TECHNICAL SPECIFICATIONS
Technology:
Radiated frequency:
Radiated power density:
Supply voltage:
to be operated from SELV-compatible
power supplies only
Supply frequency:
Power consumption:
Output
relay contact rating (max. voltage):
relay contact rating (max. current):
Max. switching power:
Wire gauge:
Detection range:
Detection mode:
Output hold time:
Temperature range:
Weight:
IP rating:
Certification:
75.5996.03 MS41 20210421
4.5" SQUARE
MOUNTING BOX COMPATIBILITY
SINGLE-GANG
2 ¾" H × 3 ¼" W ×
" D
15
16
10BOX24SGSM
10ABOXSGSMS
standard, single-gang
electrical box
2
microwave motion sensor
24.125 GHz
< 5 mW/cm
2
12 – 24 VAC ±10%
12 – 24 VDC +30% / -10%
50 – 60 Hz
< 1.5W
relay with switch-over contact (voltage-free)
60 VDC / 125 VAC
1A (resistive)
30W DC / 60 VAC
26 – 22 AWG
4 – 24" (adjustable)
motion (bidirectional)
0.5 – 30 sec
-4 – 131 °F (-20 – 55 °C)
0.34 lbs
IP55
*Apply silicone to sensor housing base to achieve IP65 (see page 4)*
Electromagnetic compatibility (EMC) according to 2004/108/EC
FCC: G9B-210161
IC: 4680A-210161
Specifications are subject to change without prior notice.
All values measured in specific conditions.
Stainless steel, touchless actuator with
adjustable range and relay hold time
DOUBLE-GANG
4 ½" H × 4 ½" W ×
" D
15
16
10BOXDGSM
10BOX475SQSM
1
10BOX45SQSM
1
standard, double-gang
electrical box
2
10BOX45SQFM
1
MS41
6" ROUND
6" ROUND
6" H × 6" W × 1" D
10BOX6RNDSM
1
standard, single-gang
electrical box
2
1. Must use adapter bracket.
2. Not provided by BEA.
Page 1 of 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the MS41 and is the answer not in the manual?

Questions and answers

Summary of Contents for BEA MS41

  • Page 1 FLUSH-MOUNT electrical box electrical box 10BOX45SQFM 1. Must use adapter bracket. 2. Not provided by BEA. TECHNICAL SPECIFICATIONS Technology: microwave motion sensor Radiated frequency: 24.125 GHz Radiated power density: < 5 mW/cm Supply voltage: 12 –...
  • Page 2 You may loosen the cube from the plate on either the top or bottom. Only two snap fittings must be loosened. WIRING Wire the MS41 to the door control according to the 12– 24 VAC/VDC diagram shown here. 12– 24 VAC/VDC NOTE: Use either N.O.
  • Page 3 1. Locate existing 2 wires previously used for the hardwired, mechanical push plate and connect to the MS41 terminals marked 12 – 24 VAC/VDC. 2. Wire to the transmitter's power wires (red and black) with the two MS41 power wires. 3. Wire the transmitter's white wire to COM, and green wire to N.O.
  • Page 4 AUTHORIZATION TO OPERATE THIS EQUIPMENT. BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.