Why is power flashing on inside control board
1 comments:
Mr. Anderson
February 11, 2025
The power may be flashing on the inside control board of the Westinghouse WHS09WMA11S due to incorrect wiring, a loose connection, or voltage fluctuations. To troubleshoot:
1. Check if the units are correctly wired. If not, change the wiring order and test the connection. 2. Inspect for loose connections and fasten them if needed, then verify the connection. 3. Measure the voltage between SI and N using a multimeter. If the voltage does not fluctuate between 0V and 24V, replace the indoor and outdoor control boards.
Page 1
WHS09WMA21S WHS12WMA21S WHS18WMA21S WHS09WMA11S WHS12WMA11S INDOOR WHS24WMA21S WHS30WMA21S WHS36WMA21S WHS09SZA21S WHS18SZA21S WHS24SZA21S WHS09SZA11S WHS12SZA21S OUTDOOR WHS12SZA11S WHS30SZA21S WHS36SZA21S and WESTINGHOUSE are trademarks of Westing house Electric Corporation. Used under license by FUJITSU GENERAL AMERICA, INC. All Rights Reserved. DR_AS126EW_02 2021.01.18...
Page 2
Notices: • Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. WARNING This product can expose you to chemicals including Plumbum, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
1. Specifications Wall mounted Type Inverter heat pump Model name WHS09WMA21S WHS12WMA21S WHS18WMA21S Power supply 208/230 V ~ 60 Hz Power supply intake Outdoor unit Available voltage range 198—253 V 2.64 3.52 5.28 Rated Btu/h 9,000 12,000 18,000 Cooling 1.32—2.93 1.61—3.96 1.90—5.72 Min.—Max.
Page 7
Wall mounted Type Inverter heat pump Model name WHS24WMA21S WHS30WMA21S WHS36WMA21S Power supply 208/230 V ~ 60 Hz Power supply intake Outdoor unit Available voltage range 198—253 V 7.03 8.79 10.26 Rated Btu/h 24,000 30,000 35,000 Cooling 2.34—7.77 3.37—9.81 3.52—10.55 Min.—Max.
Page 8
Wall mounted Type Inverter heat pump Model name WHS09WMA11S WHS12WMA11S Power supply 115 V ~ 60 Hz Power supply intake Outdoor unit Available voltage range 103—127 V 2.64 3.52 Rated Btu/h 9,000 12,000 Cooling 0.35—2.93 0.73—3.96 Min.—Max. Btu/h 1,200—10,000 2,500—13,500 Capacity 2.93...
2-5. Models: WHS30WMA21S and WHS36WMA21S Unit: in (mm) Tube exit Air inlet 2-6. Installation space requirement Provide sufficient installation space for product safety. Distance from ceiling should be over 7.9 in (200 mm) Distance from wall should be over 2 in (50 mm) Distance from wall should be over 2 in (50 mm) Distance from floor should be...
3. Wiring diagrams 3-1. Models: WHS09WMA21S, WHS12WMA21S, and WHS18WMA21S CONTROL UNIT PIPE TEMP. FAN MOTOR ROOM TEMP. OUTDOOR INDOOR UNIT UNIT Temperature 68 F 86 F Thermistor 4.5 k 15 k 6.5 k ( Pipe temp. ) 1.3 V 2.2 V 2.7 V Thermistor 4.5 k...
3-2. Model: WHS24WMA21S OPTIONAL CONTROL UNIT OPTIONAL MOTOR MOTOR LOUVER MOTOR HEAT EXCHANGER DISPLAY UNIT PIPE TEMP OPTIONAL WIRING CONTROL UNIT OR WIFI ROOM TEMP INDOOR OUTDOOR UNIT UNIT Temperature 68 F 86 F Thermistor 15 k 6.5 k 4.5 k ( Pipe temp.
3-3. Model: WHS30WMA21S CONTROL UNIT OPTIONAL LOUVER MOTOR Wifi / Line control LOUVER MOTOR OPTIONAL LOUVER MOTOR OPTIONAL SWITCH UNIT HEAT EXCHANGER DISPLAY UNIT PIPE TEMP OPTIONAL INDOOR OUTDOOR FAN MOTOR UNIT UNIT ROOM TEMP Temperature 68 F 86 F Thermistor 4.5 k 15 k...
