB-110 – Technical manual 5.2.1 EZ mode - Initiator If the devices is not on the network EZ-Mode Network Steering is invoked when the user enter this menu. The led blinks once every 1 sec until the devices has joined the network. If the device was already on the network it will broadcast the PermitJoin messages.
Keypad - KEYZB-110 – Technical manual 6 General network behaviour Installation When the device is virgin and powered for the first time it will start looking for a ZigBee PAN Coordinator or router to join. The device will scan each ZigBee channel starting from 11 to 24. The LED will flash once every second until it joins a device.
Keypad - KEYZB-110 – Technical manual 7 Specifications General Dimensions (L x B x H) 90 x 90 x 22 mm Colour White – Optional black Battery Battery: 4 x AA Alkaline Battery life 12 Months (Normal usage) Radio Sensitivity: -100 dBm...