3-4. Model: WHS36WMA21S Temperature 68 F 86 F Thermistor 4.5 k 15 k 6.5 k ( Pipe temp. ) 1.3 V 2.2 V 2.7 V Thermistor 4.5 k 15 k 6.5 k ( Room temp. ) 1.3 V 2.2 V 2.7 V Fan motor Pin No.
3-5. Models: WHS09WMA11S and WHS12WMA11S CONTROL UNIT FAN MOTOR WIRING CONTROL UNIT OR WIFI OUTDOOR INDOOR UNIT UNIT Temperature 68 F 86 F Thermistor 15 k 4.5 k 6.5 k ( Pipe temp. ) 1.3 V 2.2 V 2.7 V Thermistor 4.5 k...
4. Capacity table Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 4-1.
4-2. Heating capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. ¢ Model: WHS09WMA21S Indoor temperature °FDB °FWB °FDB °FWB Btu/h 3,845 4,599 7,046 1,079 7,561 1,137 7,871 11,116 1,091 10,768 8,115 5,892 ¢ Model: WHS12WMA21S Indoor temperature °FDB °FWB...
5-2. Wired remote controller a Room temperature sensor A temperature sensor inside the wired remote control switch is set to sense room temperature. b ON/OFF button Starts and stops operation. c MODE selection button Switches operation mode (COOL, DRY, and HEAT). d CLOCK button Activates clock mode (the time flashes on the display) Press...
6. Accessories Part name Q’ty Part name Q’ty Remote controller instructions Drain connector for outdoor unit Use and installation instructions Flare nuts Remote controller Bag of wall anchors and screws Remote controller holder Screw for installations 09/12 model: 1 AAA battery Screw cover 18/24 model: 3 30/36 model: 4...
1. Specifications Type Inverter heat pump Model name WHS09SZA21S WHS12SZA21S WHS18SZA21S Power supply 208/230 V ~ 60 Hz Available voltage range 198—253 V Airflow rate 942 (1,600) 942 (1,600) 1,177 (2,000) CFM (m Type × Q'ty Propeller fan × 1 Motor output dB (A) Sound pressure level *...
Page 27
Type Inverter heat pump Model name WHS24SZA21S WHS30SZA21S WHS36SZA21S Power supply 208/230 V ~ 60 Hz Available voltage range 198—253 V 1,648 2,354 2,354 Airflow rate CFM (m (2,800) (4,000) (4,000) Type × Q'ty Propeller fan × 1 Motor output dB (A) Sound pressure level * 38-3/16 ×...
Page 28
Type Inverter heat pump Model name WHS09SZA11S WHS12SZA11S Power supply 115 V ~ 60 Hz Available voltage range 103—127 V Airflow rate 942 (1,600) CFM (m Type × Q'ty Propeller fan × 1 Motor output dB (A) Sound pressure level * 27-3/8 ×...
3. Installation space 3-1. Models: WHS09SZA21S, WHS12SZA21S, WHS18SZA21S, WHS24SZA21S, WHS30SZA21S, WHS36SZA21S, WHS09SZA11S, and WHS12SZA11S ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
Page 34
Site for installing the indoor unit • Where there is no obstruction near the air outlet and air Indoor unit can be easily blown to every corner. • Where piping and wall hole can be easily arranged. • Keep the required space from the unit to the ceiling and Pipe length: wall according to the diagram on previous page.
5-2. Models: WHS09SZA11S and WHS12SZA11S Fan motor Pin No. Terminal Lead wire Function of terminal code color Compressor 09 model: 2.35 Revolution pulse output Blue 12 model: 1.7 Speed control voltage input Yellow 68 F Control power voltage input White Black Motor power voltage input Temperature...
Need help?
Do you have a question about the WHS09WMA11S and is the answer not in the manual?
Questions and answers
Why is power flashing on inside control board
The power may be flashing on the inside control board of the Westinghouse WHS09WMA11S due to incorrect wiring, a loose connection, or voltage fluctuations. To troubleshoot:
1. Check if the units are correctly wired. If not, change the wiring order and test the connection.
2. Inspect for loose connections and fasten them if needed, then verify the connection.
3. Measure the voltage between SI and N using a multimeter. If the voltage does not fluctuate between 0V and 24V, replace the indoor and outdoor control boards.
This answer is automatically generated